CHNT CJX2-4011 Contactor AC - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

contactor/

CHNT CJX2-4011 Contactor AC

CJX2-4011 is a 3-pole AC contactor from CHNT’s classic CJX2 series, with a 40A rated current and equipped with 1 NU + 1 Contacte auxiliare NC. It is suitable for AC-3 duty (de ex., three-phase motors) and widely used in industrial motor control, power distribution switching, and automation systems. It is a cost-effective choice from a ...

  • Detalii despre produs

CJX2-4011 is a 3-contactor AC poli from CHNT’s classic CJX2 series, with a 40A rated current and equipped with 1 NU + 1 Contacte auxiliare NC.

It is suitable for AC-3 duty (de ex., three-phase motors) and widely used in industrial motor control, power distribution switching, and automation systems. It is a cost-effective choice from a leading domestic brand.

  1. Model & Part Number Explanation
Model PartDescriere
CJX2Cod de serie (CJ = AC contactor, X2 = 2nd generation)
40Rated operational current of main poles: 40O (AC‑3, 380V)
11Contacte auxiliare: 1 NU (Deschis normal) + 1 NC (În mod normal închis)
Common coil voltagesAC24V / AC36V / AC110V / AC220V / AC380V (select as required)
  1. Core Technical Specifications
ArticolCaietul de sarciniNote
Marca & ModelCHNT CJX2-4011Compatible with Schneider LC1-D40 series
Poles3P (3 main poles)For three‑phase AC loads
Curent nominal (Ie)40O (AC‑3, 380V)Suitable for 18.5kW three‑phase motor
Rated operational voltage (Ue)Max. AC690VNormal use: AC380V/400V
Control coil voltageMulti‑range optional (AC24/36/110/220/380V)Must match control circuit voltage
Capacitate de rupereAC‑3: 40O; AC‑1: 110OMeets general industrial load switching
Contacte auxiliare1 NU + 1 NCFor status feedback and interlocking
Mounting35mm șină DIN + fixare cu șuruburiFits standard electrical cabinets
Wiring capacityMain: 4~10mm² Cu; Bobina: 1.5~2.5mm²
Durata de viata mecanica≥ 10 milioane de operațiuniReliable for frequent use
Durata de viata electrica≥ 1 milioane de operațiuni (AC‑3)Silver alloy contacts for durability
Operating temp-5℃ ~ +40℃For standard industrial environments
Protection degreeIP20Previne contactul degetelor cu piesele sub tensiune
  1. Caracteristici & Avantaje
  2. High-reliability contact system

Silver alloy contacts offer good conductivity, anti-welding, and arc resistance

32-sheet silicon steel core for stable, low-noise operation (≤55dB)

Red copper coil + flame-retardant housing for high temperature resistance

  1. Dual mounting flexibility

Standard 35mm DIN rail for quick installation

Also supports screw mounting for panel installation

  1. Energy saving

Low power consumption for long-term operation

Stable coil pull-in, reduced control circuit energy use

  1. Strong compatibility

Directly matches CHNT NR2 series thermal overload relays

Dimensions compatible with Schneider LC1-D40 series for direct replacement

  1. Instalare & Wiring Guide

4.1 Cerințe de instalare

DIN rail: Clip onto 35mm standard rail and ensure full locking

Screw mounting: Use M4 screws on a flat surface with ≥10mm clearance for heat dissipation

Prefer vertical installation; avoid horizontal mounting

4.2 Specificații de cablare

Tip terminalMarkingDescriereCautions
Main polesL1, L2, L3 (line); T1, T2, T3 (încărca)Connect three‑phase power / motorDisconnect power before wiring; torque 0.8~1.2N·m
BobinaA1, A2Connect to control circuit (pushbutton, PLC)Coil voltage must match; do not reverse polarity
AuxiliaryNU (13‑14), NC (21‑22)Feedback / interlock circuitDistinguish NO/NC correctly

4.3 Key Wiring Notes

Do NOT mix main pole and coil terminals

Securely crimp wires to avoid overheating

When used with a thermal relay, connect it after T1/T2/T3

  1. Aplicații tipice

Three-phase motor control: 7.5kW~18.5kW pumps, fani, transportoare

Distribuția de energie industrială: cabinet switching, capacitor bank control

Automated production lines: PLC-controlled start/stop and interlock

Building systems: HVAC, lifturi, fire pumps

Machine tools: strunguri, mașini de frezat, drilling machines

  1. Replacement Models & Compatibilitate

6.1 CHNT Upgraded Replacements

OriginalReplacementDiferența cheieApplication
CJX2-4011NXC-4011Kunlun series, upgraded contacts, smaller, lower powerNew panels, system upgrades
CJX2-4011CJX2-40011 NC onlyFault feedback only
CJX2-4011CJX2-40222 NU + 2 NCComplex interlocking

6.2 Cross-Brand Equivalents

MarcaEquivalent ModelMatching Specs
SchneiderLC1-D4011M5C40O, 3P, 1NU+1NC, AC220V coil
Siemens3TF4722-0XM040O, 3P, 2NU+2NC
ABBA40-30-1140O, 3P, 1NU+1NC
DeliciosCJX2-4011Directly interchangeable
  1. Purchasing & Sfaturi de utilizare
  2. Authenticity

Buy via official channels to avoid counterfeits

Verify model, tensiunea bobinei, and poles

  1. Accessories

Must use with NR2 thermal relay for motor overload protection

Surge suppressor (SR2 series) recommended for frequent switching

  1. Selection Rules

AC-3 for motors; AC-1 for resistive loads

Coil voltage must match control power

Higher protection grade for dusty/humid environments

  1. Întreţinere

Check terminal tightness every 6–12 months

Clean contacts and replace if worn

Energize briefly before long-term storage

> Nota: CJX2-4011 is a general-purpose contactor with high cost-performance, stable supply, and easy replacement. Widely used in machinery, chimic, building materials, light industry.

Complete CHNT AC Contactor Series-Models & Order Codes

Core Overview

CHNT AC contactors cover 5 main series:

CJX2 (classic), NXC (Kunlun upgrade), NC1 (industrial IEC), NC2 (curent mare), NC8 (high voltage heavy duty).

Models are coded by current + contacte auxiliare + tensiunea bobinei.

Order codes start with 710010xxxx and cover 6A ~ 1250A.

  1. CJX2 Series (Classic, being phased out)

Application: Small-medium motors, 35mm șină DIN, compatible with Schneider LC1-D.

ModelKey SpecsTypical Order Code (AC220V)Motor
CJX2-06106O, 1NU71001020006102202.2kW
CJX2-09109O, 1NU71001020009102204kW
CJX2-121012O, 1NU71001020012102205.5kW
CJX2-181018O, 1NU71001020018102207.5kW
CJX2-251025O, 1NU710010200251022011kW
CJX2-321032O, 1NU710010200321022015kW
CJX2-401140O, 1NU+1NC71001020040322018.5kW
CJX2-501150O, 1NU+1NC710010200501122022kW
CJX2-651165O, 1NU+1NC710010200651122030kW
CJX2-951195O, 1NU+1NC710010200951122045kW

> Nota: 01=1NC, 10=1NO, 11=1NO+1NC. Coil voltages: AC24/36/110/220/380V. Last 3 digits = voltage code.

  1. NXC Series (Kunlun Upgrade, Mainstream)

Application: CJX2 replacement, smaller, lower power, longer life.

ModelKey SpecsTypical Order Code (AC220V)Application
NXC-066O, 1NU710010100000498Motor mic, iluminat
NXC-099O, 1NU710010100000499Pumps, fani
NXC-1212O, 1NU710010100000500Small machines, A/C
NXC-1818O, 1NU7100101000005017.5kW motor
NXC-2525O, 1NU71001010000050211kW motor
NXC-3232O, 1NU71001010000050315kW motor
NXC-4040O, 1NU+1NC71001010000050418.5kW motor
NXC-5050O, 1NU+1NC71001010000050522kW motor
NXC-6565O, 1NU+1NC71001010000050630kW motor
NXC-8080O, 2NU+2NC71001010000050745kW motor
NXC-100100O, 2NU+2NC71001010000050855kW motor
NXCQ-4040O, mechanical emergency710010100002345Fire pump

> Nota: Z = DC coil (de ex., NXC-12Z DC24V); M = mechanical latching.

  1. NC1 Series (Industrial IEC Standard)

Application: International standard, high reliability, frequent operation.

ModelKey SpecsTypical Order Code (AC230V)Coil Type
NC1-09109O, 1NU7100161000910230AC
NC1-120112O, 1NC7100161001201230AC
NC1-251125O, 1NU+1NC7100161002511230AC
NC1-401140O, 1NU+1NC71001610804011200AC
NC1-651165O, 1NU+1NC71001610806511200AC
NC1-951195O, 1NU+1NC71001610809511200AC
NC1-1210Z12O, 1NU710016121210024DC24V
NC1-2501Z25O, 1NC7100161212501020DC24V

> Nota: NC1-N = reversing contactor. Z = DC coil.

  1. Seria NC2 (High Current Industrial)

Application: Heavy motors & main circuits up to 800A.

ModelKey SpecsTypical Order Code (AC220V)Application
NC2-150150O, 3P7100162001501220Main switch, large fan
NC2-225225O, 3P7100162002251220Air compressor
NC2-400400O, 3P/4P7100162004001220Data center
NC2-630630O, 3P/4P7100162006301220Large equipment
NC2-800800O, 3P/4P7100162008001220Main incomer

> Nota: 3P/4P available. Shunt trip, undervoltage release optional.

  1. NC8 Series (High Voltage Heavy Duty)

Application: Up to 1140V, 2650A for metallurgy, minerit, marine.

ModelKey SpecsTypical Order Code (AC220V)Application
NC8-12M1012O, 1NU71001680001210200High-voltage auxiliary
NC8-25M1125O, 1NU+1NC71001680002511200HV motor control
NC8-40M2240O, 2NU+2NC71001680004022200HV cabinet
NC8-100M22100O, 2NU+2NC71001680010022200Large HV motor
NC8-500M22500O, 2NU+2NC71001680050022200Mining, marine

> Nota: M = mechanical latching. 4P for 3P+N systems. DC coil available.

  1. General Selection & Order Code Rules

6.1 Model Coding

PositionSensExemplu (CJX2-4011 AC220V)
PrefixSerieCJX2, NXC, NC1
MiddleCurent nominal (AC‑3, 380V)40 = 40A
Suffix 1Contacte auxiliare11 = 1NO+1NC
Suffix 2Poles/function/4 = 4P; /Z = DC; /M = latching

6.2 Order Code Format

Standard: 710010xxxxxxx

Exemplu:

CJX2-4011 AC220V → 710010200403220

NXC-12 DC24V → 710010100000500Z

6.3 Puncte cheie de selecție

  1. Load: AC-3 for motors; AC-1 for resistive loads
  2. Coil voltage must match control power
  3. Contacte auxiliare: 10, 01, 11, 22
  4. Poles: 3P pentru trifazat; 4P for 3P+N
  5. Series Comparison & Recommendation
SerieActualKey StrengthApplication
CJX26A~95AMature, low cost, compatibilRetrofit, general use
NXC6A~100ASmall, low power, long lifeNew projects, automation
NC19A~95AIEC standard, high reliabilityExport, frequent duty
NC2150A~800AHigh current, heavy dutyIndustrie, data center
NC812A~2650AHV, extreme environmentMetallurgy, minerit, marine