Schneider Electric NSX250N-3P-160A - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

Schneider Electric NSX250N-3P-160A - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

întrerupător de circuit/

Schneider Electric NSX250N-3P-160A

This is a Schneider Electric ComPacT NSX series molded case circuit breaker (MCCB) for power distribution protection. New standard order number: C25N3TM160 Obsolete old order number: LV431832 Compliant with IEC 60947‑2 and GB/T 14048.2 standardele. Basic Rated Core Parameters Item Value Type Low‑voltage MCCB for power distribution protection Frame rating 250A Poles 3P (3 stâlpi, ...

  • Detalii despre produs

This is a Schneider Electric ComPacT NSX series întrerupător cu carcasă turnată (MCCB) for power distribution protection.

New standard order number: C25N3TM160

Obsolete old order number: LV431832

Compliant with IEC 60947‑2 and GB/T 14048.2 standardele.

  1. Basic Rated Core Parameters
ArticolValoare
TipLow‑voltage MCCB for power distribution protection
Frame rating250O
Polonii3P (3 stâlpi, all protected)
Rated current In160O (continuous at 40℃)
Rated operational voltage Ue690V AC 50/60Hz, suitable for 380V/400V/415V systems
Rated insulation voltage Ui800V și
Rated impulse withstand voltage Uimp8kV
Frecvenţă50/60Hz
Utilization categoryTip A (no short‑time delay, general distribution)
Funcția de izolareCertified isolating function per IEC 60947‑2
  1. Short‑Circuit Breaking Capacity
Tensiunea sistemuluiRated ultimate shortircuit breaking capacity IcuRated service shortircuit breaking capacity Ics
415V și50cel50cel (100% Icu, reusable after breaking)
500V și36cel36cel
690V și10cel10cel

Rated short‑time withstand current Icw (1s): 12kA at 415V AC

  1. TMD Thermal‑Magnetic Release Characteristics

Standard TMD thermal‑magnetic release, LI protection (long‑time overload + instantaneous short‑circuit).

  1. Long‑time overload thermal protection

Ir setting range: 0.7–1×In (112A–160A)

Characteristic: 120–400s at 1.5×Ir; ≤15s at 6×Ir (standard inverse time)

  1. Short‑circuit instantaneous magnetic protection

Instantaneous current Ii: fixed at 1250A

Timp de funcționare: ≤20ms

  1. Mechanical & Parametrii de instalare
ArticolValoare
Dimensiuni (W×H×D)105mm × 161mm × 86mm
Standard mounting centersVertical 125mm × Horizontal 35mm
MontareFixed, front connected; horizontal/vertical, no derating
Capacitatea cablajuluiUp to 70mm² copper cable / busbar
Mechanical endurance20,000 operațiuni
Electrical endurance10,000 operations at 440V AC, În
Ingress protectionIP40 (body), IP54 (panel‑mounted)
Impact resistanceIK07
Net weightAproximativ. 2.4kg
  1. Environmental & Compliance Parameters

Temperatura mediului ambiant: -25℃ ~ +70℃; no derating below 40℃

Altitudine: 0–2000m without derating

Pollution degree: 3

Overvoltage category: II

Certificari: CCC, CE, EAC, Marine, etc.

Accessory slots: 5 standard slots for auxiliary, alarm, shunt, undervoltage release, etc.

  1. Expansiune & Compatibilitate

Can be fitted with Vigi earth‑leakage modules

Compatible with motor operators for remote control

Can add interlock, position indicator, padlock devices

Top/bottom feed both allowed without performance derating

Înlocuire & Note de selecție

  1. Old type LV431832 is discontinued; use C25N3TM160 instead.
  2. For electronic release (adjustable short delay / earth fault), upgrade to NSX250N with MicroLogic (2.2/5.0).
  3. Breaking ratings: H (70cel), S (100cel), based on short‑circuit calculation.
  4. Competitors: ABB Tmax T2, Siemens 3VT250, suitable for cross‑brand replacement.

NSX250N‑3P‑160A Direct Replacement Solutions

Core Matching Rules (100% match required)

Frame rating: 250O (do NOT downgrade to 160A frame)

Polonii: 3P

Curent nominal: 160O

Capacitate de rupere: ≥50kA at 415V AC

Release type: thermal‑magnetic (LI characteristic)

Montare: fixed front connection, matching panel holes

  1. Recommended Replacements

Scenariu 1: Import Brand Direct Replacement

ABB Tmax XT3N250 TMD160/1600 FF 3P

Comanda nr.: 1SDA068266R1

Match: 100%

Frame 250A, 3P, 160O, TMG thermal‑magnetic

Icu=50kA, Ics=50kA at 415V AC

Identical dimensions and mounting holes

Full accessory compatibility

Aplicație: foreign‑funded plants, export equipment, on‑site repair

Siemens 3VC250N TMA160 3P

Comanda nr.: 3VC2316‑2DA33‑0AA0

Match: 98%

Frame 250A, 3P, 160O, TMA thermal‑magnetic

50kA at 415V AC

Highly compatible dimensions

Aplicație: Siemens low‑voltage systems

Scenariu 2: Domestic High‑Cost‑Performance Replacement

Changshu Switch CM3‑250H/3300 160A

Match: 99%

Frame 250A, 3P, 160O, distribution type thermal‑magnetic

Icu=50kA at 415V AC

Compliant with IEC 60947‑2 / GB 14048.2

Aplicație: industrial, building distribution, domestic projects

Chint NM8‑250N/3P 160A

Match: 95%

Frame 250A, 3P, 160O, thermal‑magnetic

50kA at 415V AC

Aplicație: civil construction, general distribution

  1. Dimensiuni & Parameters Comparison
ModelDimensiuni (W×H×D)Mounting CentersIcu (415V)ReleaseFrame
NSX250N‑3P‑160A105×161×86mm125mm×35mm50celTMD250O
ABB XT3N250 3P 160A105×161×86mm125mm×35mm50celTMG250O
Siemens 3VC250N 3P 160A105×160×85mm125mm×35mm50celTMA250O
CM3‑250H 3P 160A108×162×86mm125mm×35mm50celThermal‑magnetic250O

> Nota: ABB XT3N250 matches dimensions and holes 100% – best direct replacement.

  1. Safety Rules for Replacement
  2. No frame downgrade: Do NOT use 160A frame breakers (de ex., ABB T2N, NSX160).
  3. Breaking capacity ≥50kA: Do NOT use 36kA / 25kA models.
  4. Release matching: Use distribution‑type thermal‑magnetic only.
  5. Accessory compatibility: Match auxiliary, shunt, subtensiune, earth‑leakage modules.
  6. Final Selection Guide

Înlocuire directă, import, no cabinet modification: ABB XT3N250 TMD160/1600 FF 3P

New project, domestic approval, cost‑effective: Changshu CM3‑250H/3300 160A

Siemens system replacement: Siemens 3VC250N TMA160 3P

Prev:

Următorul:

Lasă un răspuns

Lăsaţi un mesaj