Întrerupător de protecție a pornirii motorului Chint NS2-25/4-6.3A - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

întrerupător de circuit/

Întrerupător de protecție a pornirii motorului Chint NS2-25/4-6.3A

Element de parametruCaietul de sarcini
Tensiune nominală de izolație690V
Tensiune nominală de lucruAC 230/240V, 400/415V, 440V, 500V, 690V
Rated Frequency50/60Hz
Setting Current Range4~6.3A
Instantaneous Electromagnetic Trip Current78O (aproximativ 12 times the setting current)
Capacitatea de rupere în scurtcircuitIcu=100kA, Ics=7.5kA (at AC400V)
Clasa de protectieIP20 (front side)
Operating Frequency≤30 times/hour
Applicable Ambient Temperature-5℃~+40℃
GreutateApproximately 313g

  • Detalii despre produs

Chint NS2-25/4-6.3A is a starter protection switch specifically designed for three-phase squirrel-cage induction motors. It integrates the functions of a întrerupător de circuit and a thermal relay, providing overload protection, phase failure protection, protectie la scurtcircuit, and infrequent starting control.

Interpretarea modelului:

NS2: Cod de serie (N stands for Chint, S stands for Starter)

25: Frame current rating (25O)

4-6.3O: Rated current range of the trip unit (adjustable within 4-6.3A)

  1. Parametrii tehnici de bază
Element de parametruCaietul de sarcini
Tensiune nominală de izolație690V
Tensiune nominală de lucruAC 230/240V, 400/415V, 440V, 500V, 690V
Rated Frequency50/60Hz
Setting Current Range4~6.3A
Instantaneous Electromagnetic Trip Current78O (aproximativ 12 times the setting current)
Capacitatea de rupere în scurtcircuitIcu=100kA, Ics=7.5kA (at AC400V)
Clasa de protectieIP20 (front side)
Operating Frequency≤30 times/hour
Applicable Ambient Temperature-5℃~+40℃
GreutateApproximately 313g

III. Caracteristici funcționale

  1. Funcții multiple de protecție

Protecție la suprasarcină: Built-in bimetallic thermal element acts when the current exceeds the setting current for a certain period, preventing motor burnout due to overheating.

Phase Failure Protection: Detects the loss of any phase in the three-phase power supply and immediately cuts off the circuit to protect the motor.

Protecție la scurtcircuit: Instantaneous electromagnetic trip unit operates rapidly (≤100ms) when the current reaches 78A, preventing the expansion of short-circuit faults.

Funcția de izolare: Can be used as an isolating switch to ensure maintenance safety.

  1. Funcții de control

Integrates start/stop button control with a compact structure.

Supports 35mm standard DIN rail mounting for quick deployment.

Optional accessories available: Undervoltage Trip (UV), Shunt Trip (SH), Auxiliary Contact (AE/AU), Fault Signal Contact (FA).

  1. Scenarii de aplicare

NS2-25/4-6.3A is suitable for:

Protection and control of three-phase induction motors with a power of approximately 2.2kW (400V).

Control of small and medium-sized motors in factories and workshops, such as fans, pompe de apa, conveyors, compresoare, și alte echipamente.

Motor control cabinets in building automation systems.

Can replace the traditional circuit breaker + thermal relay combination scheme, saving space and costs.

  1. Precauții de utilizare
  2. Cerințe de instalare

Install vertically with an inclination angle ≤±5° to ensure reliable operation.

The tightening torque for the terminal screws (M4) is 1.7N·m; avoid over-tightening to prevent thread damage.

Recommended wire cross-sectional area: 1~6mm², wire stripping length: 10mm.

  1. Setarea parametrilor

Setting Current: Should be adjusted to 1.05~1.1 times the motor’s rated current to ensure protection sensitivity and avoid false tripping.

When the ambient temperature deviates significantly from 25℃, adjust the setting current according to the temperature compensation characteristic table.

  1. Operating Restrictions

Do not operate beyond the rated voltage or frequency.

The operating frequency shall not exceed 30 times/hour; frequent operation will shorten the service life.

It is strictly prohibited to disassemble or replace parts with live electricity; the power supply must be cut off first and confirmed to be de-energized.

  1. Referință de selecție

To select the appropriate NS2 series product for your motor:

  1. First determine the motor’s rated current.
  2. Choose a model whose setting current range includes the motor’s rated current.
  3. Motor power reference: NS2-25/4-6.3A is suitable for motors with a power of approximately 2.2kW (400V).
  4. In systems with high-order harmonics such as inverter power supply, it is recommended to select the specification according to 1.3~1.9 times the motor’s rated current.

Rezumat

Chint NS2-25/4-6.3A is a reliable-performance motor starter protection switch that integrates protection and control functions. It is particularly suitable for three-phase induction motors of around 2.2kW. Not only can it effectively protect motors from overload, phase failure, and short-circuit damage, but it also simplifies the design of control systems, making it an ideal choice in the field of industrial electrical control.