Tip de produs: 3-contactor AC poli, discontinued. Recommended replacement: 3RT6026-1AN20 (domestic 3RT6 series) Parametrii de bază: 22O / 400V at AC-3 duty, suitable for 11kW motors; coil AC230V 50/60Hz; auxiliary contacts 2NO + 2NC Positioning: Size 1, general-purpose industrial type, used for motor starting/stopping, equipment control and power distribution switching Full Model Interpretation (Including Complete Order Number) ...

  • Detalii despre produs

Tip de produs: 3-contactor AC poli, discontinued. Recommended replacement: 3RT6026-1AN20 (domestic 3RT6 series)

Parametrii de bază: 22O / 400V at AC-3 duty, suitable for 11kW motors; coil AC230V 50/60Hz; auxiliary contacts 2NO + 2NC

Poziționare: Size 1, general-purpose industrial type, used for motor starting/stopping, equipment control and power distribution switching

  1. Full Model Interpretation (Including Complete Order Number)

Complete order number: 3TF4322-0XM0. Segment meanings are as follows:

Segmentul de modelSensDetailed Description
3TFCod de serieSiemens AC contactor series (distinguished from 3TH auxiliary contactors and older 3TB series)
43Size / Evaluare curentăSize 1, rated current 22A at AC-3 400V, suitable for 3-phase motors up to 11kW
22Configurarea contactelor auxiliare2 Deschis normal (NU) + 2 În mod normal închis (NC), standard built-in auxiliary contacts, expandable
0XTip bobină0X = AC coil (1X = DC coil); 0XM indicates AC230V series
M0Tensiunea bobineiAC230V 50/60Hz. Full voltage codes: M=230V, F=115V, G=42V, Q=400V
StatusProduct LifecycleDiscontinued. Siemens official recommendation: upgrade to 3RT6 / 3RT5 series
  1. Core Technical Specifications (Authoritative Data)
Categoria parametrilorCaietul de sarciniObservații / Aplicație
Parametrii circuitului principal
Numărul de poli3-pol3-phase AC circuit, no neutral pole
Tensiune nominală de funcționareAC 690V (izolare); AC 400V (typical)Standard industrial voltage range
AC-3 Rated Current22OAt 400V, for 11kW 3-phase induction motors
AC-4 Rated Current11OFor severe duty such as direct starting and reversing of squirrel-cage motors
Capacitate de rupereAC-3 400V: 150cel; AC-3 660V: 35celMeets industrial short-circuit breaking requirements
Parametrii bobinei
Tensiunea bobineiAC230V 50/60HzStandard 0XM0 configuration, coil power approx. 12VA
Tip bobinăAC electromagnetic coilStable pull-in, strong anti-interference
Mechanical / Viața electrică
Viața mecanică≥ 12,000,000 operațiuniNo-load frequent operation, suitable for high-cycle applications
Viața electrică≥ 1,000,000 operațiuni (AC-3)Long-term reliable operation at 22A / 400V
Mediu & Protecţie
Temperatura de operare-25°C ~ +55°CWide temperature range for outdoor, workshop and harsh environments
Ingress ProtectionIP20Finger-safe, suitable for panel mounting
MontareTH35 standard railQuick installation, compatible with standard distribution boards
Approval Standards
ConformitateIEC 60947-4-1, GB 14048.4Globally recognized certifications, safe and reliable
  1. Funcții de bază & Design Advantages
  2. Double-break Arc Extinction System: Main contacts feature double-break structure, strong arc quenching, reliable breaking, extended contact life
  3. Modular Accessory Compatibility: Supports add-on auxiliary contact blocks, shunt trips, undervoltage trips, mechanical interlocks, etc.
  4. Terminale cu șuruburi: Reliable screw connection for main circuit, suitable for high-current wiring; auxiliary terminals available in spring or screw type
  5. Wide-range Coil Design: Universal pentru 50/60Hz, adaptable to global grids, reduces spare part variety
  6. Mechanical Position Indication: Clear ON/OFF status for on-site inspection and safe operation
  7. Aplicații tipice

Controlul motorului: Starting, stopping, forward/reverse control of 3-phase induction motors (≤11kW), de ex. pompe, fani, masini-unelte

Industrial Machinery: Main circuit control for packaging, textile, injection molding, conveyors and other equipment

Power Distribution: Branch circuit switching in distribution boards and power boxes, local/remote control

Automated Lines: Integrated with PLCs and relays for automatic control in continuous production lines

  1. Replacement Solutions (Key)

5.1 Siemens Original Replacement (Recomandat)

Model originalModel de înlocuireKey DifferencesCompatibilitate
3TF4322-0XM03RT6026-1AN20Same size, AC-3 22A, AC230V coil, 2NU+2NC; accessories not interchangeable, full replacement requiredPerfect drop-in replacement, identical mounting, performanță îmbunătățită
3RT5026-1AN20Same current rating, longer mechanical life, heavy-duty ratedDomestic 3RT5 series, replaces legacy 3TF

5.2 Cross-brand Alternatives

MarcaModel de înlocuireMatching Key ParametersAplicație
ABBAF16-30-013-pol, 22A AC-3, AC230V coilGeneral industrial, rentabil
SchneiderLC1D25M73-pol, 25A AC-3, AC230V coil, 2NU+1NCSlightly larger dimensions, verify mounting space
CHINTCJX1-22/223-pol, 22A AC-3, AC230V coil, 2NU+2NCDomestic alternative, significant cost advantage
  1. Instalare & Maintenance Guidelines

6.1 Specificații de instalare

Mount vertically on TH35 rail, maintain ≥10mm clearance to adjacent devices for heat dissipation

For 22A rated current, main circuit recommended copper cable ≥ 4mm², tightening torque approx. 2.5N·m

Route coil wiring away from main high-voltage circuits to avoid EMI; auxiliary terminal cable ≥ 1.5mm²

6.2 Recomandări de întreținere

Inspecție regulată (fiecare 6 luni): contact erosion, terminal tightness, coil insulation

Contact maintenance: replace main contacts if worn below 1mm; clean or replace auxiliary contacts if poor connection

Cleaning: Use compressed air to remove dust, prevent insulation degradation

Depanare: Coil fails to pull in → check voltage and wiring; contact burning → check load current and arc system

  1. Rezumat & Upgrade Suggestions
  2. Status: 3TF4322-0XM is discontinued by Siemens. 3RT6026-1AN20 is the preferred direct replacement with better performance and reliability.
  3. Selection Key: Strictly match number of poles, curent nominal, coil voltage and auxiliary contact configuration to ensure system compatibility.
  4. Upgrade Direction: For extended life or smart functions, select 3RT6 models with expanded auxiliary contacts and remote diagnostics for modern industrial control.

Siemens 3RT6 Series (Domestic SIRIUS) Contactor Model List

Key Overview: The 3RT6 series is Siemens’ official replacement for the legacy 3TF series. Classified by frame size (S00 / S0 / S000 / S1 / S2 / S3), it covers 7-110A AC-3 current, suitable for 3-phase motors up to 55kW, available in 3-pole / 4-pol, AC / DC coils, with extensive accessory support. Below is a list of commonly used full order numbers, sorted by frame size for general industrial use.

  1. Model Format & Core Parameter Explanation

1.1 Full Order Number Format

3RT6xxx-xxxxx (Exemplu: 3RT6026-1AN20)

SegmentSensCommon Codes
3RT6Cod de serieDomestic SIRIUS AC contactor, replaces 3TF series
016 / 017 / 025 / 026Size / Actual016=S00(9O); 017=S0(17O); 025=S000(25O); 026=S000(25O); 034=S1(38O)
1Main Contact Configuration1=3NO (3-phase NO); 2=3NC (3-phase NC, rare)
O / B / F / M / G / QTensiunea bobineiA=AC24V; B=DC24V; F=AC115V; M=AC230V; G=AC42V; Q=AC400V
20 / 21 / 22 / 40Contacte auxiliare20=1NO+1NC; 21=1NO; 22=1NC; 40=2NO+2NC (larger frames)

1.2 Core Parameter Quick Reference

Frame SizeAC-3 Current (400V)Motor RatingBuilt-in Aux. ContacteAplicație
S007–9A≤4kW1NU / 1NCSmall fans, pompe, electrovalve
S012–17A≤5.5–7.5kW1NU+1NCSmall-to-medium machine tools, transportoare
S00022–25A≤11kW2NU+2NC11kW motors, general industrial circuits (replaces 3TF43)
S132–38A≤18.5kWNone (add-on required)Medium motors, air compressors, pompe
S250–63A≤30kWNone (add-on required)Heavy equipment, main power distribution
S380–110A≤55kWNone (add-on required)Motoare mari, new energy applications
  1. 3RT6 Series Popular Models (3-pol, 3NO Main Contacts)

2.1 Frame S00 (7-9O, ≤4kW)

Full Order No.Tensiunea bobineiAC-3 CurrentAux. ContacteAplicație3TF Replacement
3RT6016-1AN21AC230V9O1NUSmall loads, solenoids3TF3000-0XM0
3RT6016-1AN22AC230V9O1NCSmall loads, solenoids3TF3001-0XM0
3RT6016-1BB41DC24V9O1NUControl PLC, low-voltage DC systems3TF3000-0BB4
3RT6016-1BF40DC110V9O1NO/1NCIndustrial DC control3TF3001-0BF4
3RT6016-1QF00AC400V9O1NUHigh-voltage control circuits3TF3000-0QF0

2.2 Frame S0 (12-17O, ≤5.5-7.5kW)

Full Order No.Tensiunea bobineiAC-3 CurrentAux. ContacteAplicație3TF Replacement
3RT6017-1AN20AC230V17O1NU+1NCSmall-to-medium motors, fani3TF3300-0XM0
3RT6017-1AN21AC230V17O1NUSmall-to-medium motors, fani3TF3301-0XM0
3RT6017-1BB40DC24V17O1NU+1NCControl PLC, sisteme DC3TF3300-0BB4
3RT6017-1AF00AC115V17O1NU+1NCIndustrial control, masini-unelte3TF3300-0AF0

2.3 Frame S000 (22-25O, ≤11kW, Key Replacement for 3TF43)

Full Order No.Tensiunea bobineiAC-3 CurrentAux. ContacteAplicațieKey Replacement Note
3RT6026-1AN20AC230V25O2NU+2NC11kW motors, general industrial circuitsDirect replacement for 3TF4322-0XM0, same size, upgraded performance
3RT6026-1AN21AC230V25O1NU11kW motors, general industrial circuitsReplaces 3TF4301-0XM0
3RT6026-1BB40DC24V25O2NU+2NC11kW motors, DC control systemsReplaces 3TF4322-0BB4
3RT6026-1QF00AC400V25O2NU+2NCHigh-voltage industrial circuitsReplaces 3TF4322-0QF0
3RT6025-1AC20AC24V25O2NU+2NCLow-voltage control, small equipment3TF4322-0AC2

2.4 Frame S1 (32-38O, ≤18.5kW)

Full Order No.Tensiunea bobineiAC-3 CurrentAux. ContacteAplicație
3RT6034-1AN20AC230V38O2NU+2NC18.5kW motors, air compressors
3RT6034-1BB40DC24V38O2NU+2NC18.5kW motors, sisteme DC
3RT6034-1AF00AC115V38O2NU+2NCIndustrial control, heavy equipment

2.5 Frame S2 (50-63O, ≤30kW)

Full Order No.Tensiunea bobineiAC-3 CurrentAux. ContacteAplicație
3RT6045-1AN20AC230V63O2NU+2NC30kW motors, pompe, main power distribution
3RT6045-1BB40DC24V63O2NU+2NC30kW motors, DC control systems
3RT6046-1AN20AC230V80O2NU+2NC45kW motors, heavy equipment

2.6 Frame S3 (80-110O, ≤55kW)

Full Order No.Tensiunea bobineiAC-3 CurrentAux. ContacteAplicație
3RT6054-1AN20AC230V110O2NU+2NC55kW motors, new energy, large industrial equipment
3RT6055-1BB40DC24V110O2NU+2NC55kW motors, high-voltage DC systems
  1. Popular 4-pole Models (3P+N, with Neutral Protection)
Full Order No.PoloniiTensiunea bobineiAC-3 CurrentAux. ContacteAplicație
3RT6026-1AN233P+N (4P)AC230V25O2NU+2NC11kW motors, loads with neutral
3RT6034-1AN233P+N (4P)AC230V38O2NU+2NC18.5kW motors, loads with neutral
3RT6045-1AN233P+N (4P)AC230V63O2NU+2NC30kW motors, loads with neutral
  1. Key Selection & Note de înlocuire

4.1 Direct 3TF-to-3RT6 Replacement Table (Miez)

Legacy 3TF ModelRecommended 3RT6 ReplacementKey MatchesDiferenţă
3TF3000-0XM03RT6016-1AN219O, AC230V, 1NUSame size, improved electrical life
3TF3300-0XM03RT6017-1AN2017O, AC230V, 1NU+1NCSame size, longer mechanical life
3TF4322-0XM03RT6026-1AN2025O, AC230V, 2NU+2NCPerfect drop-in, compatible mounting, capacitate de rupere mai mare
3TF4400-0XM03RT6034-1AN2038O, AC230V, 2NU+2NCUpgraded size for higher-power motors

4.2 Critical Selection Rules

  1. Coil voltage must match: AC coils use M/A/F/Q; DC coils use B/F to avoid burnout.
  2. Auxiliary contacts as needed: S00/S0 have integrated contacts; S1 and above require 3RH series add-on blocks.
  3. Breaking class: Standard duty = S class (≤150kA@400V); heavy-duty / high short-circuit = K/H class.
  4. Extensie de accesorii: Supports shunt trip, declanșare la subtensiune, surge suppressors; accessories compatible with 3RT5/6 series.
  5. List Usage Instructions
  6. This list covers general industrial models. For special applications (explosion-proof, high protection), refer to Siemens’ official full catalog.
  7. La înlocuire, strictly match poles, actual, coil voltage and auxiliary contacts to ensure mounting and system compatibility.