Releu de protecție multifuncțional Siemens seria 7UM62

Releu de protecție multifuncțional Siemens seria 7UM62

  1. Detailed Model Coding Rules for 7UM62 Series
  2. Siemens product information PDF şi information on alternative brands in China

The Siemens SIPROTEC 4 7UM62 series uses a 12-digit segmented structure. The complete coding format is:

Segment de codDescriereStandard OptionsObservații
7UM62Seria de produse7UM62SIPROTEC 4 multifunctional protection for generators, motors and transformers
[Function Version]Protection Function Scope11=StandardDetermines protection logic and available algorithms
12=Enhanced
13=Full (Generator‑dedicated)
[Housing Type]Dimensiuni & I/O Quantity1=1/2 19″, 7BI, 12BO, 1 readyDefines I/O capacity and display type
2=1/1 19″, 15BI, 20BO, 1 ready
3=Graphic display, 1/2 19″, 7BI, 12BO
[Tip terminal]Connection TerminalB=Screw terminalB for fixed installation; E for frequent replacement
E=Plug‑in terminal (2/3‑pin)
[CT Rating]CT Ratio & SensibilitateB=5A standardMatches on‑site CT for accurate measurement
E=1A standard
H=1A high‑sensitivity (IEE)
L=5A low‑sensitivity
[Region/Standard]Standard & LanguageA=Germany, 50Hz, IEC, GermanDefines protection curves and HMI language
B=Global, 50/60Hz, IEC/ANSI, engleză (UK)
C=USA, 60Hz, ANSI, engleză (US)
D=Customized
[Special Function]Additional Function0AA0=BasicSpecial functions require separate authorization
0HA0=With communication
0AC0=Enhanced event recording
0FA0=With synchrocheck
  1. Complete Model Matrix of 7UM62 Series (Grouped by Configuration)

2.1 Standard Function Version (7UM6211)

Model completComanda nr.Configurație de bazăAplicație
7UM6211-1BB02-0AA07UM6211-1BB02-0AA01/2 19″, 7BI/12BO, screw, 5A CT, globalăSmall/medium motor protection, general industry
7UM6211-1EB01-0HA07UM6211-1EB01-0HA01/2 19″, 7BI/12BO, plug‑in, 1A CT, with commsDistributed control systems, frequent maintenance
7UM6211-2BB02-0AA07UM6211-2BB02-0AA01/1 19″, 15BI/20BO, screw, 5A CT, globalăLarge motors/transformers, complex logic
7UM6211-2EB91-0AA07UM6211-2EB91-0AA01/1 19″, 15BI/20BO, plug‑in, 1A CT, customizedCritical power equipment, custom protection
7UM6211-3BB02-0HA07UM6211-3BB02-0HA01/2 19″, graphic display, 7BI/12BO, screw, 5A CT, with commsImportant equipment with local monitoring

2.2 Enhanced Function Version (7UM6212)

Model completComanda nr.Configurație de bazăEnhanced Functions
7UM6212-1EB01-0AC07UM6212-1EB01-0AC01/2 19″, 7BI/12BO, plug‑in, 1A CT, event recordingFault recording, analiza armonică
7UM6212-2BB02-0FA07UM6212-2BB02-0FA01/1 19″, 15BI/20BO, screw, 5A CT, synchrocheckGrid‑parallel operation, out‑of‑sync prevention
7UM6212-3EB01-0HA07UM6212-3EB01-0HA01/2 19″, graphic display, 7BI/12BO, plug‑in, 1A CT, with commsGraphic UI + advanced comms for smart substations

2.3 Full Function Version (7UM6213) – Generator Dedicated

Model completComanda nr.Configurație de bazăGenerator Protection Features
7UM6213-2EB22-0HA07UM6213-2EB22-0HA01/1 19″, 15BI/20BO, plug‑in, 1A CT, with comms100% stator earth fault, rotor earth fault protection
7UM6213-1BB02-0AA07UM6213-1BB02-0AA01/2 19″, 7BI/12BO, screw, 5A CT, globalăSmall hydro & captive power generators
7UM6213-3EB91-0AC07UM6213-3EB91-0AC01/2 19″, graphic display, 7BI/12BO, plug‑in, 1A CT, event recordingGraphic fault analysis for large generators

2.4 Special Configurations (by CT & Region)

CT TypeRegion SettingTypical ModelsApplication Features
5A StandardGlobal (IEC/ANSI)7UM6211-1BB02-0AA0Most industrial power systems
7UM6211-2BB02-0AA0
1A StandardSTATELE UNITE ALE AMERICII (ANSI)7UM6211-1EB01-0CA0Standard for North American power systems
7UM6211-2EB01-0CA0
1A High‑SensitivityGlobal (IEC/ANSI)7UM6211-1EH01-0HA0High‑impedance earthing systems, improved earth fault detection
7UM6211-2EH01-0HA0
5A Low‑SensitivityEurope (IEC)7UM6211-1BL02-0AA0High‑capacity equipment, reduced maloperation
7UM6211-2BL02-0AA0
  1. Funcții de bază & Specificatii tehnice

3.1 General Technical Data

ArticolValoareDescriere
Measuring Channels8×Current, 4×VoltageFull monitoring for three‑phase systems
Sampling Rate24 samples/cycleAccurate transient capture, high reliability
ComunicareRS485 standard, Ethernet opționalSupports IEC 60870‑5‑103, Modbus, etc.
Tensiune de alimentare110/220V AC/DCWide‑range design
Temperatura ambiantă-25℃ ~ +70℃Industrial and outdoor installation
Protection DegreeIP30For panel mounting

3.2 Funcții de protecție de bază

Integrated comprehensive protection (varies by version):

Protecție la supracurent (ANSI 50/51)

Impedance protection (ANSI 21)

Out-of-step protection (ANSI 78)

Over/undervoltage (ANSI 59/27)

Over/underfrequency (ANSI 81)

Stator/rotor earth fault (ANSI 64)

Reverse power (ANSI 32)

Synchrocheck (ANSI 25)

  1. Selecţie & Ordering Notes
  2. Function Version

Standard (11): Motoare generale & transformatoare

Îmbunătățit (12): Advanced monitoring & event analysis

Deplin (13): Generator-specific, inclusiv 100% stator earth fault

  1. Locuințe & I/O

1/2 19″ (7BI/12BO): Space-limited panels

1/1 19″ (15BI/20BO): Complex logic, more I/O

Graphic display (3xx): Local operation & diagnosticarea defecțiunii

  1. CT Matching

Confirm on-site CT ratio (5A/1A)

High-sensitivity versions for high-impedance earthing

  1. Region & Standard

Global (B): IEC/ANSI compliant, ideal for export

Regional (A/C): Optimized for local standards

  1. Replacement Models

7UM62 series is discontinued; recommended successor: 7UM85 series (SIPROTEC 5)

Cross-brand alternatives: ABB REF615, Schneider Sepam 80 serie, ABB RET670 (generator-dedicated)