CIUPERCĂ 750330 Releu de siguranță

Model complet: PNOZ s7 C 24VDC 4 n/o 1 n/c Pilz PNOZsigma Series Safety Relay Basic Specifications Order No.: 750330 Livra: 24 V DC Safety Contacts: 4 deschis în mod normal (n/o) Contact auxiliar: 1 în mod normal închis (n/c) Lăţime: 22.5 mm Function: For safety emergency stop, monitorizarea portilor de siguranta, two-hand control and other safety circuit evaluation Series: ...

  • Detalii despre produs

Model complet: PNOZ s7 C 24VDC 4 n/o 1 n/c

Pilz PNOZsigma Series Releu de siguranță

Specificații de bază

Comanda nr.: 750330

Livra: 24 În DC

Contacte de siguranță: 4 deschis în mod normal (n/o)

Contact auxiliar: 1 în mod normal închis (n/c)

Lăţime: 22.5 mm

Funcţie: For safety emergency stop, monitorizarea portilor de siguranta, two-hand control and other safety circuit evaluation

Serie: PNOZ s7 C (C = with cascade interface, for connecting extension modules)

Certificari: CE, UL, TÜV; Safety Level PL e/SIL 3 (Compliant with ISO 13849-1/IEC 62061)

Aplicații tipice

Emergency stop button circuit monitoring

Safety gate switches, întrerupătoare de limită de siguranță

Small automation machines, masini-unelte, packaging machinery safety control

Can be cascaded with PNOZsigma extension modules (s0, s1, s2, s4, s5, s6, s7, s8, s9) pentru extinderea contactului

Confusing Model Comparison

750107: PNOZ s7 (without C, fără funcție în cascadă)

750330: PNOZ s7 C (cascade-capable version)

Note de cablare

  1. S11/S12: Safety Input Channel 1
  2. S21/S22: Safety Input Channel 2 (Monitorizare pe două canale)
  3. 13/14, 23/24, 33/34, 43/44: Four safety normally open outputs
  4. 51/52: Auxiliary normally closed feedback contact
  5. UB/0V: 24Alimentare V DC

Referință de înlocuire

Înlocuire din aceeași serie: Original product is preferred for the same specification; domestic safety relays can be used for functional replacement (PL level, contact configuration and wiring logic must be verified)

Upgrade: If more contacts are required, cascade with PNOZ s extension modules

Informații suplimentare

Clasa de protectie: IP20 (Montare pe șină DIN, numai pentru instalarea dulapului)

Montare: DIN 35mm rail

Temperatura de operare: -10 ℃ ~ +55 ℃

CIUPERCĂ 750330 (PNOZ s7 C) Instrucțiuni de cablare + Lista de verificare pentru depanare

Important Precaution: PNOZ s7 C is a contact extension module. It cannot be used as a standalone master module. It must be used with PNOZsigma master safety relays (s1/s2/s4/s5/s6 etc.); C = cascade connector, connected to master module via U-link. It is NOT an independent evaluation unit.

  1. Definiția terminalului

A1: 24VDC+

A2: 24VDC-

Ieșiri de siguranță (Force-guided normally open, for safety circuits)

13-14, 23-24, 33-34, 43-44 (4 sets n/o)

Contact auxiliar (Not allowed for safety cut-off circuits, only for PLC feedback/indicator lamps)

51-52 (1 set n/c)

Top side: Cascade slot + Terminator plug

  1. Two Wiring Schemes

Sistem 1: Cascade with PNOZsigma Master Module (Recomandat, with pulse detection)

  1. Mount master module and s7 C side by side on DIN rail, remove terminator plugs on both modules
  2. Insert PNOZsigma U-link connector; internal safety signals are transmitted from master module to s7C
  3. Master module is powered at A1/A2; s7C A1/A2 also requires separate 24V DC supply
  4. Route outputs 13-14/23-24/33-34/43-44 into contactor coil circuits; a 6A fuse is recommended to prevent contact welding
  5. 51-52 is wired to PLC digital input for status feedback

Cascade Rule: The terminator plug must be fitted on the LAST module of the cascade chain! Fault will be triggered if missing.

Sistem 2: Hardwired extension for non-sigma series (PNOZ X etc., no U-link)

The safety output contact of the master relay is wired into the s7 C supply loop (master safety contact acts as enable for s7C power supply)

Master contact closed → s7C energized, all safety outputs closed

Master contact open → s7C de-energized, all safety outputs open

⚠️ No internal short-circuit pulse diagnosis in this mode. Safety architecture is downgraded, only for low-risk applications.

  1. Reguli de cablare de siguranță
  2. Max. load for safety outputs: ≤6A, 240VAC; fuses are mandatory to avoid contact welding
  3. 51-52 auxiliary contact must not be used for safety cut-off, only for status signals
  4. Cablu: Copper wire with ferrule for cabinet wiring, borna cu arc; IP20, no exposed wiring
  5. Emergency stop/safety gate logic is fully configured on the PNOZsigma master module (mode selector, dual-channel detection, resetare automată/manuală). s7C only follows the output state
  6. Check U-link connection regularly for vibration-prone applications (masini-unelte, transportoare)
  7. Indicator LED Definiție (PNOZ s7C itself)

PUTERE: 24V supply present

OUT: Safety outputs closed (master module permits output)

VINEA: Diagnostic error/fault lockout

IN1, IN2 indicators are located on the master module. The s7C extension module has no input indicators.

  1. Lista de verificare pentru depanare (în succesiune)

Vina 1: FAULT LED ON continuously, nicio iesire (cel mai frecvent)

Cauza 1: Terminator plug missing or not installed on the last module

Remediu: Opriți, fit terminator plug on the last module’s cascade slot, power on and reset

Cauza 2: U-link loose or not fully clipped

Remediu: Opriți, re-seat U-link and confirm locking

Cauza 3: No supply/reversed polarity/excessive voltage drop on A1/A2

Remediu: Measure A1-A2 voltage with multimeter, confirm stable 24VDC; check spring terminal loose connections

Cauza 4: Master module FAULT, wrong mode setting, short circuit on master input channels

Remediu: Troubleshoot master module first; s7C will only work normally once master is recovered

Vina 2: POWER LED ON, OUT LED OFF, FAULT LED OFF

Cauza 1: Master safety relay is in safe-off state (E-stop pressed, safety gate open)

Remediu: Reset E-stop/close safety gate, confirm master OUT LED lights up

Cauza 2: Master module set to manual reset and reset button not pressed

Cauza 3: Wrong cascade order; master module is not the first unit in chain

Cauza 4 (hardwired mode): Master safety contact damaged/open circuit

Vina 3: Intermittent FAULT trigger, output flickering

Cauza 1: U-link loose due to cabinet vibration (masini-unelte, linii de transport)

Cauza 2: High ripple/insufficient capacity/frequent dip on 24V power supply

Cauza 3: Short circuit on output circuit, fuse blown and safety lockout activated

Cauza 4: Cross-wire/earth short circuit on master module input wiring (pulse detection triggers fault)

Vina 4: FAULT latched, cannot reset after power cycle

Cauza: Internal safety contact welding (overload/short circuit without fuse protection)

Remediu: Module cannot be repaired; înlocuiți direct. Add fuses on output circuits to prevent recurrence.

Vina 5: Master module normal, s7C output out of sync

Cauza: Poor U-link contact; or welded contact on intermediate contactor in hardwired configuration

  1. Standard Commissioning Procedure
  2. Opriți, mount on DIN rail, wire power supply, fit U-link and terminator plug
  3. Wire master module and set mode selector (adjust selector only when power OFF; changing under power will lock fault)
  4. Verify fuses on all safety output loops
  5. Porniți. Master IN1/IN2 OK, master OUT ON → s7C POWER + OUT ON
  6. Test de funcționare: Trigger E-stop/open gate → master OUT OFF, s7C OUT opens synchronously; reset and confirm synchronous closing
  7. Înregistra: Safety function verification must be performed after every wiring change or module replacement
  8. Quick Comparison: s7 (750107) vs s7 C (750330)

750107: PNOZ s7, extensie, no C, U-link cascade not supported

750330: PNOZ s7 C, extensie, C version, U-link cascade supported (modelul dvs)

Working Principle of PILZ 750330 (PNOZ s7 C)

Core summary: It has no input channels and no safety logic evaluation function. It is a follower-type extension module equipped with force-guided safety contacts. Safety judgement, dual-channel detection and short-circuit pulse diagnosis are all performed by the upstream PNOZsigma master module. The s7 C only synchronously follows the master safety command and feeds back its actual contact status to the master for verification.

Important: PL e/SIL3 safety rating is determined by the master module. s7 C alone cannot raise the safety level.

  1. Internal Hardware Structure

Intern: Two independent safety relays with mechanically linked force-guided contacts, 4 safety normally open outputs + 1 auxiliary normally closed feedback contact

Alimentare electrică: Independent 24VDC supply on A1/A2 (not powered by master module)

Top U-link port: Dual-channel drive signals + feedback return line, safety link; not ordinary communication bus

Terminator plug: Closing component for the end of cascade chain, used by master module to confirm chain integrity; fault is triggered if removed

  1. Standard Cascade Mode (U-link connection, recommended dual-channel safety architecture)
  2. Master module (s1/s2/s4/s5/s6 etc.) collects E-stop and safety gate signals, performs dual-channel comparison, cross-line short-circuit pulse detection and reset logic
  3. When safety conditions are satisfied, master sends synchronized dual-channel drive signals to s7 C via U-link
  4. s7 C receives valid drive signals → internal two safety relays pull in simultaneously, 13-14, 23-24, 33-34, 43-44 four safety contacts close
  5. Critical safety closed-loop: The actual contact state of s7 C is sent back to master module via cascade lines

Master continuously compares: issued command vs real feedback contact status

Matched: Funcționare normală

Mismatched (sudura prin contact, failure to act, ruperea firului, loose U-link): Master cuts drive immediately, whole safety chain locks FAULT, safety contacts force open

  1. Once safety trip condition occurs (E-stop pressed, safety gate opened): Master stops drive signal → s7C relays de-energize, all safety contacts open; status feedback is sent back to master for verification

This bidirectional verification is the core of force-guided contact + feedback monitoring, preventing dangerous failure mode where contacts remain conductive after open command due to welding.

  1. Hardwired Mode (without U-link, downgraded single-channel)

Master safety output contact is wired into s7C supply enable loop:

Master contact closed → s7C energized, outputs closed

Master contact open → s7C de-energized, outputs open

⚠️ Defect: No dual-channel feedback. Master cannot diagnose internal faults of s7C. Safety architecture no longer meets PL e, only for low-risk applications.

  1. LED Logic

PUTERE: A1/A2 24V supply OK

OUT: Valid drive signal received from master, safety contacts closed

VINEA: Master detects chain anomaly (loose U-link, missing terminator, inconsistent feedback, broken cascade line), safety lockout activated

  1. Diagnosis Principle (Why missing terminator triggers FAULT)

The whole cascade chain forms a serial closed diagnostic loop: Master → s7C1 → s7C2 → … → terminator plug on last module.

Master continuously sends diagnostic pulses scanning the whole chain. The terminator acts as an end termination resistor to close the pulse circuit.

Plug removed → pulse circuit open → master detects broken chain and locks FAULT to prevent uncontrolled extension module behaviour.

  1. Function Division: Master vs s7 C

Modul Master:

Connect E-stop/safety gate inputs

Dual-channel detection, cross-wire short-circuit detection, reset logic

Send drive commands + receive feedback and fault judgement from all extension modules

PNOZ s7 C (750330):

No input terminals, cannot connect E-stop

Acţiune: Pull in/open safety contacts synchronously

Feed back real contact status continuously to master for verification

Only increases available safety contacts, no safety logic evaluation

  1. Core Safety Design

Internal relays adopt mechanical force-guided structure: If one relay contact welds closed, the mechanical coupling ensures the other contact opens reliably. This anomaly is fed back to master and triggers fault lockout, avoiding dangerous “command open but contact conductive” failure.

Pilz PNOZ Safety Relay Order List

Nota: PNOZsigma (750xxx/751xxx) is current mainstream series; PNOZ X (774xxx /777xxx /787xxx) is legacy classic series; PNOZmulti2 is programmable safety controller. s7 C (750330) is sigma contact extension module and cannot be used standalone.

Abreviere: n/o=normally open, n/c=normally closed, n/o t=delayed-off normally open, SC=semi-conductor output

  1. PNOZsigma Series (24VDC, preferat, PL e/SIL3)

Standalone Master Modules (can work alone for E-stop/safety gate)

Comanda nr.Model completContact SpecLăţimeObservații
750101PNOZ s1 24VDC 2n/o2NU12.5mmSingle channel, de bază
750102PNOZ s2 24VDC 3n/o 1n/c3NU+1NC17.5mmSingle channel
750103PNOZ s3 24VDC 2n/o2NU17.5mmDual-channel short-circuit detection
751103PNOZ s3 C 24VDC 2n/o2NU17.5mmCascade C version
750104PNOZ s4 24VDC 3n/o 1n/c3NU+1NC22.5mmCanal dublu, utilizat pe scară largă
750105PNOZ s5 24VDC 2n/o 2n/o t2NO+2 delayed NO22.5mmDelay-off type
750106PNOZ s6 24VDC 3n/o 1n/c3NU+1NC22.5mmTwo-hand control dedicated
750107PNOZ s7 24VDC 4n/o 1n/c4NU+1NC22.5mmExtensie, no U-link cascade
750330PNOZ s7 C 24VDC 4n/o 1n/c4NU+1NC22.5mmCascade C version, U-link compatible (modelul dvs)
750108PNOZ s8 24VDC 2n/o2NU12.5mmSmall contact extension
750109PNOZ s9 24VDC 3n/o3NU17.5mmContact extension
750110PNOZ s10 24VDC 2n/o2NU12.5mmDual-channel light curtain
750111PNOZ s11 24VDC 4n/o4NU22.5mmCanal dublu
750124PNOZ s4.1 24VDC3NU+1NC22.5mmSpecial reset mode
750126PNOZ s6.1 24VDC3NU+1NC22.5mmImproved two-hand control
750150PNOZ s20 24VDCSemi-conductor output12.5mmPure semiconductor
750151PNOZ s22 24VDCSemi-conductor output17.5mmLight curtain dedicated
750130PNOZ s30 24VDC2NO+2 delayed NO22.5mmÎntârziere lungă
750152PNOZ s50 24VDCSemi-conductor22.5mmSemi-conductor safety output

Sigma Accessories

Comanda nr.Descriere
750008PNOZsigma U-link Cascade Connector
750009Terminator Plug (mandatory at end of chain)
  1. PNOZ X Legacy Series (AC/DC universal, for replacement of existing projects)

Basic E-stop/Safety Gate Models

Comanda nr.ModelContacteLivra
777303PNOZ X2P2NU24VAC/DC
787059PNOZ X7P C2NU24VAC/DC
774053PNOZ X72NU110VAC
774055PNOZ X72NU120VAC
774057PNOZ X72NU240VAC
787100PNOZ X1P C3NU+1NC24VDC
787310PNOZ X3P C3NU+1NC24VAC/DC
774729PNOZ X63NU24VAC/DC
774080PNOZ 117NU+1NC24VAC/DC
774006PNOZ 106NU+4NC230-240VAC

Delay-off XV Series

Comanda nr.ModelContacteInterval de întârziere
777510PNOZ XV3P 303NO+2 delayed NO0.1~30s
774610PNOZ XV3.1 303NO+1NC+2 delayed NO0.1~30s
774618PNOZ XV3.1 3003NO+1NC+2 delayed NO0.3~300s

Two-hand Control P2HZ Series

Comanda nr.ModelContacte
777340P2HZ X1P3NO+1NC+2SC
774350P2HZ X32NU+1NC
774360P1HZ X12NU

Contact Extension PZE Series (for PNOZ X master)

Comanda nr.ModelContacte
774580PZE X44NU
777580PZE X4P4NU
774590PZE X55NU
777600PZE 9P7NU+2NC
  1. PNOZmulti 2 Programmable Safety Controllers (Large machines, multi safety functions)
Comanda nr.ModelDescriere
772100PNOZ m B0Unitate de bază, extensibil
772104PNOZ m B0.1B0 upgraded version
772105PNOZ m C0Compact, neextensibil
772138PNOZ m ES ETHEthernet communication module
  1. Ghid de selecție rapidă
  2. 750xxx = PNOZsigma new series; 750xxx without C = standalone/hardwired extension; 751xxx /7503xx with C = U-link cascade supported
  3. 774/777/787xxx = PNOZ X legacy series, for spare replacement only, nu este recomandat pentru proiecte noi
  4. 772xxx = PNOZmulti2 programmable safety controller (not simple safety relay)
  5. s7 (750107) and s7C (750330) are both extension modules, cannot connect E-stop independently, must pair with sigma master
  6. Confusing Model Reference

750107: PNOZ s7, extensie, no C, U-link cascade not supported

750330: PNOZ s7 C, extensie, C version, U-link cascade supported