3RV1374-7GN10|SIEMENS SIRIUS High‑Performance Motor Protection Circuit‑Breaker (MPCB)

Full Model: 3RV1374-7GN10 (Siemens SIRIUS 3RV1 series, moulded case circuit‑breaker with enhanced breaking capacity for starter combinations)

상표: Siemens SIRIUS Industrial Control Series

  1. Detailed Model Breakdown
Model Part의미Key Description
3RV1시리즈SIRIUS 3RV1 series, moulded case motor protection circuit‑breaker, designed with enhanced breaking capacity for starter combinations
374SizeLarge size, rated current 400A, suitable for 200kW three‑phase motors at 400V
7Breaking Capacity ClassEnhanced breaking capacity, up to 200kA@400V
G여행 유형Electronic trip unit, short‑circuit protection adjustable from 1–10 × In
NConnection나사 터미널, with phase barriers for safe and reliable connection
10Number of Poles3 극 (3P3d), for three‑phase motor protection circuits
  1. Core Technical Data
사양Notes
Rated Operational Current (In)400에이 (fixed)For 200kW three‑phase induction motors at 400V
정격전압 (Ue)690뷔와For medium‑high voltage industrial motor control systems
정격 절연 전압 (우이)1000뷔와Higher than operating voltage, large safety margin
Ultimate Breaking Capacity (중환자실)200kA@400VEnhanced breaking capacity for heavy short‑circuit faults
Poles3 극 (3P3d)Standard three‑phase motor protection
Trip CharacteristicMagnetic only (short‑circuit protection only)Electronic trip, short‑circuit adjustable 1–10×In; must be used with overload relay
OperationRotary ON/OFF actuatorManual control, simple and clear
MountingPanel mountingSuitable for control cabinet integration
Degree of ProtectionIP30Standard for switchgear installation
Applicable StandardIEC 60947‑4‑1International standard for motor protection devices
  1. Key Features & Applications

Main Advantages

  1. Ultra‑high breaking capacity: 200kA@400V, withstands heavy short‑circuit faults in industrial networks
  2. Precise protection: Electronic trip with adjustable short‑circuit protection for various motor starting characteristics
  3. Reliable connection: Screw terminals with phase barriers to prevent phase‑to‑phase short circuits
  4. System integration: Designed for starter combinations, works perfectly with contactors and overload relays
  5. Durable design: Industrial‑grade quality, suitable for harsh environments and long mechanical life

일반적인 응용 분야

Large industrial motor control centers (MCC), 400V/690V systems

Short‑circuit protection for three‑phase induction motors up to 200kW at 400V (must be used with overload relay)

High‑power motor protection in metallurgy, mining, paper and other heavy industries

Large continuous‑duty equipment: 압축기, 팬, pumps

Main drive motors in production lines with frequent starting and fluctuating loads

  1. Replacement Models

Upgrades / Replacements (Same Brand)

모델Key Data특징Application
3VA2240‑0MS32‑0AA0400에이, 200kA@400V, 3피, electronic tripUpgrade replacement for 3RV1, new 3VA2 series MCCBNew projects requiring higher performance and communication
3RV1374‑7KN10400에이, 200kA@400V, 3피, electronic tripDifferent terminal configurationSame rating, different connection requirements
3RV1374‑7GN20400에이, 200kA@400V, 4피, electronic trip4‑pole version with neutral protectionThree‑phase four‑wire systems needing neutral protection

Cross‑Brand Alternatives

상표모델Matching Specifications
씨줄Tmax T4H 400 PR221DS400에이, 100kA breaking, electronic trip, 3피
슈나이더TeSys GV4‑ME400400에이, 100kA breaking, thermal‑magnetic trip, 3피
MitsubishiNF400‑SEW400에이, 100kA breaking, electronic trip, 3피
  1. Protection coordination: This unit provides magnetic only (short‑circuit) protection and must be used with an overload relay (e.g. 3RU series) for complete motor protection.
  2. Breaking capacity matching: Selected based on system short‑circuit calculation; 200kA suits most industrial grids.
  3. 배선: Screw terminals for copper/aluminum cables; observe cross‑section and torque specifications.
  4. Mounting space: Large frame size requires sufficient cabinet space.
  5. Upgrade recommendation: Some 3RV1 models are discontinued; 3VA2 series is recommended for new projects for advanced protection and communication.
  6. Accessories: 보조 접점, alarm contacts available for motor status monitoring and control.

이전:

답장을 남겨주세요

메시지를 남겨주세요