A9L612301 is a pluggable Type T1+T2 Surge Protection Device (СПД) of the iPRF1 12.5r 3P model under Шнайдер‘s Acti9 series. It features both Class I and Class II test classifications with 3 столбы, making it suitable for lightning and surge protection in three-phase distribution systems. It supports remote status indication and enables convenient installation and maintenance. Below is a detailed explanation of its core parameters, installation key points, replacement selection, and troubleshooting:
| Параметр Элемент | Ценить |
| Модель продукта | iPRF1 12.5r 3P |
| Test Classification | Class I + Class II (T1+T2) |
| Impulse Current (Iimp) | 12.5тот (common mode L – ЧП) |
| Номинальный ток разряда (В) | 20тот |
| Максимальный ток разряда (Imax) | 50тот |
| Максимальное непрерывное рабочее напряжение (УК) | 350В и |
| Номинальное рабочее напряжение (Уэ) | 230/400В и (±10%), 50/60Гц |
| Уровень защиты напряжения (Вверх) | ≤1.5kV |
| Номер полюса | 3П |
| Remote Indication | 1 Changeover Contact (1C/O) |
| Способ монтажа | 35mm standard DIN rail |
| Ширина Размер | 3 модули (27мм) |
Особенности продукта & Сценарии применения
- Особенности продукта
Integrated Protection: T1+T2 composite protection eliminates the need for additional graded SPDs, saving space and cost.
Pluggable Design: The module supports hot plugging and unplugging under live conditions, enabling quick replacement in case of failure without affecting the power supply of the main circuit.
Visual Status Indication: Built-in remote indication contact can be connected to the monitoring system to feed back the operating status of the SPD in real time, facilitating operation and maintenance.
Safe and Reliable: Built-in thermal trip and overcurrent protection prevent short-circuit risks caused by SPD faults.
- Сценарии применения
It is applicable to the incoming ends of three-phase distribution systems or the front ends of important equipment in industrial plants, commercial buildings, data centers, и т. д., protecting electrical equipment from damage caused by direct lightning strikes, induced lightning, and operating overvoltage.
Key Installation & Wiring Points
- Installation Preparation
Confirm the installation position on a 35mm standard DIN rail, reserve sufficient heat dissipation space, and avoid close proximity to heating elements.
Verify the matching of system voltage, frequency and SPD parameters; Uc shall be higher than the maximum operating voltage of the system.
- Характеристики проводки
The incoming end is connected to the power supply side, and the outgoing end to the load side; L1, L2 and L3 correspond to the three-phase live wires, and PE shall be reliably earthed.
The wire diameter of the connecting conductor shall be no less than 16mm² copper core wire, and the length shall be as short as possible (≤50cm) to reduce the impact of wire resistance on protection performance.
The remote indication contact is connected to the monitoring circuit, with the rated current not exceeding AC 12 6A/240V and DC 12 2A/48V.
- Примечания
It shall be used in conjunction with a backup protection circuit breaker; the rated current of the circuit breaker is recommended to be 16A 32A to avoid selective tripping caused by SPD faults.
Поиск неисправностей & Maintenance
| Явление неисправности | Possible Cause | Troubleshooting Method |
| Remote indication contact actuation | SPD module damage | Replace the iPRF1 12.5r 3P module after power off |
| Severe heating of SPD | Loose wiring or poor contact | Check the wiring terminals, retighten them to ensure reliable connection |
| Unable to plug or unplug the module | Damaged DIN rail buckle | Replace the DIN rail or repair the buckle; avoid forced plugging/unplugging to prevent module damage |
Cross-brand Replacement Selection
For replacement of this model, the following products of the same grade can be referred to. Ensure the consistency of key parameters during replacement:
- АББ: OVR T1+T2 20 350 3П, In=20кА, Imax=50kA, Uc=350В, 3П, with remote indication.
- Сименс: 5SD7432 0, Type T1+T2, In=20кА, Imax=50kA, Uc=350В, 3П, suitable for standard DIN rail.
- Schneider same-series replacement: A9L16633 (iPRF1 12.5r 3P, with remote indication), which is completely consistent in function with A9L612301 and can be directly interchanged.
Selection & Предложения по закупкам
- Confirm that the system is a three-phase distribution system; for a 3P+N system, A9L16634 (iPRF1 12.5r 3P+N) is optional.
- Check the product batch number and anti-counterfeiting mark during procurement to ensure genuine Schneider original products and avoid the impact of counterfeit products on protection performance.
- For bulk procurement, consult authorized Schneider distributors to obtain better prices and technical support.
Parameter Comparison Between A9L612301 and A9L16633 (Основной вывод: Fully consistent in function, can be directly interchanged)
| Параметр Элемент | A9L612301 | A9L16633 | Описание разницы |
| Модель продукта | iPRF1 12.5r 3P | iPRF1 12.5r 3P | Идентичный |
| Test Classification | Class I + Class II (T1+T2) | Class I + Class II (T1+T2) | Идентичный |
| Impulse Current (Iimp) | 12.5тот (common mode L-PE) | 12.5тот (common mode L-PE) | Идентичный |
| Номинальный ток разряда (В) | 20тот | 20тот | Идентичный |
| Максимальный ток разряда (Imax) | 50тот | 50тот | Идентичный |
| Максимальное непрерывное рабочее напряжение (УК) | 350В и | 350В и | Идентичный |
| Номинальное рабочее напряжение (Уэ) | 230/400В и (±10%), 50/60Гц | 230/400В и (±10%), 50/60Гц | Идентичный |
| Уровень защиты напряжения (Вверх) | ≤1.5kV | ≤1.5kV | Идентичный |
| Номер полюса | 3П | 3П | Идентичный |
| Remote Indication | 1 Changeover Contact (1C/O) | 1 Changeover Contact (1C/O) | Идентичный |
| Способ монтажа | 35mm standard DIN rail | 35mm standard DIN rail | Идентичный |
| Ширина Размер | 3 модули (27мм) | 3 модули (27мм) | Идентичный |
| Technical Type | MOV+GDT composite technology | MOV+GDT composite technology | Идентичный |
| Индикация состояния | Зеленый (normal)/Красный (fault) | Зеленый (normal)/Красный (fault) | Идентичный |
| Certification Standard | МЭК 61643-11, ГБ 18802.1 | МЭК 61643-11, ГБ 18802.1 | Идентичный |
| Production Batch | Old batch | New batch | Only different in batch, no functional difference |
Same-series 3P+N Model Replacement Adaptation List (A9L612301 is 3P, the following are corresponding 3P+N models)
| Модель | Product Name | Основные параметры | Adaptation Scenario | Replacement Description |
| A9L16634 | iPRF1 12.5r 3P+N | Type T1+T2, Iimp=12.5kA, In=20кА, Imax=50kA, Uc=350В, 4 модули (36мм), with remote indication | Three-phase four-wire (3П+Н) distribution system, TN-S/TT earthing system | 3P+N version of A9L612301 with an increased width of 1 модуль; confirm the distribution box space |
| A9L612302 | iPRF1 12.5r 3P+N | Identical to A9L16634 | Three-phase four-wire (3П+Н) distribution system | Old batch 3P+N version of A9L612301 |
Key Notes for Replacement Selection
- Selection of 3P and 3P+N: Select according to the system type; 3P is applicable to three-phase three-wire systems, and 3P+N is applicable to three-phase four-wire systems (TN-S/TT).
- Installation Space Confirmation: The width of the 3P model is 27mm (3 модули), and that of the 3P+N model is 36mm (4 модули). Ensure sufficient installation space in the distribution box during replacement.
- Backup Protection Coordination: The 3P+N model shall also be used with a 16A-32A circuit breaker to ensure protection coordination.
- Remote Indication Wiring: The remote indication contact of the 3P+N model is completely the same as that of the 3P model, and the original wiring can be directly reused.
- Earthing System Compatibility: The 3P+N model is applicable to TN-S and TT earthing systems, while the 3P model is applicable to all three-phase earthing systems.
Schneider A9L612301 (iPRF1 12.5r 3P) Cross-brand Model Comparison
Core Parameter Benchmark: T1+T2 composite protection, Iimp=12.5kA(10/350μs), In=20кА(8/20μs), Imax=50kA(8/20μs), Uc=350В, 3 столбы, with remote indication, pluggable design, 35мм Монтаж на DIN-рейку
- International Mainstream Brand Comparison Table
| Бренд | Модель | Основные параметры | Особенности продукта | Replacement Notes |
| АББ | OVR T1-T2 3L 20-350 П ТС КС | T1+T2, Iimp=12.5kA, In=20кА, Imax=50kA, Uc=350В, 3П, with remote indication (ТС) | Pluggable module, green/red status indication, thermal trip protection, соответствует МЭК 61643-11 | Installation width 27mm(3 модули), completely consistent with Schneider; 16A-32A circuit breaker is recommended for backup protection |
| (Заказ №.: 2CTB815710R2800) | ||||
| Сименс | 5SD7413-0 | T1+T2, Iimp=12.5kA, In=20кА, Imax=50kA, Uc=335V, 3П, with remote indication | Compact design, zero leakage current technology, automatic disconnection from the main circuit in case of failure, all models are equipped with remote contacts | Uc=335V is slightly lower than Schneider’s 350V, applicable to 400V systems; installation width 27mm(3 модули) |
| (SENTRON Series) | ||||
| Феникс Контакт | FLT-SEC-T1+T2-3S-350/25-FM | T1+T2, Iimp=12.5kA, In=25kA, Imax=62.5kA, Uc=350В, 3П, with remote indication | Pluggable design, low residual voltage (≤1.5kV), anti-vibration locking device, compatible with CHECKMASTER testing tools | In=25kA is slightly higher than the benchmark with stronger protection capacity; installation width 36mm(4 модули), confirm the distribution box space |
| (Заказ №.: 2905470) | ||||
| Феникс Контакт | VAL-MS-T1/T2 350/12.5/3+0 | T1+T2, Iimp=12.5kA, In=20кА, Imax=50kA, Uc=350В, 3П, with remote indication | Varistor technology, support hot plugging and unplugging, floating remote contact, suitable for Class III-IV lightning protection buildings | Installation width 27mm(3 модули), fully compatible with Schneider, support replacement under live conditions |
| (Заказ №.: 2800182) | ||||
| Hager | SPA931 | T1+T2, Iimp=12.5kA, In=20кА, Imax=50kA, Uc=350В, 3П, with remote indication | Модульная конструкция, clear fault indication, compatible with all three-phase earthing systems, compliant with EN 61643-11 | Installation width 27mm(3 модули), 16A-32A is recommended for backup protection, consistent with Schneider in protection coordination |
- Well-known Domestic Brand Comparison Table
Бренд Модель Основные параметры Особенности продукта Replacement Notes Вкусный CDYN-I+II 3P 20-350 T1+T2, Iimp=12.5kA, In=20кА, Imax=50kA, Uc=350В, 3П, with remote indication Pluggable module, built-in thermal trip and overcurrent protection, compliant with GB 18802.1, экономически эффективный Installation width 27mm(3 модули), completely consistent with Schneider, compatible with domestic distribution boxes (Серия DZ47sY) Чинт NXU-I+II 3P 20-350 T1+T2, Iimp=12.5kA, In=20кА, Imax=50kA, Uc=350В, 3П, with remote indication Модульная конструкция, green/red status indication, automatic disconnection in case of failure, compatible with TN-S/TT earthing systems Installation width 27mm(3 модули), 16A-32A is recommended for backup protection, высокая стоимость исполнения (Куньлунь серии) Nader NXU1-3P/20-350 T1+T2, Iimp=12.5kA, In=20кА, Imax=50kA, Uc=350В, 3П, with remote indication Pluggable design, low residual voltage (≤1.5kV), good thermal stability, applicable to industrial and commercial buildings Installation width 27mm(3 модули), compatible with Schneider products in dimension, equivalent protection performance (Surge Series) Key Notes for Replacement Selection
- Parameter Matching Priority
Must ensure: Uc≥maximum operating voltage of the system (350V is applicable to 400V systems)
Key matching: Test classification (T1+T2), Iimp, В, Imax, pole number are completely consistent
Functional matching: Remote indication contact type (1C/O), pluggable design
- Установка & Space Confirmation
The width of the standard 3P model is 27mm(3 модули), and that of the 3P+N model is 36mm(4 модули)
Check the DIN rail space and heat dissipation conditions of the distribution box during replacement, and avoid close proximity to heating elements
- Backup Protection Coordination
All models shall be used with a 16A-32A Type D circuit breaker to ensure protection coordination
The use of Type C circuit breakers is prohibited to avoid maloperation during lightning strikes
- Earthing System Compatibility
The 3P model is applicable to all three-phase earthing systems (TN-C/TN-S/TT)
The 3P+N model is only applicable to TN-S/TT systems, attention shall be paid to the system earthing type
- Recommended Priority for Brand Replacement
| Priority | Бренд | Модель | Recommended Reason |
| 1 | АББ | OVR T1-T2 3L 20-350 П ТС КС | Fully matched parameters, good brand compatibility, perfect global service network |
| 2 | Сименс | 5SD7413-0 | Mature technology, zero leakage current design, consistent dimension with Schneider |
| 3 | Феникс Контакт | FLT-SEC-T1+T2-3S-350/25-FM | Slightly stronger protection capacity, supported by testing tools, widely used in industry |
| 4 | Delixi/Chint | CDYN-I+II 3P 20-350/NXU-I+II 3P 20-350 | High cost performance, first choice for domestic replacement, compatible with domestic projects |