Norgren M/50/LSU/5V Reed-Type Cylinder Magnetic Position Switch

Model Breakdown M/50: 제품 시리즈, cylinder magnetic proximity switch LSU: Reed type, 평상시 열림 (아니요), with LED indicator, 케이블 콘센트 5: 케이블 길이 5 meters V: Universal wide voltage version (10~170V AC/DC) Core Application Detect full stroke position of pneumatic cylinder pistons (extended/retracted position signals for feedback to PLCs or relays) Core Electrical Specifications Parameter ...

  • 제품 세부정보

모델 분석

M/50: 제품 시리즈, cylinder magnetic proximity switch

LSU: Reed type, 평상시 열림 (아니요), with LED indicator, 케이블 콘센트

5: 케이블 길이 5 미터

다섯: Universal wide voltage version (10~170V AC/DC)

핵심 애플리케이션

Detect full stroke position of pneumatic cylinder pistons (extended/retracted position signals for feedback to PLCs or relays)

  1. 핵심 전기 사양
매개변수사양
작동 원리Reed contact (mechanical magnetic actuation)
연락처 구성평상시 열림 (아니요): open without magnet, closed near magnetic ring
작동 전압10~170 V AC/DC; compatible with general 240V AC/DC systems
Max Switching Current0.18 에이
Max Switching Power10 여
응답 시간1.8 ms
표시 등Built-in yellow LED, illuminated upon magnetic actuation
유입 방지IP66 (방진, protected against high-pressure spray)
작동 온도-20 ℃ to +80 ℃
케이블 사양5m PVC cable, 2-core 0.25mm²
규정 준수 표준안에 60947-5-2, RoHS 규제, 도달하다
기원폴란드
  1. 기계 & 설치

3.1 Compatible Cylinders

Norgren RA/8000 and KA/8000 series profile cylinders; matching ring/clamp mounting brackets (QM/33 series), compatible with bore sizes 10/20/25/32/40/50/63/80/100mm.

3.2 장착 방법

Profile T-slot cylinders: Slide switch directly into cylinder T-slot, no extra brackets required

Round tie-rod cylinders: Fixed via optional metal clamp brackets

3.3 하우징 재질

Engineering plastic, resistant to oil contamination and industrial vibration

  1. Cross-Series Selection Guide (Quick Differentiation)
  2. M/50/LSU/2V: 2-meter cable, all other parameters identical to 5V variant
  3. M/50/LSU/5U: 5-meter cable, low-voltage DC model (10~30VDC)
  4. M/50/EHP Series: Electronic solid-state non-contact (PNP/NPN), high-frequency long-life replacement for reed switches
  5. 응용 시나리오

자동화된 조립 라인, 포장 기계, machine tool pneumatic fixtures

Stroke limit detection for material handling cylinders, position sensing for stamping equipment cylinders

Position feedback for general pneumatic actuators, compatible with AC/DC control cabinets

  1. Operating Precautions
  2. Reed contacts cannot drive heavy loads; an interposing relay must be used for signal transfer. Direct driving of solenoid coils is prohibited.
  3. Avoid environments with strong magnetic fields or heavy electromagnetic interference from welding equipment to prevent false triggering.
  4. Minimum cable bending radius ≥ 10× cable outer diameter; corrugated tubing protection recommended for continuously vibrating equipment.
  5. Replace with electronic solid-state M/50 switches if ambient temperature exceeds 80℃.
  6. Part Numbers for Matching Accessories

Clamp bracket for Ø20 bore: QM/33/020/22

Clamp bracket for Ø32 bore: QM/33/432/22

Quick switch retaining clip: QM/27/2/1

IMI Norgren M/50/LSU/5V Reed Magnetic Switch Official Full Installation Manual

Document Basic Information

모델: M/50/LSU/5V (M50LSU5V)

제품 유형: Normally Open reed magnetic position switch, built-in yellow LED, 5m 2-core cable, wide voltage 10~170V AC/DC

Compatible Cylinders: Norgren RA/8000 & KA/8000 series T-slot profile cylinders, round tie-rod cylinders

유입 방지: IP66

표준: 안에 60947-5-2, RoHS 규제, 도달하다

Table of Contents

  1. Unpacking Inspection & 모델 검증
  2. 기계적인 설치 (Two Solutions: T-Slot Profile / Round Tie-Rod Cylinders)
  3. Selection List for Matching Mounting Brackets
  4. 전기 배선 사양 & 배선 다이어그램
  5. Commissioning Procedures
  6. 환경 & 설치 금지 (Critical Restrictions)
  7. 문제 해결 매트릭스
  8. 정기 유지 관리
  9. Quick Reference Technical Specifications

1 Unpacking Inspection & 모델 검증

1.1 Incoming Goods Inspection

  1. Verify laser-engraved model on switch body: M/50/LSU/5V; confirm 5-meter cable length
  2. Inspect housing for cracks, cable root for damage, intact LED viewing window
  3. 부속품: Retaining fixing screw pre-installed on unit; clamp brackets must be ordered separately for round cylinders

1.2 모델 세그먼트 정의

M/50: Magnetic proximity switch series

엘: Equipped with LED indicator

SU: General-purpose reed Normally Open, cable outlet type

5: 5-meter cable length

다섯: Universal wide voltage model, 10~170V AC/DC

2 Mechanical Installation Operating Guide

2.1 T-Slot Profile Cylinders (Norgren RA/KA Series, Recommended Mounting)

  1. Loosen flat-head fixing screw at switch tail and open clip slot
  2. Fully insert switch clip into cylinder side T-slot, slide to target detection position (magnet position at cylinder full extension/retraction)
  3. Fine-tune horizontal position: Optimal trigger point when yellow LED stays steadily illuminated as piston magnet passes switch
  4. Tighten tail fixing screw with flat screwdriver, torque 0.8~1.0 N·m to prevent shifting from vibration
  5. Route cable outlet downward or sideways; upward routing is forbidden to avoid water accumulation

2.2 Round Tie-Rod Cylinders (No T-Slot, Clamp Bracket Mounting)

  1. Select matching QM/33 series metal clamp per cylinder bore size
  2. Fit clamp onto cylinder barrel, pre-tighten clamp screws and slide to detection position
  3. Clip M/50 switch into integrated clamp retainer, fasten switch fixing screw
  4. Fully tighten clamp to prevent sliding during operation; clamp torque 1.2~1.5 N·m

2.3 Mountig Position Standards

Sensing face flush against cylinder outer wall, zero clearance, no metal interlayer

Minimum 20mm spacing between two switches on one cylinder to avoid mutual magnetic interference

Keep clear of strong magnetic inserts on cylinder end caps (buffer magnets)

3 Matching Mounting Bracket Part Number List

Accessory Part No.애플리케이션Compatible Bore Size
QM/27/2/1Universal clip for profile cylinders (identical clip pre-fitted to switch)All T-slot cylinders
QM/33/010/22Aluminum clamp for round cylindersØ10
QM/33/020/22Aluminum clamp for round cylindersØ20/25
QM/33/432/22Aluminum clamp for round cylindersØ32/40
QM/33/463/22Aluminum clamp for round cylindersØ50/63/80/100

4 전기 배선 사양 (Core Chapter)

4.1 Cable Definition (2-core PVC cable, 0.25mm²)

Brown wire (BN): Positive power / AC live line

Blue wire (이것): Negative power / AC neutral line

Internal reed Normally Open contacts close circuit when magnetic ring approaches, yellow LED illuminates

4.2 Two Standard Wiring Schemes

계획 A: Drive PLC Digital Input (가장 일반적인)

  1. DC24V System: BN connected to +24V, BN wired to PLC input terminal, PLC common terminal connected to 0V
  2. AC220V System: BN connected to Live (엘), BU connected to Neutral (N) of PLC AC input module

> WARNING: Max switching current of reed contacts is 0.18A; direct driving of solenoid coils is strictly prohibited!

계획 B: Interposing Relay for Heavy Load Transfer

  1. Relay coil wired in series with BN & BU circuit
  2. Relay contacts control high-current loads including solenoid valves and indicator lights

4.3 Critical Wiring Restrictions

  1. No energization under no-load conditions (unloaded circuit instantly burns reed contacts via electric arcing)
  2. Separate signal wiring from power cables (인버터, motor leads), minimum 10cm spacing to avoid interference-induced false triggering
  3. Minimum cable bending radius ≥10× cable outer diameter; repeated bending/pulling at cable root forbidden
  4. Isolate full cabinet power supply before wiring work to avoid electric shock and contact burnout

4.4 Cable Routing Protection

Vibrating equipment: Route cables through corrugated tubing; reserve 5~8cm slack at switch cable root

Oil mist & spray environments: Wrap cable joints with waterproof tape; seal cable entry points inside control cabinets

5 Standard Full-Unit Commissioning Procedures

단계 1 Mechanical Position Calibration

Manually actuate cylinder piston to slide built-in magnet slowly across switch sensing zone

Magnet at detection position: Yellow LED remains continuously lit

Magnet away from detection position: LED fully off

If LED flickers, fine-adjust switch horizontal position for stable triggering without strobing

단계 2 Electrical Signal Testing

  1. Power on, measure circuit continuity via series-connected multimeter
  2. Magnet in detection zone: Circuit closed (resistance near 0Ω)
  3. Magnet away from detection zone: Circuit open (무한 저항)

단계 3 Automated Cycle Verification

Run cylinder reciprocating cycle 10 times under no-load; confirm stable signal output at every stroke end without signal loss or false triggering

6 환경 & 설치 금지 (Forbidden Operations)

  1. Temperature Limit: Operating range -20℃ ~ +80℃; replace with M/50 electronic switches above 80℃
  2. Magnetic Interference: Keep away from welding equipment, strong permanent magnets, 서보 모터, inverter output cables to prevent false operation
  3. Impact Protection: Prohibit striking or dropping switch unit; internal glass reed tube fractures easily upon impact
  4. Chemical Environments: Install protective covers in strong acid, alkali or high-concentration solvent environments; plastic housing will corrode and crack
  5. Pressure Washing: IP66 rating only resists low-pressure spray; direct high-pressure water jet at cable root causes water ingress and unit failure
  6. Overloaded Operation: Switching power must not exceed 10W; interposing relay mandatory for higher power loads

7 문제 해결 매트릭스

결함 증상근본 원인Stepwise Remedial Actions
LED 꺼짐, no signal when magnet reaches detection point1. Broken/reversed wiring1. Cut power, re-crimp terminals and verify brown/blue wiring
2. Loose/shifted switch mounting2. Tighten fixing screw and recalibrate position
3. Internal reed damage3. Replace with new M/50/LSU/5V unit
Flickering LED, intermittent signal loss1. Excessive gap between switch and magnet1. Mount switch flush against cylinder wall to eliminate clearance
2. 심각한 전자기 간섭2. Route signal cables separately and add shielding
3. Internal wire breakage at cable root3. Trim damaged cable segment and re-terminate
Switch burns out immediately after power-up1. Direct driving of heavy solenoid loads1. Install interposing relay for load transfer
2. Input voltage exceeding 170V2. Match system voltage and add voltage regulator
3. Short-circuit energization under no load3. Series load must be fitted before energizing circuit
Switch slides out of position during cylinder operationInsufficient screw tightening torque, loosening from vibrationRetighten fixing screw to 0.8~1 N路m; add anti-loosening washers for high-vibration machinery

8 Routine Maintenance Specifications

  1. 일일점검: Check LED trigger status, inspect cables for abrasion or cracking
  2. Weekly Maintenance: Clean oil and dust from switch surface; prevent metal debris adhesion to housing
  3. Monthly Inspection: Retorque fixing screws to avoid loosening from long-term vibration
  4. Semi-Annual Calibration: Verify signal stability; maintain spare replacement units for mass production line

9 Core Product Technical Specifications (Installation Reference)

매개변수M/50/LSU/5V Specification
Sensing ElementReed tube, 평상시 열림 (아니요)
작동 전압10~170V AC/DC
Max Switching Current0.18에이
Max Switching Power10여
응답 시간1.8ms
표시 등노란색 LED, illuminated when closed
케이블 사양5중, 2×0.25mm² PVC
유입 방지IP66
작동 온도-20℃ ~ +80℃
하우징 재질난연성 엔지니어링 플라스틱
Compliance Standard안에 60947-5-2

일반적인 결함, 원인 & Remedial Solutions for Norgren M/50/LSU/5V (M50LSU5V) Magnetic Switch

This reed-contact magnetic switch has four primary fault categories: no output signal, flickering signal, burnt switch body, mechanical shifting. Inherent reed switch weaknesses (susceptible to high current, heavy impact and high temperature) are the leading failure triggers.

1 잘못 1: LED unlit, no output signal when cylinder magnet arrives (Most Common Failure)

Potential Causes

  1. Mechanical mounting offset

Loosened fixing screw shifts switch outside magnet sensing zone; excessive gap between switch and cylinder barrel.

  1. Wiring faults

Broken conductors from repeated bending at cable root, loose terminal crimps, cable insulation cut by sharp metal edges leading to short/open circuits (AC/DC polarity insensitive).

  1. Abnormal cylinder magnet

Fallen or demagnetized piston magnet; magnetic field cancellation from two overly closely spaced switches; interference from cylinder buffer magnets.

  1. Physical damage to internal reed tube

Glass reed fractures from impact during transit or installation; permanent reed failure under prolonged temperatures above 80℃.

  1. Mismatched supply voltage

Input voltage exceeds rated 170V, burning internal components.

교정 조치

  1. Slide switch back to magnet center position, 나사를 조이세요 (0.8~1 N·m torque) and mount flush against cylinder wall without gaps.
  2. Cut power and test cable continuity; trim damaged cable sections and re-crimp terminals; reserve slack at cable root for strain relief.
  3. Replace cylinder piston magnet; maintain ≥20mm spacing between two switches and keep clear of end cap buffer magnets.
  4. Reed fractures require full unit replacement; electronic M/50/EHP switches recommended for high-temperature environments (minor faults repairable under low-temperature conditions).
  5. Restrict system voltage within 10~170V AC/DC; fit voltage stabilizers for overvoltage systems.

2 잘못 2: Flickering LED, intermittent signals, frequent PLC false stroke detection / signal loss

Potential Causes

  1. Loose switch mounting creates minor shifting from equipment vibration, unstable magnet detection.
  2. 심각한 전자기 간섭: Signal cables routed in the same trunking as motor, inverter and welding power cables.
  3. Degraded magnet strength narrows effective sensing range, causing flickering at threshold positions.
  4. Partial internal cable conductor breakage creating intermittent open/closed circuits under mechanical strain.
  5. External permanent magnets or tooling magnets counteract cylinder piston magnetic fields.

교정 조치

  1. 고정 나사를 다시 조이세요; install anti-loosening washers for high-vibration equipment.
  2. Run signal cables in separate conduits with minimum 10cm separation from power cables.
  3. Replace cylinder built-in piston magnet.
  4. Cut off damaged cable segment and re-terminate; relocate unit away from external permanent magnets.

3 잘못 3: Switch burns out immediately upon power-up, zero functionality after energization

Core Root Cause (Fatal Mistake for Reed Switches)

  1. Direct driving of solenoid valves or heavy relay coils

Unit maximum switching power only 10W / 0.18에이; inductive surge current from solenoid coils instantly punctures reed contacts.

  1. Energization with no load in circuit, contact burnout from instantaneous electric arcing.
  2. Continuous contact arcing from frequent switching under AC220V operation causes contact welding and erosion.
  3. Cable positive-negative short-circuit; heavy current burns internal LED and reed tube.

교정 조치

  1. Mandatory interposing relay for signal transfer: Switch only energizes relay coil; relay contacts control solenoid valves.
  2. Never energize unloaded circuits; series load must be installed before power connection.
  3. Replace with non-contact electronic M/50/EHP switches (PNP/NPN, zero arc wear) for high-frequency switching applications.
  4. Locate cable insulation short-circuit points and reinforce insulation protection.

4 잘못 4: 접촉용접, LED permanently lit after magnet moves away, signal fails to cut off

원인

  1. Long-term overload and inductive load arcing melts reed contacts together.
  2. Contact metal fatigue and welding from frequent cycling combined with high ambient temperature.
  3. Excess supply voltage amplifies arcing and accelerates contact fusion.

교정 조치

Welded reed contacts cannot be repaired; replace entire switch unit. Fit interposing relays downstream to eliminate contact arcing.

5 잘못 5: Automatic sliding shift of switch during long equipment operation

원인

  1. Insufficient tightening torque on fixing screws.
  2. Continuous vibration and shock from production line operation.
  3. Worn T-slot retaining clips reducing clamping force.

교정 조치

Retighten screws to standard torque; add anti-loosening washers for vibrating equipment; replace complete switch unit if retaining clips are worn.

6 Latent Failures Induced by Operating Environment

  1. High-temperature environments (>80℃)

Rapid decline in reed sensitivity leading to failed triggering and drastically shortened service life; permanent unit failure under sustained high heat.

  1. Immersion in oil mist or cutting fluid

IP66 rating only resists spray exposure; prolonged liquid penetration at cable root causes internal oxidation and wire breakage.

  1. Corrosive chemical vapors

Plastic housing ages and cracks, moisture ingress damages reed tube and LED assembly.

7 Quick Differentiation: Reed Switch Exclusive Faults vs Electronic Switch Faults

M50LSU5V reed model unique failure modes: 접촉용접, burnout from electric arcing, vulnerability to high current surges, internal damage from impact shock.

Electronic M/50/EHP switches contain no moving mechanical contacts and eliminate all above faults, suited for high-frequency and high-power load applications.

Simplified On-Site Quick Troubleshooting Workflow

  1. Manually cycle cylinder and observe synchronized LED on/off status to isolate mechanical positioning or magnet faults.
  2. Cut power and test cable continuity with multimeter to identify broken wiring.
  3. Disconnect downstream loads and test switch independently to diagnose overload burnout.
  4. Re-route wiring away from inverters and motors to eliminate electromagnetic interference.