위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

Schneider Acti9 Series A9I48191V120H1P-100A - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

회로 차단기/

Schneider Acti9 Series A9I48191V120H1P-100A

ItemSpecification Parameter
Brand and SeriesSchneider Acti9 Series
Product Type1-pole Disconnector (speculative)
정격 작동 전압120뷔와 (North American voltage class)
정격 작동 전류100에이
Pole Number1-pole
Core FunctionCircuit isolation, no-load switching
응용 시나리오Power isolation and maintenance power-off in single-phase 120V power distribution systems in North America

  • 제품 세부정보

Model A9I48191V120H1P-100A

Model A9I48191V120H1P-100A is the complete order number of a low-voltage electrical product under the Acti9 Series of 슈나이더 일렉트릭. The meaning of each segment of the code and the corresponding product attributes can be explained as follows:

  1. Model Segment Analysis
  2. A9: Represents the major product series, namely Schneider’s Acti9 Series. This series is a standardized low-voltage component series launched by Schneider for terminal power distribution, covering miniature circuit breakers, 잔류 전류 장치, disconnectors, and other products.
  3. I48: Represents the product type sub-code. In combination with the naming rules of the Acti9 Series, this code usually refers to disconnectors or fuse-disconnectors, which are mainly designed for no-load switching of circuits and power isolation.
  4. 191: Represents the structural characteristics and accessory configuration code. Different number combinations correspond to different installation methods (예를 들어, DIN rail mounting), operation methods (예를 들어, handle operation), or auxiliary contact configurations.
  5. V120: Represents the rated working voltage parameter of the product. Here, `V120` indicates that the rated working voltage of the product is suitable for 120V AC circuits. It should be noted that this voltage class is common in the North American market and is incompatible with the mainstream 220V/380V voltage system in China.
  6. H1P: Represents the pole number and installation specification of the product. `H1P` means a 1-pole product, suitable for the isolation requirements of single-phase circuits.
  7. 100에이: Represents the rated working current of the product, i.e., the maximum current that the component can carry stably for a long time is 100A.
  8. Summary of Core Product Attributes
ItemSpecification Parameter
Brand and SeriesSchneider Acti9 Series
Product Type1-pole Disconnector (speculative)
정격 작동 전압120뷔와 (North American voltage class)
정격 작동 전류100에이
Pole Number1-pole
Core FunctionCircuit isolation, no-load switching
응용 시나리오Power isolation and maintenance power-off in single-phase 120V power distribution systems in North America
  1. Key Precautions
  2. Voltage Compatibility: The rated voltage of this product is 120V AC. It is strictly prohibited to use it directly in domestic 220V AC circuits, 그렇지 않으면, it may cause safety accidents such as component burnout and insulation breakdown.
  3. Functional Positioning: Disconnectors do not have short-circuit protection or overload protection functions and are only used for circuit isolation. They must be used in conjunction with protective components such as circuit breakers.
  4. Model Verification: To confirm accurate product drawings, installation dimensions, and technical manuals, you can enter the complete order number through Schneider’s official product selection tool or technical support hotline for inquiry.

Domestic Voltage-Adaptable Model Comparison Table for Schneider Acti9 Series 100A Disconnectors

The following is a complete comparison table of domestic adaptable models corresponding to the North American model A9I48191V120H1P-100A and models with different pole numbers of the same specification. These models are suitable for the mainstream 230/400V AC voltage system in China and meet the isolation requirements of single-phase/three-phase power distribution systems.

  1. Core Model Correspondence
North American Original ModelDomestic Adaptable ModelProduct SeriesPole NumberRated Voltage정격전류Product Type
A9I48191V120H1P-100AA9S70690 (iSW Series) / A9S66191Acti91P230/400뷔와100에이Miniature Disconnector
A9I48191V120H1P-100AA9S71690 (iSW Series)Acti91P230/400뷔와100에이Disconnector with Auxiliary Contacts
A9I48191V120H1P-100AiINT125 1P 100AActi91P230/400뷔와100에이Terminal Disconnector
  1. Complete Table of Domestic Adaptable Models with Different Pole Numbers of the Same Specification
Pole NumberDomestic Standard ModelProduct SeriesRated Voltage정격전류Module WidthCore Features일반적인 애플리케이션 시나리오
1PA9S70690 (iSW)Acti9230/400뷔와100에이2 modules (18mm)Basic disconnector without auxiliary contactsIsolation of single-phase circuits, such as residential incoming lines and power isolation of small equipment
1PA9S66191 (iSW)Acti9230/400뷔와100에이2 modules (18mm)Standard disconnector with red operating handleSingle-phase power distribution in commercial buildings, maintenance isolation
1PiINT125 1P 100AActi9230/400뷔와100에이2 modules (18mm)Terminal-specific with optimized operating mechanismDC-side isolation of photovoltaic systems, front-end of small UPS
2PA9S70790 (iSW)Acti9230/400뷔와100에이4 modules (36mm)2-pole interlock, simultaneous isolation of live wire and neutral wireSingle-phase 2-pole circuits, such as high-power household appliances like air conditioners and water heaters
2PA9S66291 (iSW)Acti9230/400뷔와100에이4 modules (36mm)Standard 2-pole with red handlePower isolation of commercial kitchen equipment and small air compressors
3PA9S70890 (iSW)Acti9400뷔와100에이6 modules (54mm)3-pole interlock, three-phase isolationFront-end of three-phase equipment such as motors, 물 펌프, and fans
3PA9S66391 (iSW)Acti9400뷔와100에이6 modules (54mm)Standard 3-pole with high short-circuit withstand capacityIndustrial automation equipment, main switch of small power distribution cabinets
4PA9S70990 (iSW)Acti9400뷔와100에이8 modules (72mm)4-pole interlock, three-phase + neutral wire isolationUPS input/output in data centers, isolation of medical equipment
4PA9S66491 (iSW)Acti9400뷔와100에이8 modules (72mm)Standard 4-pole with locking deviceThree-phase power distribution in special industries such as chemical and metallurgical industries
  1. Key Adaptation Instructions
  2. Voltage Compatibility: All domestic models are suitable for 230/400V AC (50/60헤르츠), fully compatible with the domestic power grid. It is strictly prohibited to directly use North American 120V models in domestic 220V/380V systems.
  3. Functional Consistency: All domestic models retain the core functions of disconnectors—no-load circuit switching and power isolation. They do not have short-circuit or overload protection capabilities and must be used in conjunction with circuit breakers.
  4. Installation Compatibility: All models adopt 35mm DIN standard rail mounting, consistent with the installation method of the original North American model, enabling direct replacement and installation.
  5. 선택 권장 사항:

For single-phase circuits, prioritize 1P/2P models.

For three-phase power circuits, prioritize 3P models.

For critical loads requiring simultaneous neutral wire isolation (such as medical equipment and data centers), select 4P models.

For applications requiring remote status monitoring, select models with auxiliary contacts such as A9S71690.

  1. Supplementary Information
ItemDetailed Description
Certification StandardComplies with IEC 60947-3 그리고 GB 14048.3 표준, holding domestic CCC certification
Operating LifeMechanical life ≥ 10,000 times; Electrical life ≥ 1,000 times (no-load operation)
TerminalSuitable for 16~25mm² copper conductors, recommended torque: 8~10N·m
보호 등급IP20, suitable for installation inside power distribution cabinets