Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

Schneider Electric C125N420FM Molded Case Circuit Breaker - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

ŞtiriȘtiri comerciale

Schneider Electric C125N420FM Molded Case Circuit Breaker

Prezentare generală a produsului & Model Breakdown

C125N420FM is a 4‑pole molded case circuit breaker from Schneider Electric’s ComPacT NS1250N series, equipped with a MicroLogic 2.0 control unit.

It is used for overload and short‑circuit protection in low‑voltage power distribution systems, widely applied in industrial plants, clădiri comerciale, and infrastructure projects.

Segmentul de modelDescriere
C125NComPacT NS1250N series, frame size 1250A, breaking capacity 50kA@415VAC
44‑pole configuration (4P)
20MicroLogic 2.0 control unit (funcții de protecție de bază)
FMFixed mount, manual operation, front connection
  1. Core Technical Specifications
ArticolValoareNote
ModelSchneider Electric C125N420FMFull description: ComPacT NS1250N 4P 1250A 50kA MIC2.0
Frame current1250OMaximum rated operational current
Poles4 stâlpi (4P)3 phases + protectie neutra
Trip unitMicroLogic 2.0Long‑time (L), short‑time (S), instantaneous (eu) protecţie
Curent nominal (Ir)1250OAdjustable via trip unit
Ultimate breaking capacity (Icu)50kA@415VACComplies with IEC 60947‑2
MountingFixed, front connectionSuitable for standard switchgear
OperationManualWith mechanical indication and lockability
Tensiunea nominală de izolație (Ui)1000VACIEC 60947‑2
Rated operational voltage (Ue)400/415VAC (50Hz)Standard 3‑phase voltage
Short‑time withstand current (Icw/1s)50celEnsures system stability during faults
Protection degreeIP30Protection against solid foreign objects
Wiring capacityMax. 300mm² copperFor high‑current loads
  1. Caracteristici & Avantaje
  2. Comprehensive protection

MicroLogic 2.0 provides 3‑stage protection (L‑S‑I) with adjustable settings.

Supports fault diagnostics and alarm output for easy maintenance.

  1. Efficient design

Green “T” design reduces panel wiring time by 40%.

Ergonomic operating handle for improved safety and comfort.

Modular structure supports accessories: contacte auxiliare, alarm contacts, undervoltage release, etc.

  1. Reliable performance

50kA high breaking capacity for fast fault interruption.

Durata de viata mecanica: până la 10,000 operațiuni; electrical life: până la 5,000 operațiuni.

Ambient temperature: −5°C to +40°C (full rating), −25°C to +70°C (derated).

  1. Instalare & Applications

4.1 Cerințe de instalare

Suitable for standard distribution boards with industry‑standard mounting depth.

Front connection for easy wiring and maintenance.

Sufficient heat dissipation space required for stable long‑term operation.

4.2 Aplicații tipice

Incoming protection for main power distribution boards in industrial plants

Power distribution systems for large commercial complexes

UPS input/output protection in data centers

Critical load protection in infrastructure (hospitals, airports, metros)

Main protection for Motor Control Centers (MCC)

  1. Related Models & Alternative

5.1 Derived models in the same series

ModelDiferenţăApplication
C125N320FM3 stâlpi (3P)3‑phase loads without neutral protection
C125N450FMMicroLogic 5.0 trip unitEnergy measurement and advanced protection
C125N420PMDraw‑out installationEasy maintenance without power interruption
C125N420RMPlug‑in installationFast replacement for backup equipment

5.2 Cross‑series alternatives

ReplacementSerieMain differencePreț de referință
NSX1250N 4P MIC2.0ComPacT NSXNew generation, breaking capacity 65kAAproximativ. +10%
Masterpact MTZ12Masterpact MTZAir circuit breaker for higher power systemsAproximativ. +50%

5.3 Competitive brand equivalents

MarcaReplacementRating
Siemens3WL1212‑3CB36‑4GA41250A 4P 50kA basic protection
ABBTmax T6H1250 PR221DS‑LSI 4P1250A 4P 50kA LSI protection
EatonNZM4‑1250N 4P1250A 4P 50kA basic protection
  1. Purchasing & Sfaturi de utilizare
  2. Authentic procurement: Purchase via authorized Schneider Electric distributors or official channels to ensure quality and service.
  3. Accessories: Optional auxiliary contacts, alarm contacts, excursie cu șunt, undervoltage release, etc.
  4. Parameter setting: MicroLogic 2.0 can be programmed; adjust according to load characteristics.
  5. Întreţinere: Routine inspection every 1–2 years, including mechanism, terminals, and protection functions.

> Nota: C125N420FM complies with IEC 60947‑2, GB 14048.2 and other international & national standards. It is fully compatible with Schneider Prisma E, Blokset and other panel systems.

  1. Selecţie & Replacement Guidelines
  2. Compatibility Rules

Industrial relay sockets follow international standard dimensions and are interchangeable across brands if:

Pin count matches relay pole number

Curent nominal (≥10A) meets load

Mounting (DIN-rail/screw) matches panel design

  1. Terminal Type Selection

Conventional screw: PTF08A / PTF11A / PTF14A-suitable for low-vibration environments

Finger protection: PTFZ series-suitable for areas with frequent access

Push-In Plus: PTF-PU series-ideal for mass wiring, high vibration resistance

  1. Discontinued Models

PTF08A-E / PTF14A-E are discontinued with limited stock.

Use PTFZ series as the preferred replacement.

> Nota: PTF series sockets are rated 10A/250VAC, dielectric strength AC 2000V, operating temp −25 °C to +55 °C, suitable for 0.5–2.5 mm² copper wires.

Prev:

Următorul:

Lasă un răspuns

Lăsaţi un mesaj