Overview: The ATV71HU55N4Z is a general-purpose inverter of Schneider‘s Altivar 71 series, with a rating of 5.5kW/7.5HP, compatible with 380-480V three-phase power supply. It features a built-in EMC filter and Modbus/CANopen communication, without a graphic terminal, and is suitable for constant torque loads. This model has been discontinued, and the ATV340 or ATV930 series are recommended as replacements.
- Full Model Interpretation
| Model Segment | Meaning |
| ATV71 | Altivar 71 series high-performance inverter |
| H | Standard coating, IP20 protection class, wall-mounted installation |
| U55 | Rated for 5.5kW motor power |
| N4 | 380-480V three-phase power supply, 50/60헤르츠 |
| Z | Built-in EMC filter, no graphic terminal, with Modbus and CANopen communication |
- 핵심 기술 매개변수
| 매개변수 항목 | 값 |
| Rated Power | 5.5kW (7.5HP) |
| Input Voltage | 380-480V three-phase, allowable fluctuation -15%~+10% |
| Output Current | 14.3에이 (400다섯), 17에이 (480다섯), 20.3에이 (380다섯) |
| Control Modes | V/f control, sensorless flux vector control, closed-loop vector control (encoder required) |
| Communication Interfaces | Built-in Modbus and CANopen, supports various expansion cards (Profibus DP, DeviceNet, 등.) |
| Integrated Functions | Standard STO safety function (ISO 13849 PL e), PID regulator, brake control, over 150 built-in functions |
| EMC Class | Built-in Class A EMC filter, compliant with EN 55011 standard |
| 보호 등급 | IP20 (external cabinet protection required) |
| Dimensions & 무게 | Approx. 210*380*190mm, approx. 8kg |
- 제품특징 & Advantages
- High Dynamic Performance: Achieves 100% rated torque at zero speed (150% rated torque) output under closed-loop vector control, suitable for high-demand scenarios such as hoisting and lifting.
- Comprehensive Safety Integration: Standard STO (Safe Torque Off) function, no additional modules required for safety circuit construction.
- Flexible Communication Expansion: Plug-in communication cards compatible with mainstream industrial fieldbuses, enabling seamless interconnection with Siemens, Rockwell, Omron PLCs.
- Robust and Durable Design: Standard coating for resistance to harsh industrial environments, with comprehensive protection mechanisms for over-temperature, over-voltage, over-load, 등.
- Easy Operation & Maintenance: Optional graphic terminal, “Easy Start” menu, parameter protection, and intuitive fault diagnosis.
- 일반적인 애플리케이션 시나리오
The ATV71 series is designed exclusively for constant torque loads. Typical applications of ATV71HU55N4Z include:
Hoisting and lifting equipment (crane, elevator, winch)
Material conveying systems (belt conveyor, chain conveyor)
Packaging machinery, woodworking machinery, wood-based panel equipment
Process control equipment, mixers, compressors and other constant torque loads
Start-up and speed control of high-inertia loads
- Discontinuation & Replacement Solutions
The ATV71 series has been discontinued, and Schneider officially recommends the following replacement paths:
5.1 Schneider Original Replacements
First Choice: ATV340U55N4 (5.5kW, 380-480다섯, built-in EMC, Modbus/CANopen)
Heavy-Duty/Complex Applications: ATV930U55N4 (higher performance and richer functions)
Key Replacement Notes: Match power, voltage, control mode, 통신 요구 사항, safety functions and installation method.
5.2 Cross-Brand Replacement Recommendations
| Brand | Recommended Model | Key Matching Points |
| 지멘스 | MM440-5.5kW/380-480V | Constant torque control, built-in EMC, Modbus |
| 씨줄 | ACS550-01-12A6-4 | 5.5kW, IP20, built-in EMC filter |
| Mitsubishi | FR-A840-00122-2-60 | 5.5kW, 380-480다섯, vector control |
| Rockwell | PowerFlex 525-5.5kW | Built-in EMC, multiple communication protocols |
- Selection & Replacement Notes
- Load Type Matching: Confirm the load is constant torque; for variable torque loads (fans/water pumps), economical series such as ATV610 are recommended.
- Accessory Compatibility: Original ATV71 I/O expansion cards, encoder interface cards, 등., may need to be replaced with models adapted to the new series.
- Parameter Migration: Use Schneider’s parameter conversion tool to ensure correct migration of key parameters (예를 들어, acceleration/deceleration time, torque limit, PID parameters).
- Safety Functions: The STO function of the new series needs to be reconfigured to meet the safety class requirements of the original system.
- Installation Space: The dimensions of ATV340/ATV930 are slightly different from ATV71; confirm the installation space is compatible.
Schneider ATV71HU55N4Z Replacement Models
Overview: The ATV340U55N4 (general/economical) is the first choice for original factory replacement, and ATV930U55N4 (high-performance/full-function) is for heavy-duty/complex applications; cross-brand options include 5.5kW models of the same specification such as Siemens MM440, ABB ACS550, Mitsubishi FR-A840, and Rockwell PowerFlex 525.
- Official Original Factory Replacement Solutions (Schneider Recommended)
The ATV71 series has been discontinued, and Schneider officially provides two core replacement paths:
1.1 Standard Replacement (First Choice): ATV340U55N4 (Altivar Machine Series)
| 매개변수 항목 | ATV71HU55N4Z | ATV340U55N4 | 호환성 |
| Power/Voltage | 5.5kW/380-480V three-phase | 5.5kW/380-480V three-phase | 100% |
| Control Modes | V/f, sensorless vector, closed-loop vector | V/f, sensorless vector, closed-loop vector (standard encoder interface) | 100% |
| Communication Interfaces | Built-in Modbus, CANopen | Built-in Modbus, CANopen, optional EtherNet/IP | Upgraded |
| EMC Filter | Built-in Class A | Built-in Class A | 100% |
| Safety Functions | STO (PL e) | STO (PL e) + optional SS1 | Upgraded |
| 보호 등급 | IP20 | IP20 (IP42 with optional cover) | 100% |
| Dimensions & 무게 | 210*380*190mm/8kg | 200*360*180mm/7.5kg | Compatible |
| Advantages | Mature and stable | More compact, energy-efficient, highly integrated, cost-effective | – |
적용 가능한 시나리오: Constant torque loads such as general machinery, material conveying, and packaging equipment, pursuing a balance between cost performance and functions.
1.2 High-Performance Replacement: ATV930U55N4 (Altivar Process Series)
| 매개변수 항목 | ATV71HU55N4Z | ATV930U55N4 | 호환성 |
| Power/Voltage | 5.5kW/380-480V three-phase | 5.5kW/380-480V three-phase | 100% |
| Control Modes | Basic vector control | Advanced vector control + synchronous motor control + servo functions | Upgraded |
| Communication Interfaces | Basic communication | Built-in Modbus, CANopen, optional EtherNet/IP, Profinet | Fully Upgraded |
| Expansion Capability | Limited expansion | Supports more I/O, safety and communication expansion modules | Upgraded |
| Safety Functions | STO | STO+SS1+SLS+SBC (complete safety package) | Fully Upgraded |
| 보호 등급 | IP20 | IP20/IP21 (optional) | Enhanced |
| Dimensions & 무게 | 210*380*190mm/8kg | 220*400*200mm/9kg | Compatible |
| Advantages | Mature and stable | 산업 4.0 integration, advanced diagnosis, predictive maintenance | – |
적용 가능한 시나리오: High-demand applications such as hoisting, lifting and high-precision positioning, requiring advanced safety functions and communication capabilities.
1.3 Special Application Replacements
Fan/Water Pump Applications: ATV610U55N4 (Altivar Process Series, optimized for variable torque, higher energy efficiency)
Explosion-Proof Environment: ATV340U55N4 + explosion-proof enclosure (certification required)
Ultra-Compact Installation: ATV320U55N4 (miniaturized design, simplified function version)
- Cross-Brand Replacement Model Recommendations (5.5kW/380-480V, Same Specification)
| Brand | Recommended Model | Core Matching Points | Remarks |
| 지멘스 | MM440-5.5kW/380-480V (6SE6440-2UD25-5CA1) | Constant torque control, built-in EMC, Modbus communication | Classic general-purpose model with sufficient spare parts |
| 씨줄 | ACS550-01-12A6-4 | 5.5kW, IP20, built-in EMC filter | Suitable for harsh environments with strong overload capacity |
| Mitsubishi | FR-A840-00122-2-60 | Vector control, 380-480다섯, built-in brake unit | Representative of Japanese performance with convenient debugging |
| Rockwell | PowerFlex 525-5.5kW (25B-D017N114) | Built-in EMC, multiple communication protocols, safety functions | Suitable for Rockwell automation system integration |
| Omron | 3G3RX-A4055-ZV2 | 5.5kW, vector control, Modbus/CANopen | Miniaturized design with high cost performance |
| Danfoss | VLT 2800-5.5kW (132F0015) | Built-in EMC, easy to use, energy-saving mode | Suitable for small machinery applications |
- Key Replacement Notes
3.1 Load Type Matching
Confirm the original load is constant torque (the design target of ATV71); for variable torque loads (fans/water pumps), it is recommended to use the ATV610 series for higher efficiency.
For heavy-duty applications (예를 들어, hoisting), ATV930 or heavy-duty inverters of other brands must be selected to ensure 150% torque output capacity.
3.2 Key Parameter Migration Points
Key parameters: Acceleration/deceleration time, torque limit, PID parameters, motor nameplate data (must be re-entered).
Communication settings: Modbus address, baud rate and data format must be consistent with the original system.
Safety functions: STO parameters need to be reconfigured to meet the safety class requirements of the original system (ISO 13849 PL e).
3.3 Hardware Compatibility
Installation Dimensions: ATV340 is slightly smaller and ATV930 is slightly larger than ATV71; confirm the installation space is compatible.
터미널 레이아웃: The terminal positions of the new series have changed, requiring rewiring.
Accessory Adaptation: Original ATV71 I/O expansion cards and communication cards cannot be directly used for ATV340/930 and need to be replaced with corresponding models.
3.4 Utilization of Function Upgrades
ATV340/930 are equipped with a standard encoder interface (optional for ATV71), enabling higher precision control.
The new series supports industrial Ethernet such as EtherNet/IP, facilitating system upgrade to Industry 4.0.
Enhanced diagnostic functions can early warn of faults and reduce downtime.
- Recommended Replacement Implementation Steps
4.1 Preparations
Record all parameters of the original ATV71 (backup with Schneider SoMove software is recommended).
Confirm motor nameplate data (power, voltage, 현재의, speed, pole number).
Evaluate load characteristics (constant torque/variable torque, starting torque requirements, braking needs).
4.2 Selection Confirmation
Select ATV340 or ATV930 series according to the application scenario.
Confirm accessory requirements (communication expansion card, brake resistor, filter, 등.).
4.3 Installation & Commissioning
Install the new inverter with power off and ensure correct wiring (pay special attention to phase sequence).
Enter motor parameters and perform auto-tuning (mandatory step).
Migrate key control parameters and test basic operation.
Verify communication connection and safety functions.
Conduct load test and adjust parameters to the optimal state.