ABB PSTX300-600-70 Soft Starter - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

ABB PSTX300-600-70 Soft Starter - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

ŞtiriȘtiri comerciale

ABB PSTX300-600-70 Soft Starter

300O, 600V, 3-phase integrated bypass soft starter from ABB’s PSTX series, providing smooth motor starting and stopping as well as comprehensive motor protection

Parametri cheie: Rated current 300A (AC-53b), rated voltage 208–600V AC, control voltage 100–240V AC, protocoale de comunicare: Modbus, EtherNet/IP, BACnet

Funcții de bază: Voltage ramp / torque control start, current limit (standard / dual / ramp), soft stop, integrated bypass contactor, full-featured motor protection

Certificari: Conform IEC/EN 60947-4-2, UL 508, CSA C22.2 No. 14, CE, CCC

  1. Model Number Explanation
CodeDescriere
PSTXABB advanced smart soft starter series
300Rated operational current: 300O (continuous current under AC‑53b)
600Tensiune nominală de funcționare: 600V (applicable range: 208–600V AC)
70Control voltage range: 100–240V AC (universal for 50/60Hz)
  1. Complete Technical Specifications
CategorieDetalii
Electric• Rated operational current (AC‑53b): 300O
• Rated operational voltage (Ue): 208–600V AC
• Phase: 3
• Control voltage (Us): 100–240V AC (50/60Hz)
• Compatible power: 160kW (400V), 200HP (460V)
• Starting method: Soft start/stop with integrated bypass
• Breaking capacity: 50cel (600V)
• Overload capacity: 1.1×In (continuous at 40°C)
• Starting current limit: 3 modes (standard / dual / ramp), up to 3.5×In
Mechanical & Environmental• Ingress protection: IP00
• Mounting: DIN rail / bolt mounting
• Operating temperature: ‑25°C to +60°C
• Storage temperature: ‑40°C to +80°C
• Relative humidity: 5–95% (non‑condensing)
• Dimensions (W×H×D): 250×368×190mm
• Weight: aproximativ. 12kg
Caracteristici• 3‑phase fully controlled thyristor control with integrated bypass contactor (reduces power consumption)
• Multiple starting modes: voltage ramp, controlul cuplului, current limit
• Soft stop function (prevents water hammer, ideal for pump loads)
15 motor protection functions: suprasarcina, locked rotor, phase loss, phase imbalance, earth fault, etc.
• Modular design, supports DIN rail and door mounting
• Graphic display with 4‑key operation, supports remote monitoring and parameter setting
  1. Key Advantages
  2. Integrated bypass design: Automatically switches to bypass contactor after startup, lowers operating power consumption (≤1.5W) and extends thyristor service life
  3. Flexible communication: Built-in Modbus RTU/TCP, EtherNet/IP, BACnet for easy integration into industrial networks
  4. Comprehensive protection: Full motor, short-circuit and overload protection in compliance with IEC 60947-4-2
  5. Wide voltage compatibility: 208–600V AC universal input, globally applicable for complex grid conditions
  6. User-friendly operation: Removable HMI panel supports door mounting; status reading and parameter adjustment without shutdown
  7. Detailed Applications

4.1 Tratarea apei & Fluid Handling

Large pump control: Centrifugal / axial / mixed flow pumps in municipal water supply and wastewater treatment plants; soft stop prevents water hammer and reduces pipeline pressure shock

Submersible sewage pumps: Reduces mechanical stress during startup, avoids cavitation and reverse flow impact, improves system reliability

Chemical process pumps: Smooth startup for high-viscosity fluid pumps, minimizes mechanical seal wear and extends service life

4.2 Fabricarea & Material Handling

Compressor systems: Smooth startup for air and refrigeration compressors, reduces grid impact and prevents belt slippage

Crushers / grinders: Heavy-duty crushing equipment in mining and building materials; current-limited startup controls mechanical shock and protects drive systems

Conveyor systems: Long-distance belt conveyors; smooth acceleration avoids material spillage and reduces belt tension stress

Mixers / agitators: Mixers in food and pharmaceutical industries; torque-controlled startup ensures process stability

4.3 Building & Infrastructură

sisteme HVAC: Large fans (cooling towers, air conditioning units) and pumps; soft starting reduces impact on building power grids

Metro / tunnel ventilation: Synchronous soft starting of multiple high-power fans to avoid interference with lighting and signaling systems

Fire pumps: Main and backup pumps in emergency fire systems; ensures reliable startup in compliance with fire safety codes

4.4 Special Industrial Applications

Pulp & paper: Vacuum / pressure fans for paper machines; smooth startup protects precision drive systems

Oilfield production: Pumping units and water injection pumps; adapts to harsh field environments and improves equipment reliability

Port machinery: Auxiliary motors for cranes and handling equipment; soft starting protects hydraulic systems

  1. Cross-Reference for International Brand Equivalents
MarcaSerieModelParametri cheieCapacitate de rupereOrder Code
SchneiderATS48ATS48D32Q320O, 208–600V, 100–240V control50celATS48D32Q
Siemens3RW553RW5546‑6HA14300O, 208–690V, 24V control50cel3RW5546‑6HA14
EatonDMXDMX300S600300O, 208–600V, 100–240V control50celDMX300S600
RockwellSMC‑50SMC‑50‑300A‑1300O, 208–600V, 100–240V control50cel150‑S300NBD
ABBPSTPST300‑600‑70300O, 208–600V, 100–240V control50celPST300‑600‑70
  1. Complete ABB PSTX Series Model List (Standard Order Codes)

The PSTX series is available in various rated currents for different motor powers. Core models are listed below:

Curent nominalModelStandard Order CodeCompatible Power (400V)Compatible Power (460V)
30OPSTX30‑600‑701SFA898104R700015kW20HP
37OPSTX37‑600‑701SFA898105R700018.5kW25HP
45OPSTX45‑600‑701SFA898106R700022kW30HP
60OPSTX60‑600‑701SFA898107R700030kW40HP
72OPSTX72‑600‑701SFA898108R700037kW50HP
85OPSTX85‑600‑701SFA898109R700045kW60HP
105OPSTX105‑600‑701SFA898110R700055kW75HP
142OPSTX142‑600‑701SFA898111R700075kW100HP
170OPSTX170‑600‑701SFA898112R700090kW125HP
210OPSTX210‑600‑701SFA898113R7000110kW150HP
300OPSTX300‑600‑701SFA898114R7000160kW200HP
370OPSTX370‑600‑701SFA898115R7000200kW250HP
470OPSTX470‑600‑701SFA898116R7000250kW350HP
570OPSTX570‑600‑701SFA898117R7000315kW400HP
720OPSTX720‑600‑701SFA898118R7000400kW500HP
840OPSTX840‑600‑701SFA898119R7000450kW600HP
  1. Selecţie & Application Notes
  2. Potrivirea încărcării: 300A fits 160kW motors at 400V and 200HP motors at 460V. Consider load type (fan / pump / compressor) and starting conditions during selection
  3. Installation notes: Montare standard pe șină DIN de 35 mm; keep ≥50mm clearance above and below for heat dissipation; vertical installation recommended
  4. Communication setup: Modbus RTU supported by default; EtherNet/IP or BACnet can be enabled via parameter settings
  5. Protection configuration: Set overload curve, locked rotor protection, phase loss protection, etc., according to motor parameters to ensure safe operation
  6. Replacement selection: Match rated current, voltage range, control voltage and protection functions when replacing; prefer equivalent advanced smart soft starters

Unsuitable Applications

Applications requiring variable frequency speed control (ABB ACS series drives recommended)

Special voltage systems below 100V or above 600V

Outdoor / humid environments requiring IP20 or higher protection (protected version or enclosure required)

Key Differences Between ABB PSTX300-600-70-1 and PSTX300-600-70

  1. Official Model Definition & Order Codes

Model standard: PSTX300-600-70, official order code: 1SFA898114R7000

Model with suffix-1: PSTX300-600-70-1, typically corresponds to 1SFA898114R7001 (special configuration version)

  1. Core Differences
ArticolPSTX300‑600‑70 (Standard)PSTX300‑600‑70‑1 (‑1 Version)
Control voltage100–240V AC (50/60Hz universal)24În DC (DC control supply)
Suffix meaning“70” indicates standard AC control voltage“‑1” typically indicates 24V DC control version
AplicațieGeneral industrial and commercial use, standard AC control circuitsSuitable for safety circuits, Control PLC, DC control systems and other low‑voltage control applications
CommunicationIdentic: built‑in Modbus RTU/TCP, EtherNet/IP, BACnetIdentic
Core ratingsIdentic: 300O, 600V, integrated bypass, operating temp up to 60°CIdentic
Physical dimensionsIdentic: 250×368×190mm, 12kg, 35mm DIN rail mountIdentic
  1. Detailed Description
  2. Control voltage difference: This is the fundamental distinction. The standard version uses 100–240V AC control power, while the-1 version uses 24V DC to suit different control system power supplies
  3. Configuration positioning: The “-1” suffix in ABB soft starter naming generally denotes a 24V DC control version, designed for integration with PLC, DCS and other DC control systems, or safety applications requiring electrical isolation between control and main circuits
  4. Functional consistency: Except for control voltage, all core functions are identical:

300A rated operational current, suitable for 160kW (400V) / 200HP (460V) motoare

3-phase fully controlled thyristor control with integrated bypass contactor (operating power ≤1.5W)

Multiple starting modes: voltage ramp, controlul cuplului, current limit

15 motor protection functions: suprasarcina, locked rotor, phase loss, phase imbalance, earth fault, etc.

Removable graphic HMI panel with 15 language support

  1. Recomandări de selecție
  2. Control supply matching: Select standard version for AC control systems and-1 version for DC control systems
  3. Safety requirements: For safety applications requiring isolation between control and main circuits, the 24V DC-1 version is preferred
  4. Spare parts management: Distinguish between the two models to avoid failure due to control voltage mismatch
  5. Replacement compatibility: Identical mounting, communication and protection features; interchangeable with appropriate control power supply (subject to system compatibility check)

The only substantive difference between ABB PSTX300-600-70-1 and PSTX300-600-70 is the control voltage: standard version is 100–240V AC, while the-1 version is 24V DC. All other core parameters, functions and physical dimensions are identical. Selection should be based on control system power type and safety requirements.