Chint NXBLE63 – 2P/C40 is a 2 – pole (2P) miniature residual current circuit breaker. Its main parameters and functions are as follows: Core Parameters Rated Current: 40A (“C40” indicates that the tripping characteristic is Type C and the rated current is 40A); Pole Number: 2P (cuts off both the live wire and the neutral wire ...

  • Product Details

Chint NXBLE63 – 2P/C40 is a 2 – pole (2P) miniature residual current circuit breaker. Its main parameters and functions are as follows:

Core Parameters

Rated Current: 40A (“C40” indicates that the tripping characteristic is Type C and the rated current is 40A);

Pole Number: 2P (cuts off both the live wire and the neutral wire simultaneously);

Residual Current Protection: AC type (detects ordinary AC leakage). The residual operating current is usually 30mA (an industry conventional value, and some models support options such as 50mA/75mA);

Breaking Capacity: 6kA (can safely cut off circuits with a short – circuit current of not less than 6000A);

Applicable Voltage: 230V (for single – phase circuits);

Mechanical/Electrical Life: The mechanical life is 20,000 times, and the electrical life is 10,000 times.

Main Functions

  1. Residual Current Protection: When there is electric shock to the human body (current ≥ 30mA) or equipment leakage in the circuit, the power supply is quickly cut off within 0.1 second to prevent electric shock casualties;
  2. Overload Protection: If the circuit load is too large (current exceeds 40A), it will automatically disconnect to avoid overheating and fire of the circuit;
  3. Short – Circuit Protection: When a short circuit occurs in the circuit (current increases sharply in an instant), the circuit is cut off immediately to protect electrical appliances and the circuit;
  4. Isolation Function: It can be used as a switch for infrequent on – off of the circuit under normal conditions.

Application Scenarios

Household Electricity: For high – power socket circuits in kitchens, living rooms, etc. (such as air conditioners, electric water heaters), it replaces traditional air switches and adds residual current protection;

Small – scale Commercial Places: For socket or lighting circuits in convenience stores and offices, meeting the electricity demand within 40A;

Decoration and Renovation: Upgrading the residual current protection of old circuits to meet the new national standard’s requirement that “socket circuits must be equipped with residual current protection”.

Installation and Use Precautions

– It should be selected according to the actual load of the circuit to avoid “a big horse pulling a small cart” or “a small horse pulling a big cart”;

– Press the “test button (T key)” once a month to verify whether the residual current protection function is normal;

– When installing, the live wire (L) and the neutral wire (N) must be distinguished. If the wiring is reversed, the residual current protection function may fail.