Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Complete Model List of SCHNEIDER iC65N Series - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

NotíciasNotícias comerciais

Complete Model List of SCHNEIDER iC65N Series

Schneider iC65N is a standard miniature circuit breaker in the Acti9 series, with a breaking capacity of 6 o, complying with IEC 60898-1/GB 10963.1 padrões. It is suitable for power distribution protection in residential, comercial, e aplicações industriais leves.

  1. Model Naming Rules

iC65N [Número de poloneses] [Curva de tropeço] [Corrente nominal]

iC65N: Basic model (6 capacidade de interrupção kA)

Número de poloneses: 1P, 1P+N, 2P, 3P, 3P+N, 4P

Curva de tropeço: B (3-5Em), C (5-10Em), D (10-14Em)

Corrente nominal: 1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UM

Order Code Example: A9F18106 = iC65N 1P C6A

  1. Complete Model Classification
  2. Classification by Number of Poles

1P (Single Pole)

Curva de tropeçoCorrente nominalModeloOrder Code
Curve B1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 1P B[Em]A9F181B[Em]
Curve C1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 1P C[Em]A9F181C[Em]
Curve D10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 1P D[Em]A9F191D[Em]

1P+N (Single Pole + Neutral)

Curva de tropeçoCorrente nominalModeloOrder Code
Curve C1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 1P+N C[Em]A9F185C[Em]
Curve D10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 1P+N D[Em]A9F195D[Em]

2P (Two Poles)

Curva de tropeçoCorrente nominalModeloOrder Code
Curve B1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 2P B[Em]A9F182B[Em]
Curve C1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 2P C[Em]A9F182C[Em]
Curve D10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 2P D[Em]A9F192D[Em]

3P (Three Poles)

Curva de tropeçoCorrente nominalModeloOrder Code
Curve B1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 3P B[Em]A9F183B[Em]
Curve C1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 3P C[Em]A9F183C[Em]
Curve D10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 3P D[Em]A9F193D[Em]

3P+N (Three Poles + Neutral)

Curva de tropeçoCorrente nominalModeloOrder Code
Curve C1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 3P+N C[Em]A9F187C[Em]
Curve D10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 3P+N D[Em]A9F197D[Em]

4P (Four Poles)

Curva de tropeçoCorrente nominalModeloOrder Code
Curve B1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 4P B[Em]A9F184B[Em]
Curve C1UM, 2UM, 3UM, 4UM, 6UM, 10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 4P C[Em]A9F184C[Em]
Curve D10UM, 16UM, 20UM, 25UM, 32UM, 40UM, 50UM, 63UMiC65N 4P D[Em]A9F194D[Em]
  1. Series Features & Selection Guide
  2. Parâmetros técnicos principais

Tensão nominal: 1P AC 230 V, 2P/3P/4P AC 400 V

Tensão nominal de isolamento: 600 V

Quebrando Capacidade: 6 o (exclusive to iC65N series)

Características de disparo: Three curves B/C/D for different load types

Curve B: For resistive loads (por exemplo, iluminação)

Curve C: For general power distribution and motor control (most common)

Curve D: For high inductive loads and transformer protection

Protection Degree: IP40 (front), IP20 (terminais)

Temperatura ambiente: -35℃ ~ +70 ℃

  1. Cenários de aplicação

Power distribution protection for residential and commercial buildings

Control circuits for small industrial equipment

Protection for lighting, condicionadores de ar, bombas de água, etc..

Replacement of traditional fuses, providing both overload and short‑circuit protection

  1. Series Comparison (iC65 Family)
SérieQuebrando CapacidadeApplicationOrder Code Prefix
iC65N6 oStandard applications, cost‑effectiveA9F18/A9F19
iC65H10 oIndustrial environments, higher breaking requirementsA9I28/A9I29
iC65L15 oSpecial industrial applications, high short‑circuit riskA9L28/A9L29
  1. Common Model Examples
ModeloOrder CodeMain Application
iC65N 1P C16AA9F18116Residential lighting circuit protection
iC65N 2P C20AA9F18220Small air conditioner / water heater protection
iC65N 3P C32AA9F18332Three‑phase motor control circuit
iC65N 4P D50AA9F19450Primary protection for small transformers
iC65N 1P+N C25AA9F18525Commercial lighting system protection

The Schneider iC65N series covers all pole configurations from 1P to 4P, full current ratings from 1A to 63A, and is equipped with B/C/D tripping curves, meeting most low‑voltage power distribution protection requirements.

Select the appropriate model based on load type, requisitos de pólo, and short‑circuit breaking capacity. Curve C is preferred for standard applications.

Anterior:

Próximo:

Deixe uma resposta