АКС580-01-246А-4
- АКС580: АББ new generation general wall-mounted ЧРП ряд
- 01: Standard integrated wall-mounted unit (non-cabinet modular type 04)
- 246А: Номинальный выходной ток 246 А
- 4: 3-phase input voltage class 380~480 V AC
Optional protection suffixes:
No suffix = IP21 standard version; +B056 = IP55 high-protection dustproof and waterproof version
Размер кадра: Р8
Order material numbers: 3AUA0000080507 (IP21), 3AUA0000083582 (IP55)
- Номинальная мощность / Current Ratings (400 V Grid)
| Тип нагрузки | Выходной ток | Соответствующая мощность двигателя | Overload Specification |
| Стандартный / Light Load (Фанаты & Насосы) ILd | 234 А | 132 кВт | 110% для 1 min every 10 мин |
| Rated Nominal Current In | 246 А | 132 кВт | Continuous rated operation |
| Heavy Load (Конвейеры / Экструдеры) IHd | 206 А | 110 кВт | 150% для 1 min every 10 мин |
Apparent output capacity: 170 кВА; Overall efficiency ≥ 98%
III. Основные электрические параметры
- Входной источник питания
Phases: 3-фаза (3PH)
Напряжение: AC 380~480 V ±10%
Mains frequency: 47.5~63 Hz
Power factor correction: Built-in DC choke (стандарт для рамы R8)
- Output Drive
Выходное напряжение: 0~Uin (0~480 V)
Выходная частота: 0~500 Hz
Control algorithms: Scalar V/F + Sensorless Flux Vector Control
Torque performance: 100% rated torque available at 0.5 Гц; Torque response <10 ms
- Standard Built-in I/O Terminals (Onboard Control Board)
| Тип | Количество | Specification Description |
| Analog Input AI | 2 каналы | Switchable 0~10 V / 4~20 mA |
| Analog Output AO | 2 каналы | 0~10 V / 4~20 mA |
| Digital Input DI | 6 каналы | 24 VDC NPN/PNP compatible |
| Digital Output DO | 3 каналы | Relay dry contacts (250 ВАК / 2 А) |
| Коммуникационный порт | 1 × RS485 | Modbus RTU standard; expandable to Profinet/Profibus/EtherNet/IP |
| USB Port | 1 канал | PC commissioning, parameter upload & download |
- Full Standard Protection Functions
Перегрузка по току, перенапряжение, пониженное напряжение, перегрузка, IGBT overtemperature, motor stall, замыкание на землю, потеря фазы, защита от срыва, cooling fan fault, защита от короткого замыкания, parameter loss alarm.
- Механические размеры & Масса
IP21 Standard Wall-mounted (АКС580-01-246А-4)
Overall size: ЧАС 615 × W 270 × D 250 мм
Вес нетто: 21 кг
IP55 High-protection Model (ACS580-01-246A-4+B056)
Overall size: ЧАС 965 × W 300 × D 452 мм
Вес нетто: 77 кг
Монтаж: Вертикальный настенный монтаж; leave ≥200 mm ventilation space top and bottom for heat dissipation
- Environmental Operation Specifications
- Рабочая температура: -15℃ ~ +50℃ (derate output by 5% at 50℃)
- Хранилище / transport temperature: -40℃ ~ +70℃
- Класс защиты: Base IP21; upgrade to IP55 with +B056 option
- Высота: Full power up to 1000 м; снижать номинальные характеристики 1% per additional 100 м выше 1000 м
- Влажность: 5~95% RH, нет конденсата, нет агрессивного газа
- Standard Built-in & Дополнительные аксессуары
Factory Standard Built-in Components
Detachable Chinese assistant control panel
Integrated DC choke
Basic I/O control board, Модбус РТУ
Bottom cooling fan
Optional Expansion Parts
- Braking resistor / тормозной блок: Mandatory for high-inertia start-stop and overhauling loads
- Communication adapters: Профибус ДП, Profinet IO, ЭтерНет/IP
- EMC filters: Класс А / Класс Б, compliant with industrial EMC standards
- Внешний 24 V power supply module, remote panel extension cable
- Complete IP55 cabinet kit (model suffix +B056)
VII. Типичные сценарии применения
- ОВК & Очистка воды (Light Load 132 кВт)
Cooling fans, tunnel exhaust fans, constant-pressure water supply main pumps, sewage agitators, градирни; variable-torque energy-saving operation.
- Погрузочно-разгрузочные работы & Строительные материалы (Heavy Load 110 kW Class)
Ленточные конвейеры, bucket elevators, cement mixers, экструдеры, центрифуги; frequent start-stop and shock loads.
- Общее оборудование
Большие компрессоры, wire drawing machines, mixing mills, paper production lines; precise speed regulation + multi-speed logic.
- Горное дело & Порты
Belt transfer equipment, dust removal fans; ideal IP55 model for wide voltage tolerance and strong dust resistance.
VIII. Adjacent Power Model Comparison within the Same Series
| Модель | Номинальный ток | Standard Power | Heavy Load Power |
| АКС580-01-206А-4 | 206 А | 110 кВт | 90 кВт |
| АКС580-01-246А-4 | 246 А | 132 кВт | 110 кВт |
| ACS580-01-293A-4 | 293 А | 160 кВт | 132 кВт |
- Core Product Advantages
- Fully integrated functions: Built-in choke, Модбус, multi-channel I/O; ready for complete set without extra options
- Chinese assistant panel: Guided commissioning wizard, one-click motor identification
- Wide grid compatibility: Universal 380~480 V, compatible with domestic 380 V and overseas 400/440 V-сетки
- Dual control modes: Simple V/F control + бездатчиковый вектор, suitable for both fan and heavy-duty equipment
- Optional IP55 high protection; direct wall mounting outdoors or in humid workshops without separate control cabinet
- Comprehensive energy-saving algorithms: Sleep mode, flow optimization, soft start-stop, cutting fan and pump energy consumption by over 30%
- Compatible with mainstream industrial buses, seamlessly connected to PLC systems such as Siemens, Мицубиси, Инновации
- Установка ключа & Характеристики проводки
- Проводка главной цепи
Вход: L1/L2/L3 connected to 3-phase 380 В; Output U/V/W connected to 3-phase asynchronous motor; PE earth terminal reliably connected to cabinet ground.
- Control Cable Requirements
Route shielded analog signal cables separately with a minimum spacing of 30 cm from power cables; single-end shielding grounding for digital twisted-pair cables.
- Mandatory Heat Dissipation Rules
Vertical mounting for R8 frame; top ventilation gap ≥200 mm, side gaps ≥50 mm; blow filter screens monthly in dusty environments.
- Braking Selection Reminder
Braking resistors must be fitted for high inertia shutdown and overhauling loads, otherwise frequent DC overvoltage faults will occur.
- Quick Troubleshooting Checklist
- Overcurrent OL: Motor stall, output short circuit, cable earth breakdown, insufficient derating for heavy loads
- Overvoltage OV: No braking resistor fitted for inertial loads, transient grid high voltage
- Overtemperature OT: Blocked air ducts, ambient temperature over 50℃, неисправен вентилятор охлаждения
- Потеря фазы на выходе: Loose motor wiring, broken wire on U/V/W one phase
- Communication Loss: Poor shield grounding, missing bus terminating resistor
All Control Modes of ABB ACS580-01-246A-4
All ACS580 drives share one unified control core with no functional cuts for the 246 А (Рама R8) модель. Three major control categories are supported: Scalar V/F, Бездатчиковый вектор, Vector with Encoder, subdivided into 5 operation modes to cover fans/pumps, general heavy loads and high-precision positioning applications.
- Scalar V/F Control (Параметр 99.04 = SCALAR)
- Linear V/F (Default for Light Load Fans & Насосы)
Voltage rises linearly with frequency with uniform voltage boost from 0~50 Hz. Suitable for fans, blowers, pumps and general centrifugal loads.
Функции: Simple structure, multi-motor parallel drive (one VFD driving multiple asynchronous motors); weak low-speed torque, zero torque at 0 Гц.
Приложения: системы отопления, вентиляции и кондиционирования, constant-pressure water supply, multi-pump parallel systems.
- Quadratic V/F (Square Curve, Dedicated for Fans & Насосы)
Voltage increases proportional to the square of frequency, matching the torque characteristic of fans and pumps for optimal energy efficiency.
Функции: Greatly reduces motor excitation loss and reactive power under light load; even weaker low-speed torque.
Typical scenarios: Вентиляторы градирни, циркуляционные насосы, dust extraction blowers.
- Boostable Torque V/F (Voltage Boost V/F)
Raises output voltage at low frequencies to compensate insufficient low-speed torque.
Приложения: Ленточные конвейеры, mixing equipment, light starting resistance loads.
- Sensorless Flux Vector Control (Параметр 99.04 = SENSORLESS)
The primary general heavy-load control of ACS580; no encoder required, standard for this 246 A model with no extra options needed.
Основная производительность
- 100% rated torque output at 0.5 Гц; high starting torque to overcome static friction
- Torque response <10 ms, far superior dynamic speed regulation over V/F control
- Supports precise current limiting, anti-stall protection and continuous heavy-load operation
- Static & rotating motor identification supported, compatible with new and old motors
Applicable Loads
Конвейеры, миксеры, экструдеры, компрессоры, деревообрабатывающее оборудование, single heavy-duty motor drives.
Ограничения
Cannot maintain full torque at zero speed (0 Гц); precise closed-loop speed control unavailable without encoder feedback.
III. Vector Control with Encoder (Параметр 99.04 = ENCODER)
Requires optional FEN-01 / FEN-11 encoder interface module installed in the VFD expansion slot.
- Supports pulse encoders: HTL / TTL incremental encoders
- Closed-loop speed control with 100% continuous rated torque at 0 Гц
- Speed control accuracy ±0.01% of rated speed
- Enables simple positioning, jog operation and tension control
Приложения
Wire drawing machines, winding/unwinding equipment, high-precision transmission, machinery requiring zero-speed load holding.
- Two Operation Reference Modes (Speed Command Source, Independent of Above Motor Control Algorithms)
- Local Control (Panel Reference)
Frequency set via control panel knob / кнопки; local start-stop and speed adjustment for single-unit commissioning.
- Пульт дистанционного управления (External Reference, Mainstream for Engineering)
Speed commands and start-stop signals come from external channels with flexible combinations:
- Analog reference: AI1/AI2 (0–10 V / 4–20 mA)
- Multi-speed DI digital terminal reference: До 7 fixed preset speeds
- Pulse frequency reference (optional IO module required)
- Fieldbus reference: Модбус РТУ (стандартный), Профибус ДП, Профинет, ЭтерНет/IP, и т. д..
- PID closed-loop reference: Built-in process PID for closed-loop constant control of pressure/flow/temperature (core function for constant-pressure pump & fan water supply)
- Special Process Control Modes (Built-in Functions Based on Vector / V/F Core)
- PID Process Control
Independent onboard PID regulator; no external PLC required for automatic constant pressure and flow control of pressure, liquid level and temperature.
- Multi-pump Cycling Soft Start (HVAC Special Function)
One-drive-multiple circulating water supply, automatic alternation of main and auxiliary pumps, energy saving via sleep & wake-up logic.
- JOG Jogging Control
Low-speed jog triggered via DI terminals for equipment maintenance and commissioning.
- DC Pre-excitation
DC pre-magnetization before startup to boost instantaneous starting torque in vector mode.
- Stall / Anti-overcurrent Torque Limiting
Automatic torque limitation to avoid overcurrent faults under heavy load.
- Quick Selection & Distinction Table
| Тип управления | Encoder Required | Low-speed Torque | Типичное использование |
| Quadratic V/F | Нет | Низкий | Energy-saving control for fans & насосы |
| Linear V/F | Нет | Moderate | Multi-motor parallel driving |
| Бездатчиковый вектор | Нет | Высокий (Full torque at 0.5 Гц) | Конвейеры, миксеры, general heavy loads |
| Vector with Encoder | FEN Module Required | Ultra-high (Zero-speed torque holding) | Winding equipment, high-precision transmission & позиционирование |
Applicable Scenarios of Closed-Loop Vector Control with Encoder for ABB ACS580-01-246A-4
Preface
This control mode uses parameter code 99.04=ENCODER. Optional FEN-01 (HTL) / FEN-11 (TTL) incremental encoder modules are mandatory. Real-time speed feedback from the motor shaft encoder delivers three core advantages:
- Непрерывный 100% rated torque holding at 0 Гц (sensorless vector cannot hold load at zero speed)
- Speed control accuracy ±0.01% rated speed with no low-speed jitter or step loss
- Supports precise tension closed-loop control, multi-axis synchronization, simple positioning and constant-torque processes
Closed-loop vector control is only selected for working conditions requiring zero-speed load holding, high low-speed precision, stable tension, multi-axis synchronization and slip-free heavy start-stop. Стандартные вентиляторы, pumps and single ordinary conveyors can operate reliably with sensorless vector or V/F control only.
- Winding & Unwinding Industry (Most Typical High-power Application, Matching 132 kW Class 246 A Model)
Применимое оборудование
Paper rewinders, plastic film extrusion winders, rubber calender winding/unwinding machines, non-woven slitting machines, metal foil wire drawing & winding machines, cable stranding machines
Mandatory Process Requirements for Closed-Loop Vector
- Smooth low-speed startup and constant tension maintenance during shutdown; no loose rolls, stretching or material breakage at zero speed
- Automatic constant tension as roll diameter dynamically changes between large and small reels, speed follows upstream master machine
- No tension fluctuation during high-low speed switching to prevent wrinkling or stretching deformation of web materials
- Multi-section linkage: Synchronized operation of unwinding-traction-winding three axes
Open-loop Disadvantages: Insufficient low-speed torque without encoder leads to web slipping and out-of-control tension.
- Высокоточное позиционирование / Intermittent Reciprocating Heavy-duty Equipment
Применимое оборудование
Large gantry feeders, heavy plate translation positioning tables, stone cutting feeders, cement block stacking conveyors, large packaging reciprocating cross-cutting machines
Process Requirements
- Precise stop at target positions with minimal repetitive positioning error; frequent jog & inching maintenance operations
- No position shifting or slipping when stationary under full load
- No speed overshoot during acceleration & deceleration; no jitter or impact on heavy start-stop
III. High-inertia Overhauling / Vertical Lifting Constant-torque Loads (High-power 110/132 kW Heavy-duty Conditions)
Применимое оборудование
Downward mine belt conveyors, large bucket elevators, heavy vertical mixers, lifting silo discharge drives
Process Pain Points Unsolvable by Open-loop Control
Reverse load generated by material self-weight requires full torque braking maintained at zero shutdown speed; overhaul runaway and overvoltage alarms easily occur at low descending speeds. Encoder closed-loop corrects speed in real time to suppress regenerative impact and stabilize DC bus voltage with braking units.
- Multi-motor Synchronized Production Lines (Long-distance High-power Synchronous Transmission)
Применимое оборудование
Cement kiln chain conveyors, long-distance multi-drive mine belts, multi-layer drying synchronized roller tables, continuous metal pickling lines
Process Requirements
Rigid synchronization of multiple motors with minimal speed deviation across sections to avoid plate stretching, belt deviation and tearing. Closed-loop vector with encoder feedback achieves far superior multi-motor synchronization accuracy compared to open-loop sensorless vector.
- Heavy-duty Equipment for Extrusion, Kneading & High-viscosity Mixing
Применимое оборудование
Plastic single/twin-screw extruders, rubber internal mixers, chemical high-viscosity reactor agitators, main asphalt mixing machines
Process Requirements
- Extremely high starting resistance for low-temperature high-viscosity materials; full torque output at 0 Hz to avoid startup stalling
- Constant extrusion torque throughout operation for uniform output thickness
- No torque ripple under steady low-speed operation for consistent product thickness
- Centrifuges & High-speed Precision Rotating Equipment
Применимое оборудование
Large chemical separation centrifuges, high-speed paper dehydration centrifuges, large horizontal food centrifuges
Process Requirements
High-precision stable speed across wide speed ranges with minimal speed fluctuation during acceleration/deceleration. Real-time speed correction via encoder feedback at high operating speeds eliminates resonance and uneven material stratification.
VII. High-power Stenter, Параметр & Padder Equipment for Textile Printing & Dyeing
Применимое оборудование
High-power stenters, water squeezing & calendering machines, continuous dyeing long lines
Process Requirements
Synchronized drafting of multiple rollers without fabric stretching or shrinkage; zero-speed load holding during low-speed fabric threading to avoid fabric accumulation and slipping; stable tension throughout operation.
VIII. Scenarios Unsuitable for Closed-Loop Vector Control (Select V/F or Sensorless Vector Directly)
- Фанаты, градирни, циркуляционные насосы, dust extraction blowers (variable-torque loads with no zero-speed load holding demand)
- Single light-duty belt conveyors, small mixers, компрессоры (no high-precision synchronization or tension control requirements)
- One-drive-multiple parallel multi-motor systems (only scalar V/F control applicable; encoder closed-loop cannot support multi-motor parallel driving)
Quick Application Selection Reference Table
| Core Working Condition Requirement | Recommended Control Mode | Кодер (FEN Module) Необходимый |
| Фанаты, насосы, multi-motor parallel driving | Scalar V/F | Нет |
| Ordinary conveyors, миксеры, компрессоры | Бездатчиковый вектор | Нет |
| Winding/unwinding, tension control, zero-speed load holding | Closed-loop Vector with Encoder | FEN-01/FEN-11 Required |
| Многоосевая синхронизация, точное позиционирование, high-inertia overhauling loads | Closed-loop Vector with Encoder | FEN Module Required |
| High-viscosity extrusion, kneading, high-power centrifuges | Closed-loop Vector with Encoder | FEN Module Required |
Supplementary Supporting Hardware (ACS580-01-246A-4 R8 Frame)
- HTL incremental encoder: Select FEN-01
- TTL differential encoder: Select FEN-11
- Braking resistors / braking units must be fitted for high-inertia overhauling scenarios to eliminate regenerative overvoltage faults
Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи



















NH42-63-318x560.png)




