ABB ACS355 series general machinery drive, 0.37 кВт / 0.5 Hp., single-phase 200–240 V input, IP20 protection, rated output current 2.4 А. Suitable for speed control and energy-saving operation of small machinery.
1 Model Code Explanation
| Code Part | Значение |
| ACS355 | ABB general machinery drive series |
| 01Э | Protection class IP20, for installation in enclosed electrical cabinets |
| 02A4 | Rated output current 2.4 А |
| 2 | Single-phase 200–240 V AC (±10%), 50/60 Hz input |
2 Key Technical Data
| Элемент | Ценить |
| Rated power | 0.37 кВт (0.5 Hp.) |
| Rated output current | 2.4 А (at 40°C) |
| Input voltage / frequency | Single-phase 200–240 V AC (±10%), 50/60 Гц |
| Output voltage / frequency | Three-phase 0–240 V AC, 0–500 Hz |
| Protection class | IP20 (indoor cabinet installation) |
| Control method | Scalar control (V/f), built-in application macros |
| Overload capability | 150% of rated current for 60 с; 180% для 2 с |
| Cooling method | Natural cooling |
| Размеры (W×H×D) | 169×70×135 mm |
| Масса | Приблизительно. 1.2 кг |
| Order code | 3AUA0000058166 |
| EMC performance | Built-in EMC filter, compliant with EN 61800-3 |
3 Key Features
3.1 Flexible Control
Predefined application macros: constant torque, fan/pump, PID control, и т. д..
Local/remote control switching via keypad, terminals or fieldbus
Built-in PID controller for closed-loop flow, pressure, и т. д..
3.2 Reliable Protection
Перегрузка по току, overload, перенапряжение, пониженное напряжение, перегрев, phase loss protection
Motor over-temperature protection (requires external PTC)
Short-circuit and earth-fault protection
3.3 Easy Operation
Compatible control panel with ACS350/510/550 series
Parameter copy function for fast commissioning
MTBF > 100,000 hours for continuous operation
4 Типичные применения
Small conveyors, packaging machinery
Fans, насосы (small HVAC systems)
Mixers, centrifuges and small processing machines
Automatic doors, roller shutters
Medical equipment, laboratory instruments
Textile, printing and other light industrial machinery
5 Установка & Commissioning Guidelines
5.1 Требования к установке
Must be installed in an enclosed electrical cabinet
Температура окружающей среды: 0–40°C (derate 10% at 40–50°C)
Mount vertically, keep ≥ 100 mm clearance above and below for cooling
Avoid dust, oil, corrosive gases
Input protection: 10 A MCCB (C-кривая) or fuse recommended
5.2 Basic Commissioning Steps
- Pre-power check: Verify wiring (L1/N input, U/V/W output), оконечный крутящий момент, proper earthing
- Parameter initialization
Group 99: set motor rated voltage, current, power, скорость
Select application macro (Standard, PID, и т. д.)
- Control configuration
Local control: via control panel
Remote control: via DI terminals or optional Modbus RTU
- Operation test
No-load test: run at 5–10 Hz, check rotation and stability
Load test: gradually apply load, verify current and temperature
Adjust acceleration/deceleration time (1–10 s recommended)
6 Cross-Brand Replacement Options (0.37 кВт, 1-phase 220 В, IP20)
| Бренд | Модель | Key Matching Points |
| Шнайдер | ATV12HU04M2 | 0.37 кВт, 1-phase 220 В, IP20, similar size |
| Сименс | V20 6SL3210-5BB12-5UV1 | 0.37 кВт, 1-phase 220 В, IP20, integrated EMC |
| Чинт | NVF2-0.37/2 | 0.37 кВт, 1-phase 220 В, IP20, economical alternative |
| ABB alternative | ACS150-01E-02A4-2 | Same power range, more compact design |
7 Selection & Maintenance Tips
7.1 Recommended Options
Braking function: optional braking resistor (75 Ой / 50 W recommended)
Communication: add RS485 module
Enhanced EMC: additional input EMC filter
7.2 Maintenance
Clean cooling channels every 6 месяцы
Check terminal torque annually
Avoid frequent starts/stops (≤ 20 times per day)
Storage temperature: -25°C to +60°C, dry environment
ABB ACS355-01E-02A4-2
Installation and Commissioning Manual
Overview: This manual provides complete instructions for safety, installation, wiring, parameter setting and commissioning of the ACS355-01E-02A4-2 drive (0.37 кВт / 0.5 Hp., single-phase 200–240 V) for general machinery speed control and energy saving.
1 Safety Instructions (Must Read)
1.1 Electrical Safety
Power-off procedure: Disconnect all power before installation, wiring or maintenance. Wait 5 minutes for internal capacitors to discharge.
Earthing: PE terminal must be reliably earthed (earth resistance ≤ 4 Ой)
Защита от перегрузки по току: Install 10 A MCCB (C-кривая) or fuse on input side
Испытание изоляции: Only test motor cables; do NOT apply voltage to the drive itself
1.2 Mechanical Safety
Rotating parts (shaft, coupling, pulley) must be guarded
Mount vertically on solid surface to avoid vibration
Do not modify internal circuits or structures
1.3 Environmental Safety
Рабочая температура: 0–40°C (derate 10% at 40–50°C)
Влажность: 5–95% RH, non-condensing
IP20: must be installed in enclosed cabinet
2 Product Overview and Model Identification
2.1 Model Explanation (ACS355-01E-02A4-2)
| Code | Значение |
| ACS355 | ABB general machinery drive series |
| 01Э | IP20, cabinet-mounted |
| 02A4 | Rated output current 2.4 А (40°C) |
| 2 | Single-phase 200–240 V AC, 50/60 Гц |
2.2 Основные характеристики
| Элемент | Ценить |
| Rated power | 0.37 кВт (0.5 Hp.) |
| Input voltage | Single-phase 200–240 V AC (±10%) |
| Output voltage | Three-phase 0–240 V AC |
| Output frequency | 0–500 Hz |
| Overload capacity | 150% для 60 с, 180% для 2 с |
| Cooling | Natural cooling |
| Размеры (W×H×D) | 169×70×135 mm |
| Масса | Приблизительно. 1.2 кг |
| Order code | 3AUA0000058166 |
3 Installation Procedure
3.1 Preparation
- Unpack and inspect drive for damage
- Choose well-ventilated, dust-free location inside cabinet
- Tools: крестовая отвертка (PH2), wire stripper, crimping tool, multimeter, insulation tape
3.2 Mounting
- Mount vertically on flat metal plate
- Keep ≥ 100 mm above/below, ≥ 50 mm left/right clearance
- Fix with M4 screws, tightening torque: 1.2–1.5 N·m
4 Electrical Wiring
4.1 Terminal Description (ACS355-01E Series)
| Section | Терминал | Описание | Электропроводка |
| Power Circuit | L1/N | Single-phase 200–240 V input | 1.5–2.5 mm² copper |
| ЧП | Protective earth | ≥ 2.5 mm² copper | |
| U/V/W | 3-phase output to motor | 1.5–2.5 mm² copper | |
| Схема управления | DI1–DI3 | Digital inputs | 0.5–1.5 mm², max 50 м |
| AI1/AI2 | Analog inputs (0–10 V / 0–20 mA) | Shielded twisted pair, max 100 м | |
| AO1 | Analog output (0–20 mA) | Shielded twisted pair, max 100 м | |
| +24V/GND | 24 V DC supply (max 100 мА) | 0.5–1.5 mm² | |
| RS485+/– | Modbus RTU | Shielded twisted pair, max 1000 м |
4.2 Wiring Steps
- Power wiring: L1/N to mains, PE to earth, U/V/W to motor
- Control wiring (Standard macro example):
DI1: Forward (FWD), DI2: Reverse (REV), DI3: Reset
AI1: Speed reference (0–10 V)
- Check torque, insulation, and phase sequence
5 Parameter Settings
5.1 Keypad Functions
▶/■: Начинать / Останавливаться
▲/▼: Adjust value
ENTER: Confirm
ESC: Back
LOC/REM: Local / Remote
5.2 Quick Motor Settings (Group 99)
| Параметр | Имя | Параметр | Примечание |
| 9901 | Language | Chinese / English | User choice |
| 9902 | Application macro | 1 (Standard) | General use |
| 9903 | Motor type | 1 (Asynchronous) | Standard induction motor |
| 9904 | Motor rated power | 0.37 кВт | From nameplate |
| 9905 | Motor rated voltage | 220/230/240 В | From nameplate |
| 9906 | Motor rated current | Motor nominal | Typically ~2.1 A |
| 9907 | Motor rated frequency | 50/60 Гц | From nameplate |
| 9908 | Motor rated speed | Motor nominal | ~1400–1450 rpm |
| 9909 | Number of motor poles | 4 | Standard for 0.37 кВт |
| 9910 | Control mode | 1 (V/f) | Scalar control |
5.3 Common Application Parameters
| Group | Параметр | Имя | Recommended Value |
| 10 | 1001 | Max frequency | 50/60 Гц |
| 1002 | Min frequency | 0 Гц | |
| 20 | 2001 | Acceleration time | 3–10 s |
| 2002 | Deceleration time | 3–10 s | |
| 21 | 2101 | Acc/dec type | 1 (Linear) |
| 40 | 4001 | DI1 function | 1 (FWD) |
| 4002 | DI2 function | 2 (REV) | |
| 4003 | DI3 function | 9 (RESET) | |
| 50 | 5001 | AI1 type | 1 (0–10 V) |
| 5002 | AI1 minimum | 0% | |
| 5003 | AI1 maximum | 100% | |
| 16 | 1607 | Save parameters | 1 |
6 Commissioning Flow
6.1 Pre-Power Check
Correct power and control wiring
Motor and drive area clear
Cabinet ventilation OK
Input voltage: 200–240 V single-phase
6.2 First Power-Up
Close MCCB, display shows REM or LOC
Check for fault codes
Verify Group 99 motor parameters
6.3 Motor Identification (Необязательный)
Set 9910 = 2 (ID Run)
Press ENTER; drive runs motor briefly
Completed when shown COMPLETE
6.4 No-Load Test
Switch to LOCAL
Run at 5 Гц, check rotation
Increase to rated frequency, check noise and vibration
6.5 Нагрузочный тест
Switch to REMOTE
Control speed via AI1
Check output current ≤ 2.4 А
Adjust acc/dec to avoid overcurrent
Test protection functions
7 Поиск неисправностей
7.1 Common Fault Codes
| Fault | Описание | Cause | Remedy |
| OVERCURRENT | Перегрузка по току | Motor overload, short circuit | Check load, мотор, parameters |
| OVERVOLTAGE | Overvoltage | High mains, fast deceleration | Check voltage, increase dec time |
| UNDERVOLTAGE | Пониженное напряжение | Low supply, loose connection | Check mains and wiring |
| OVERTEMP | Overheating | High temp, blocked cooling | Improve ventilation, clean heatsink |
| MOTOR OVERLOAD | Motor overload | Excessive load | Check application, reduce load |
| FAULT RESET | Trip reset required | Fault occurred | Fix cause, reset via DI3 or keypad |
7.2 Typical Issues
| Symptom | Cause | Solution |
| Motor does not start | Wrong LOC/REM, missing DI signal | Check mode, wiring and parameters |
| Unstable speed | AI noise, poor parameters | Use shielded cable, adjust filtering |
| Communication failure | Wrong settings, bad wiring | Check Group 98, RS485, termination |
8 Maintenance
8.1 Routine Maintenance
Clean cooling channels every 6 месяцы
Check terminal torque annually
Log operating current and temperature
8.2 Long-Term Storage
Температура: -25°C to +60°C
Dry, ventilated environment
Power on for 1 hour every 6 месяцы
9 Appendix: Options and Replacements
9.1 Recommended Options
Braking resistor: 100 Ой / 50 Вт
EMC filter
RS485 Modbus RTU module
Shielded cable for control wiring
9.2 Cross-Brand Alternatives (0.37 кВт, 1-phase 220 В, IP20)
| Бренд | Модель | Matching Features |
| Шнайдер | ATV12HU04M2 | 0.37 кВт, 1-phase 220 В, IP20 |
| Сименс | V20 6SL3210-5BB12-5UV1 | 0.37 кВт, 1-phase 220 В, IP20 |
| Чинт | NVF2-0.37/2 | 0.37 кВт, 1-phase 220 В, IP20 |
| АББ | ACS150-01E-02A4-2 | Direct same-power replacement |
Manual Version: V1.0 (based on ABB official ACS355 manual, adapted for ACS355-01E-02A4-2)