Specificatii tehnice & Application Guide This is a 2‑pole, Tip C, 25A miniature circuit breaker (MCB) din seria Acti9 de la Schneider Electric, with order code A9F18225 and rated breaking capacity 6kA. It provides overload and short‑circuit protection for lighting, socket, and small motor circuits in AC distribution systems. Features include 3‑stage current limiting, quick make mechanism, ...

  • Detalii despre produs

Specificatii tehnice & Application Guide

This is a 2‑pole, Tip C, 25O întrerupător miniatural (MCB) din seria Acti9 de la Schneider Electric, with order code A9F18225 and rated breaking capacity 6kA.

It provides overload and short‑circuit protection for lighting, socket, and small motor circuits in AC distribution systems.

Features include 3‑stage current limiting, quick make mechanism, and protection degree IP40 (front) / IP20 (terminals).

It is compatible with iC65 series accessories for functional expansion.

  1. Model Breakdown
CodeSensDescriere
SCHNEIDERMarcaSchneider Electric (Franţa), global electrical equipment manufacturer
iC65NSerieActi9 iC65 MCB, N‑type breaking capacity (6cel)
2PNumber of poles2‑pole, breaks phase and neutral simultaneously, for 230V/400V systems
CTripping curveTip C, instantaneous tripping at 5~10×In (5In~10In)
25OCurent nominal25 amperes continuous at 30°C ambient
A9F18225Full order codeOfficial unique identifier
  1. Specificații de bază
ArticolCaietul de sarciniNote
Basic
TipÎntrerupător în miniatură (MCB)Conform IEC 60898-1 / GB 10963.1
Tripping typeThermal‑magneticOverload (thermal) + short‑circuit (magnetic) protecţie
Capacitate de rupere6celMax breaking current at rated voltage
Rated operational voltageAC 230V/400VFor 2‑pole version
Tensiunea nominală de izolație500VMax withstand voltage of insulation
Rated impulse withstand voltage6kVSurge voltage immunity
Rated frequency50/60HzGlobal grid compatible
Tripping characteristics
Protectie la suprasarcina1.13În (no trip in 1h), 1.45În (trip within 1h)Meets IEC requirements
Short‑circuit protectionInstantaneous at 5In~10InTip C, suitable for lighting, sarcini rezistive, small motors
Physical & environmental
Dimensiuni (W×H×D)18mm×86mm×62mmStandard modular, 2P = 2 modules (18mm/pole)
Protection degreeIP40 (front), IP20 (terminals)Solid object and moisture protection
Temperatura de functionare-35°C ~ +70°CSuitable for harsh industrial environments
Mounting35mm șină DINStandard panel mounting
CertificariCCC, CE, RoHSMeets Chinese and international safety & environmental standards
  1. Caracteristici
  2. Protection performance

3‑stage current limiting: Quickly limits peak current during short circuit, reduces thermal stress, protects equipment and cables.

Selective protection: Coordinates with upstream breakers for selective tripping, limits fault area.

Fault indication: Red window shows tripped status for quick diagnosis.

  1. Structural advantages

Dual‑lock clip: Secures firmly on DIN rail, prevents vibration loosening.

Quick make mechanism: Improves closing speed, reduces arcing, extends life.

Design modular: Accepts auxiliary contacts, alarm contacts, excursie cu șunt, declanșare la subtensiune, etc.

  1. Safety design

Isolation function: Safe isolation distance in OFF position, meets electrical safety rules.

Anti‑misoperation: Handle design prevents accidental closing.

Flame‑retardant housing: V0 grade material improves cabinet safety.

  1. Instalare & Întreţinere

Installation Rules

  1. Mount vertically (±15°) for proper tripping.
  2. Cablaj: Copper 1.5~35mm², Aluminium 2.5~35mm², torque 1.2~4N·m (depends on cross‑section).
  3. Environment: Avoid damp, prăfuită, corrosive or high‑vibration locations.
  4. Spacing: Maintain clearance for heat dissipation; follow installation manual.

Maintenance Guide

ArticolIntervalCriterionSoluţie
Visual inspectionMonthlyNo damage, no overheating, tight connectionsClean, tighten loose terminals
Function testQuarterlyManual ON/OFF smooth, no stickingOperate 3–5 times, check mechanism
Trip testAnnuallyOverload & short‑circuit protection functionalTest with dedicated equipment or simulate overload
Accessory checkAnnuallyAuxiliary & alarm contacts workingCheck contact condition, înlocuiți piesele deteriorate

Depanare

  1. Deplasări frecvente: Check overload → short circuit → high ambient temperature → aging.
  2. Cannot close: Check short circuit → handle position → trip reset → loose wiring.
  3. Overheating: Check terminal torque → overload → ventilation.
  4. Upgrade & Replacement

5.1 Same‑series Upgrades

iC65H-2P-C25A (A9F28225): H‑type, 10cel, for higher short‑circuit current.

iC65L-2P-C25A (A9F38225): L‑type, 15cel, for heavy industrial use.

iC65N-2P-C25A‑Vigi (A9V58225): With residual current protection (RCCB), prevents electric shock.

5.2 Functional Accessories

AccessoryTypical ModelFuncţie
Contact auxiliarA9A269241NU+1NC, remote status indication
Shunt tripA9X16224Remote tripping, de ex., fire alarm
Undervoltage tripA9X16624Auto‑trip on low voltage
Alarm contactA9A27924Signal when breaker trips

5.3 Cross‑series Alternatives

SerieReplacementCompatibilitate
Easy9EA9AN 2P C25ASame dimensions, 6cel, economical
Acti9 CVSCVS100B 2P C25AMCCB, capacitate de rupere mai mare (10cel), main circuit use
Merlin GerinC65N 2P C25AFully compatible with iC65
  1. Applications
  2. Commercial buildings: Offices, magazine, hotels – lighting & socket circuits.
  3. Automatizare industrială: Control panels, small motors (≤5,5kW), VFD input protection.
  4. Rezidențial: Home distribution – air conditioners, kitchen appliances.
  5. Public facilities: Schools, hospitals, stadiums – electrical safety.
  6. Selecţie & Purchasing Tips
  7. Potrivirea încărcării: Type C for lighting, prize, small motors (≤5,5kW). Use Type B for pure resistive, Type D for large motors.
  8. Capacitate de rupere: Choose N (6cel), H (10cel), L (15cel) based on system short‑circuit current.
  9. Poles: 2P for 230V single‑phase where phase + neutral must be disconnected.
  10. Accessories: Add aux, shunt, undervoltage for smart systems.
  11. Authenticity: Buy from authorized Schneider distributors.
  12. Quick Fault Guide
SymptomPossible CauseSoluţie
Trips immediately after closingShort circuit / suprasarcinaLocate short, reduce load or upsize breaker
Trips after running a whileOverload / temperatură ridicatăReduce load, improve ventilation, check cable size
Handle cannot be pushed to ONNot reset / wiring faultPull to OFF first, then ON; check circuit
Terminal overheatingLoose connectionRetorque after power off, check terminals
No operationThermal‑magnetic unit failedReplace MCB, check coordination

SCHNEIDER iC65N-2P-C25A

Cross‑Brand Replacement Guide

Core Summary: The iC65N-2P-C25A (A9F18225) can be directly replaced by equivalent MCBs from major international and domestic brands.

Key matching requirements:

2P, Tip C, 25O, 6cel, 35mm DIN rail mounting.

  1. International Brand Direct Replacements

ABB

ReplacementOrder CodeBreakingCompatibilitate
S202-C252CDS252001R02546celBest match, same dimensions, direct swap
S202M-C252CDS262001R025410celHigher breaking capacity
S202L-C252CDS242701R02544.5celEconomy option

Siemens

ReplacementSerieBreakingCompatibilitate
5SL6225-75SL6celDirect replacement, IEC 60898-1
5SY6225-75SY6celEconomy range
5SN6225-7CN5SN6celClassic, reliable

Eaton

ReplacementSerieBreakingCompatibilitate
FAZ6-C25/2FAZ6celSame dimensions & mounting
PL9-C25/2PL96celHigh performance, fast limiting

Moeller

ReplacementSerieBreakingCompatibilitate
FAZ6-C25/2FAZ6celSame dimensions & mounting
PL9-C25/2PL96celHigh performance, fast limiting
  1. Chinese Domestic Brands
MarcaReplacementBreakingCompatibilitate
CHINTNXB-63-2P C256celCost‑effective, direct fit
DELIXICDM3-63C25/2P6celSame dimensions
LiangxinNDM1-63C25/2P6celHigh quality domestic
TENGENTGM1-63C25/2P6celBasic protection, economical
  1. Critical Parameter Matching
ArticolOriginal (iC65N-2P-C25A)Must MatchReglabilNote
Poles2P2PDisconnect phase + neutral
CurveTip C (5~10In)Tip CFor lighting & small motors
Actual25O25OContinuous rating
Breaking6cel≥6kACan be higher (10cel)Ensure safe short‑circuit interruption
Mounting35mm șină DIN35mm șină DINStandard panel mount
Lăţime18mm18mmH/D may varyFits standard spacing
VoltajAC 230V/400VAC 230V/400VUniversal AC system
  1. Replacement Notes & Best Practice

Before Replacement

System short‑circuit current ≤ breaking capacity of replacement.

35mm șină DIN, space, terminal size compatible.

Protection coordination with upstream/downstream devices.

Accessory mounting interface compatible.

Replacement has valid certifications (CCC, CE).

Procedure

  1. Power off and verify voltage absence.
  2. Remove wiring and old breaker.
  3. Clip replacement onto DIN rail.
  4. Torque terminals correctly.
  5. Test ON/OFF and tripping.
  6. Update labeling and drawings.

When NOT to replace

Original uses dedicated Schneider accessories (de ex., Vigi modules).

System short‑circuit current exceeds replacement rating.

Load inrush >10În (unsuitable for Type C).

Extreme environment outside replacement specs.

  1. Recommended Replacement Levels
NivelRecommended ModelsApplicationAdvantage
1stABB S202-C25Industry, comerţFull performance, global support
Siemens 5SL6225-7
2ndEaton FAZ6-C25/2Control panelsGood value, easy install
Moeller DIL M9-25 C/2
3rdCHINT NXB-63-2P C25Rezidențial, economyLow cost, fast local supply
DELIXI CDM3-63C25/2P
  1. Common Issues & Soluții
IssueCauzaSoluţie
Frequent tripping after replacementWrong curve / suprasarcinaConfirm Type C, check load, upsize if needed
Will not fitWrong rail / lăţimeUse 35mm DIN rail, 18mm width model
Wiring difficultIncompatible terminalsUse suitable lugs or select compatible model
Insufficient breaking capacityReplacement < system short鈥慶ircuit currentUse higher version (de ex., ABB S202M-C25, 10cel)

Cross‑brand replacement for SCHNEIDER iC65N-2P-C25A depends on parameter matching + mechanical compatibility + protection coordination.

Top international brands (ABB, Siemens) give identical performance.

Domestic brands (CHINT, DELIXI) offer cost savings.

Always verify specifications and follow electrical safety standards.