Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Schneider Electric MCB A9P52606 - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

NotíciasNotícias comerciais

Schneider Electric MCB A9P52606

Schneider Electric A9P52606 is a disjuntor miniatura (MCB) of the Acti9 iC40 series, featuring 1P+N pole configuration, 6A rated current, and C-type tripping curve. It is designed for overload and short-circuit protection of conventional distribution circuits such as lighting and socket systems, with a rated breaking capacity of 6kA (IEC 60947‑2)/4.5o (EM 60898). It adopts DIN rail mounting and has an IP20 protection rating.

  1. Interpretação do modelo
ItemDetails
ModeloA9P52606
SérieActi9 iC40
TypeDisjuntor Miniatura (MCB)
Configuração do Pólo1P+N (1 protective pole, N pole for switching only)
Corrente nominal6UM
Curva de tropeçoTipo C
Quebrando Capacidade6o (IEC 60947‑2), 4.5o (EN 60898‑1)
Mounting MethodDIN Rail
Protection RatingIP20
  1. Parâmetros técnicos principais
ParâmetroValuePadrão
Rated Operational Voltage (Ué)230Vca 50/60 HzEN/IEC 60947‑2
Corrente nominal (Em)6UMEN/IEC 60947‑2
Característica de disparoTipo C (instantaneous tripping at 5In‑10In)EN/IEC 60898‑1
Ultimate Breaking Capacity (UTI)6o (230V e)EN/IEC 60947‑2
Service Breaking Capacity (Icn)4.5o (230V e)EN/IEC 60898‑1
Tensão nominal suportável ao impulso (Uimp)4kVEN/IEC 60947‑2
Overvoltage CategoryEN/IEC 60947‑2
Grau de poluição3EN/IEC 60947‑2
Temperatura operacional-25℃~70℃EN/IEC 60947‑2
Vida Elétrica20,000 operaçõesEN/IEC 60947‑2
Vida Mecânica20,000 operaçõesEN/IEC 60947‑2
Dimensões (W×D×H)1 módulo (18milímetros) × 44mm × 91mmSchneider Electric Technical Manual
Neutral Pole PositionLeft SideSchneider Electric Technical Manual
Tripping Unit TypeThermal-magneticSchneider Electric Technical Manual
  1. Recursos funcionais
  2. 1P+N Design: Live wire protection plus synchronous neutral wire switching, suitable for single-phase distribution systems, with clear wiring and convenient maintenance.
  3. Type C Tripping Curve: Suitable for conventional loads such as lighting and sockets, balancing overload time-delay and short-circuit instantaneous tripping, with strong resistance to inrush current.
  4. High Breaking Capacity: 6o (IEC 60947‑2)/4.5o (EN 60898‑1), capable of handling severe short-circuit faults and ensuring distribution safety.
  5. Standard Mounting: DIN rail mounting with 1-module width, saving switchgear space, and compatible with Acti9 series accessories (por exemplo, contatos auxiliares, contatos de alarme).
  6. Adaptabilidade Ambiental: IP20 protection rating, resistant to temperatures ranging from -25℃ to 70℃, meeting the requirements of industrial and civil distribution environments.
  7. Application Scope

Overload and short-circuit protection for single-phase distribution circuits of lighting, sockets, small motors, etc., in commercial buildings and industrial plants.

Places with high requirements for power supply reliability, such as office buildings, hotéis, and hospitals.

Compatible with Acti9 series distribution boxes, used in scenarios such as terminal power distribution and branch circuit protection.

  1. Recomendações de seleção
  2. Load Matching: Type C curve is suitable for non-inductive loads (por exemplo, iluminação, sockets); avoid selecting Type D (for power loads) or Type B (for electronic equipment) curves.
  3. Circuit Matching: With a rated current of 6A, it is suitable for 1.5mm² copper core cables (long-term current-carrying capacity ≥ 10A), and the circuit length should be ≤ 100m.
  4. Quebrando Capacidade: The 6kA breaking capacity is suitable for terminal distribution; the front-end should be equipped with molded case circuit breakers with higher breaking capacity (por exemplo, 15kA and above).
  5. Seleção de acessórios: According to monitoring requirements, select accessories such as auxiliary contacts (por exemplo, A9A26924) and alarm contacts (por exemplo, A9A26934).
  6. Solução de problemas
Fenômeno de falhaPossíveis causasTroubleshooting Methods
Viagens frequentesSobrecarga, line grounding/short-circuit, mismatched tripping curveCheck load current and insulation resistance; replace MCB with a matching tripping curve
Failure to CloseUnreset tripping mechanism, line short-circuit, contact ablationManually reset the trip lever, locate the short-circuit point, replace damaged contacts
Excessive Temperature RiseLoose wiring, contact oxidation, high ambient temperatureTighten wiring terminals, polish contacts, improve ventilation and heat dissipation
Insufficient Breaking CapacityLack of front-end protection, excessive short-circuit current in the lineUpgrade front-end protection, select MCB with higher breaking capacity
  1. Soluções Alternativas

Intra-series Alternatives: A9P52610 (1P+N, 10UM, Tipo C), A9P52616 (1P+N, 16UM, Tipo C), etc., maintaining mounting and accessory compatibility.

Cross-series Alternatives: Schneider Electric IDPN series (por exemplo, A9D18606, 1P+N, 6UM, Tipo C) or ABB S200 series (por exemplo, S201M‑C6, 1P+N, 6UM, Tipo C). It is necessary to verify the matching of mounting dimensions and breaking capacity.

Complete Guide to Other Models of Schneider Electric Acti9 iC40 Series

Schneider Electric Acti9 iC40 series is a miniature circuit breaker (MCB) specially designed for single-phase/three-phase distribution systems. With 1P+N as the core product, it also provides multiple pole configurations including 2P, 3P, 4P, and 3P+N. The tripping curves cover Type B/C/D, and the breaking capacity is divided into standard type (4.5kA Icn/6kA Icu) and Type N (6kA Icn/10kA Icu), with rated current covering the full range of 1A~63A. The following is a structured and complete list of models:

  1. Model Naming Rules (A9PXXXXXX)
PositionCodeSignificado
1-2A9Acti9 Series Identifier
3PExclusive Code for iC40 Series
42-4Quebrando Capacidade: 2 = Standard Type (4.5kA/6kA), 4 = Type N (6kA/10kA)
56/2/3/4/7Configuração do Pólo: 6 = 1P+N, 2 = 2P, 3 = 3P, 4 = 4P, 7 = 3P+N
6-701~63Corrente nominal: 01 = 1A, 02 = 2A, 04 = 4A, 06 = 6A, 10 = 10A, 16 = 16A, 20 = 20A, 25 = 25A, 32 = 32A, 40 = 40A, 50 = 50A, 63 = 63A
Curve IdentifierB/C/D: Tipo B (3In-5In), Tipo C (5In-10In), Tipo D (10In-14In)
  1. Classified List of Full Series Models
  2. 1P+N (Most Commonly Used)
    Curva de tropeçoQuebrando CapacidadeCorrente nominalModelo
    Tipo BTipo padrão2A/4A/6A/10A/16A/20A/25A/32A/40AA9P22602/A9P22604/A9P22606/A9P22610/A9P22616/A9P22620/A9P22625/A9P22632/A9P22640
    Type N2A/4A/6A/10A/16A/20A/25A/32A/40AA9P42602/A9P42604/A9P42606/A9P42610/A9P42616/A9P42620/A9P42625/A9P42632/A9P42640
    Tipo CTipo padrão2A/4A/6A/10A/16A/20A/25A/32A/40A/50A/63AA9P22602/A9P22604/A9P52606/A9P22610/A9P22616/A9P22620/A9P22625/A9P22632/A9P22640/A9P22650/A9P22663
    Type N2A/4A/6A/10A/16A/20A/25A/32A/40A/50A/63AA9P42602/A9P42604/A9P54606/A9P42610/A9P42616/A9P42620/A9P42625/A9P42632/A9P42640/A9P42650/A9P42663
    Tipo DTipo padrão10A/16A/20A/25A/32A/40A/50A/63AA9P62610/A9P62616/A9P62620/A9P62625/A9P62632/A9P62640/A9P62650/A9P62663
    Type N10A/16A/20A/25A/32A/40A/50A/63AA9P64610/A9P64616/A9P64620/A9P64625/A9P64632/A9P64640/A9P64650/A9P64663

    2P (Two-pole)

Curva de tropeçoQuebrando CapacidadeCorrente nominalModelo
Tipo CTipo padrão6A/10A/16A/20A/25A/32A/40AA9P52206/A9P52210/A9P52216/A9P52220/A9P52225/A9P52232/A9P52240
Type N6A/10A/16A/20A/25A/32A/40AA9P54206/A9P54210/A9P54216/A9P54220/A9P54225/A9P54232/A9P54240
Tipo DTipo padrão16A/20A/32A/40AA9P62216/A9P62220/A9P62232/A9P62240
Type N16A/20A/32A/40AA9P64216/A9P64220/A9P64232/A9P64240
  1. 3P (Three-pole)
Curva de tropeçoQuebrando CapacidadeCorrente nominalModelo
Tipo CTipo padrão6A/10A/16A/20A/25A/32A/40AA9P52306/A9P52310/A9P52316/A9P52320/A9P52325/A9P52332/A9P52340
Type N6A/10A/16A/20A/25A/32A/40AA9P54306/A9P54310/A9P54316/A9P54320/A9P54325/A9P54332/A9P54340
Tipo DTipo padrão16A/20A/32A/40A/50AA9P62316/A9P62320/A9P62332/A9P62340/A9P62350
Type N16A/20A/32A/40A/50AA9P64316/A9P64320/A9P64332/A9P64340/A9P64350
  1. 4P (Four-pole)
Curva de tropeçoQuebrando CapacidadeCorrente nominalModelo
Tipo CTipo padrão6A/10A/16A/20A/32A/40AA9P52406/A9P52410/A9P52416/A9P52420/A9P52432/A9P52440
Type N6A/10A/16A/20A/32A/40AA9P54406/A9P54410/A9P54416/A9P54420/A9P54432/A9P54440
  1. 3P+N (Three-pole + Neutral)
Curva de tropeçoQuebrando CapacidadeCorrente nominalModelo
Tipo CTipo padrão16A/20A/32A/40AA9P52716/A9P52720/A9P52732/A9P52740
Type N16A/20A/32A/40AA9P54716/A9P54720/A9P54732/A9P54740
Tipo DTipo padrão20A/32A/40AA9P62720/A9P62732/A9P62740
Type N20A/32A/40AA9P64720/A9P64732/A9P64740
  1. Key Features and Selection Points
  2. Principais vantagens:

1P+N Design: Live wire protection plus synchronous neutral wire switching, suitable for 230V single-phase systems, saving installation space (1 module = 18mm).

Graded Breaking Capacity: Standard type is suitable for terminal distribution, while Type N is suitable for front-end circuits close to distribution transformers.

Tripping Curve Adaptability: Tipo B (for electronic equipment), Tipo C (for lighting/sockets), Tipo D (for motors/power loads).

  1. Comparison with the Original Model:

The model you queried: A9P52606: 1P+N, 6UM, Tipo C, standard breaking capacity (4.5kA/6kA).

Upgraded Type N version: A9P54606 (breaking capacity upgraded to 6kA/10kA).

Same current with different curves: A9P42606 (Tipo B), A9P62606 (Tipo D).

  1. Compatibilidade de acessórios: The full series is compatible with Acti9 standard accessories, como contatos auxiliares (A9A26924) and alarm contacts (A9A26934).
  2. Cenários típicos de aplicação
Model ExampleApplication Scenario
A9P52606 (1P+N, 6UM, Tipo C)Residential/commercial lighting circuits, sockets for small electronic devices
A9P54616 (1P+N, 16UM, Tipo C, Type N)Kitchen appliances, air conditioner sockets (requiring higher breaking capacity)
A9P64232 (2P, 32UM, Tipo D, Type N)Power equipment such as single-phase water pumps and compressors
A9P54340 (3P, 40UM, Tipo C, Type N)Industrial equipment such as three-phase fans and small air compressors

 

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado