Releu de supratensiune/subtensiune din seria Schneider EZ9C1263 Easy9

  1. Releu de supratensiune/subtensiune din seria Schneider EZ9C1263 Easy9

    Releu de supratensiune/subtensiune din seria Schneider EZ9C1263 Easy9

    Interpretarea modelului

Model ComponentSens
EZ9Easy9 Series (Schneider‘s cost-effective series for residential/commercial low-voltage terminal power distribution)
CVoltage control relay (with overvoltage/undervoltage protection function)
12Function type code (representing overvoltage/undervoltage protection + automatic reclosing function)
63Rated current 63A
No suffix2P (1P+Ns) pole configuration, suitable for 230VAC single-phase circuits
  1. Parametrii tehnici de bază
Categoria parametrilorValoareObservații
Product TypeOvervoltage/undervoltage relay (with automatic reclosing)Not a miniature circuit breaker, must be used in conjunction with MCB
Numărul de pol2P (1P+Ns, phase line + neutral line)Breaks phase line and neutral line simultaneously to provide complete protection
Curent nominal (În)63OSuitable for loads below standard 63A
Tensiune nominală de operare (Ue)230V AC 50HzApplicable to single-phase residential/commercial power supply systems
Overvoltage Protection Setting Value275V (tripping time: 3-15s)Graded protection to prevent equipment damage caused by overvoltage of varying degrees
300V (tripping time: 1-5s)
350V (tripping time: 0.25-0.75s)
400V (tripping time: 0.1-0.2s)
Undervoltage Protection Setting Value170V (tripping time: 3-15s)Prevents abnormal operation of equipment due to low voltage
150V (tripping time: 1-5s)
130V (tripping time: 0.25-0.75s)
Reclosing FunctionAutomatic reclosing, maxim 3 reclosing attemptsInterval between each reclosing is about 1 minute to prevent frequent reclosing
Protection CharacteristicGraded time-delay protectionAvoids maloperation caused by instantaneous voltage fluctuations
Tensiune nominală de izolație (Ui)440V șiComplies with IEC 60947-4-1 standard
Clasa de protectieIP20Previne contactul degetelor cu piesele sub tensiune, suitable for distribution box installation
Operating Ambient Temperature-5掳C~+60掳CNo derating required during use
Metoda de instalareDIN rail mounting (35mm șină standard)Compatible with other products of Easy9 series for convenient installation
DimensiuniModule width: 2 modules (about 36mm)Compact design, economisind spațiu în cutia de distribuție
Service LifeDurata de viata mecanica: 50,000 operațiuniComplies with IEC 60947-3 standard
Durata de viata electrica: 20,000 operațiuni (at rated current of 63A)

III. Core Functional Features

  1. Dual Overvoltage/Undervoltage Protection

Overvoltage Protection: Automatically disconnects the circuit when voltage exceeds 275V (±10V) to prevent electrical appliances from being damaged by overvoltage.

Undervoltage Protection: Automatically disconnects the circuit when voltage is lower than 170V (±10V) to avoid burnout of motors and other equipment due to undervoltage overload.

Graded Time Delay: Automatically adjusts tripping time according to the degree of overvoltage/undervoltage to improve protection accuracy.

  1. Automatic Reclosing Function

Automatically recloses after voltage returns to normal without manual intervention.

Maximum reclosing attempt limit (3 ori) to prevent frequent reclosing when faults persist.

Reclosing interval is about 1 minute to ensure circuit stability before reconnection.

  1. Safety Design Highlights

Fault Lockout: Automatically locks in the open position after 3 failed reclosing attempts, requiring manual reset.

Test Button: Manually tests whether the protection function is normal to ensure equipment reliability.

Arc-free Design: No arc ejection during breaking, improving operational safety.

Cooperative Operation with MCB: Must be installed downstream of MCB to utilize MCB for short-circuit and overload protection.

  1. Installation and Application Key Points
  2. Cerințe de instalare

Locația de instalare: Must be installed downstream of the miniature circuit breaker (MCB) as a secondary protection device.

Metoda de cablare: Strictly distinguish phase line (L) and neutral line (N), with clear markings on wiring terminals.

Installation Direction: Vertically installed on 35mm standard DIN rail, with wiring available at both upper and lower ends.

Condiții de mediu: Install in a well-ventilated and dry place, evitând umiditatea, dust and corrosive gases.

  1. Scenarii de aplicare
Application FieldTypical Usage
Distribuția de energie rezidențialăMain distribution box of households, protecting air conditioners, frigidere, TVs and other household appliances from voltage fluctuation damage
Clădiri ComercialeOffices, shops, hotel guest rooms, etc., protecting computers, printers and other office equipment
Small-scale IndustryControl circuits of single-phase equipment, protecting PLC, frequency converters and other precision electronic devices
Photovoltaic SystemsFront end of single-phase grid-connected inverters, protecting inverters from grid voltage fluctuations
  1. Recommended Supporting Equipment

MCB Matching: It is recommended to use Schneider Easy9 series EZ9F53263 (2P 63A C-curve, breaking capacity 6kA).

Cutie de distribuție: Easy9 series compact distribution box with IP43 protection class, suitable for rail mounting.

Wiring Terminals: Use copper lugs for connection to ensure good contact and reduce heating risk.

 

  1. Selecție și soluții alternative
  2. Puncte cheie ale selecției

Confirm circuit type: Only applicable to 230VAC single-phase circuits; other models should be selected for three-phase circuits.

Match load current: Rated current ≥ maximum load current; 63A is recommended for residential main protection.

Use with MCB: Must be used in conjunction with MCB and cannot be used alone as a circuit protection device.

  1. Alternative Model Reference
Demand ScenarioRecommended ModelDifference Description
No Reclosing RequiredEZ9C1163Only overvoltage/undervoltage protection, without automatic reclosing function
40A Rated CurrentEZ9C1240Suitable for branch circuit protection with small load current
Integrated Leakage ProtectionEA9ZGQ263Integrated design of overvoltage/undervoltage + leakage protection + automatic reclosing
Three-phase CircuitsSelect Acti9 series voltage relayApplicable to 400VAC three-phase circuits
  1. Fault Diagnosis and Maintenance
Fenomen de eroareCauze posibileTroubleshooting Methods
Declanșări frecventeLarge grid voltage fluctuations; low setting value; abnormal loadCheck grid quality; adjust setting value; troubleshoot load faults
No ActionWiring error; power supply failure; relay damageVerify wiring diagram; check power supply; replace the relay
Reclosing FailurePersistent faults; exceeded reclosing attempt limitTroubleshoot circuit faults; manually reset before reconnection
Abnormal HeatingLoose wiring; load overload; excessively high ambient temperatureTighten wiring; check load; improve ventilation conditions

Rezumat

Schneider EZ9C1263 is an overvoltage/undervoltage relay specially designed for 230VAC single-phase circuits. Its core advantage lies in the automatic reclosing function, which can automatically restore power supply after voltage returns to normal, improving the convenience of electricity use. As a member of the Easy9 series, its compact design, DIN rail mounting and high reliability make it an ideal choice for protecting precision electronic equipment in residential and small-scale commercial buildings. It should be noted that this product is not a miniature circuit breaker and must be used in conjunction with MCB to achieve complete short-circuit, overload and voltage protection functions.