위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

Schneider Electric ComPacT NSX160N - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

전기 같은/회로 차단기/

Schneider Electric ComPacT NSX160N

Schneider Electric’s ComPacT NSX160N is a high-performance Molded Case Circuit Breaker (MCCB), primarily used for overload protection, 단락 보호, and isolation functions in low-voltage power distribution systems. Basic Parameters and Design Frame Current: 160에이 (adjustable range: 112-160에이) Breaking Capacity: Class N (50그만큼), suitable for 380-415V AC systems; up to 90kA at 220V, and reduced to 10kA at ...

  • 제품 세부정보

Schneider Electric’s ComPacT NSX160N is a high-performance Molded Case Circuit Breaker (MCCB), primarily used for overload protection, 단락 보호, and isolation functions in low-voltage power distribution systems.

  1. Basic Parameters and Design

Frame Current: 160에이 (adjustable range: 112-160에이)

Breaking Capacity: Class N (50그만큼), suitable for 380-415V AC systems; up to 90kA at 220V, and reduced to 10kA at 690V

Pole Number: 3P or 4P (In the 4P model, the neutral wire (N) is located on the left; the 3D design indicates that the N wire is not involved in protection)

Rated Voltage: 690뷔와 (50/60헤르츠), meeting the power distribution needs of most industrial and commercial applications

Trip Unit Type: TMD (Thermomagnetic Trip Unit), providing overload (엘) and short-circuit (I) protection, including:

과부하 보호 (Ir): Adjustable range of 0.7-1×In (160에이)

단락 보호 (Ii): Fixed value of 1250A (약 7.8 정격 전류의 배)

  1. Structure and Installation

설치 방법: Supports fixed, plug-in, and withdrawable mounting, enabling flexible adaptation to different cabinet designs

전체 치수:

4P model: Width 140mm × Height 161mm × Depth 86mm, weight 2.6kg

3P model: The width may be narrower (105mm according to some data), and confirmation is required based on the specific model

Connection Method: Front connection design, with a terminal spacing of 35mm, supporting horizontal or vertical installation

III. Functions and Certifications

Protection Functions:

Basic type: Provides long-time overload (엘) and instantaneous short-circuit (I) protection, complying with the IEC 60947-2 standard

Optional expansion: Leakage protection, undervoltage tripping, remote control (예를 들어, MX/MN coils) can be realized by adding modules

절연 기능: Complies with the EN/IEC 60947-2 standard and can be used as an isolator

환경 적응성:

Operating temperature: -25°C ~ +70°C, humidity ≤95% (결로가 없을 것)

Certifications: CCC, EAC, Marine certifications, suitable for industrial, 광고, and marine environments

  1. 응용 시나리오

Power Distribution Systems: Used as a main switch or branch switch to protect circuits for motors, 조명, and mixed loads

Industrial Control: Cooperates with devices such as contactors and relays to build automatic control circuits

Renewable Energy: Suitable for overcurrent protection in distributed generation systems such as solar energy and wind energy

  1. Replacement and Upgrading

Replacement Models: For higher breaking capacity, NSX160H (70그만큼) or NSX160L (100그만큼) can be selected

Digital Upgrading: The new generation of ComPacT NSX series (예를 들어, NSX160N-D) supports the EcoStruxure Power architecture and can integrate functions such as wireless monitoring, energy metering, and service life prediction

  1. 선택 권장 사항
  2. Current Matching: Calculate the rated current (In) based on the load, and ensure that the trip unit setting covers the normal operating current
  3. Breaking Capacity: Select the breaking capacity class (N/H/L) according to the short-circuit current level at the installation location
  4. Accessory Expansion:

보조 연락처 (OF): Used to indicate the status of the circuit breaker

Motorized Operating Mechanism (MT): Enables remote switching on and off

Leakage Module (Vigi NSX): Provides residual current protection

Ⅶ. 지침

설치사양: Must comply with IEC 60947-2 and local electrical installation standards, and ensure that the terminal torque meets the requirements

Maintenance Recommendations: Regularly inspect the contact wear condition; clean the arc-extinguishing chamber and test the tripping characteristics every 2-3 연령