ALPHA6000M-S2R75GBRSM Mini Vector Inverter - Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер

Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

 ALPHA6000M-S2R75GBRSM Mini Vector Inverter - Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер

солнечный инвертор/ПЛК/

ALPHA6000M-S2R75GBRSM Mini Vector Inverter

ALPHA6000M-S2R75GB; RSM is a custom suffix (not defined in standard factory manuals. It usually stands for built-in braking resistor, fitted keypad, special firmware version or RoHS custom version. Confirm the definition of RSM with your supplier before ordering.) ✅ Model Code Breakdown ALPHA6000M: ALPHA6000M series, mini open-loop current vector inverter S2: Single-phase 220V input (200~240В ...

  • Подробная информация о продукте

ALPHA6000M-S2R75GB; RSM is a custom suffix (not defined in standard factory manuals. It usually stands for built-in braking resistor, fitted keypad, special firmware version or RoHS custom version. Confirm the definition of RSM with your supplier before ordering.)

✅ Model Code Breakdown

ALPHA6000M: ALPHA6000M series, mini open-loop current vector inverter

С2: Single-phase 220V input (200~240V AC)

R75: Matched motor power 0.75kW

Г: General-purpose load (constant torque)

Б: Встроенный тормозной блок. (supports external braking resistor)

RSM: Custom suffix (non-standard factory code)

✅ Key Electrical Specifications

Rated input: Single-phase AC 220V, 50/60Гц

Номинальная мощность: 3-phase 0~220V

Номинальный выходной ток: 4.0А

Режимы управления: Управление напряжением/частотой, Sensorless Open-loop Vector, V/F separation

Starting torque: 180% номинальный крутящий момент при 0,5 Гц

Speed regulation range: 1:200 in vector mode; 1:100 in V/F mode

Коммуникация: Встроенный RS485, Modbus-RTU

Max output frequency: 0~650Hz

Перегрузочная способность: 150% для 60-х, 200% на 3 секунды

Защита: Перегрузка по току, перенапряжение, пониженное напряжение, перегрев, перегрузка, потеря фазы, замыкание на землю, и т. д..

✅ Особенности продукта

Compact body, небольшой след, suitable for cabinets with limited installation space

AVR automatic voltage regulation, stable operation with ±20% grid voltage fluctuation

Supports motor parameter auto-tuning, strong low-frequency torque

Multiple programmable DI/DO, analog AI/AO, многоскоростной, ПИД, counting and other functions

Independent air channel for reliable heat dissipation. Widely used for assembly lines, фанаты, водяные насосы, конвейеры, small machine tools and other constant-torque applications

✅ Типичные применения

Малые конвейеры, упаковочное оборудование, фанаты & водяные насосы, производственные линии, маленькие экструдеры, деревообрабатывающее оборудование, оборудование для пищевой промышленности

✅ Замена & Совместимость

Альтернатива той же серии: ALPHA6000E-S2R75GB (6000E is standard version; 6000M is mini version. Pinout and dimensions differ, not direct plug-and-play)

Domestic equivalent models: Inovance MD200, Invt GD10, Delta VFD-M single-phase 220V 0.75kW models

Full Technical Package for ALPHA6000M-S2R75GBRSM

  1. Клеммы главной цепи (S2R75GB, single-phase 220V)
ТерминалФункцияОписание
л, НSingle-phase 220V inputAC200~240V power supply
+, ПБBraking resistor terminalsВстроенный тормозной блок.. Connect resistor between + and PB. Do NOT connect to DC negative (-)
ты, В, Вт3-фазовый выходConnect to 3-phase 220V asynchronous motor. Never connect mains power
ЧПЗащитная земляInverter and motor frame must be grounded together

Critical warning: Never connect L/N to U/V/W, this will destroy the inverter immediately; PB and + can only be connected with braking resistor, short-circuit is forbidden.

  1. Control Circuit Terminals (S2R4GB ~ S2R75GB)
ТерминалФункцияСпецификация
X1~X6Multi-function DI inputsDry contact, common terminal COM. Заводская настройка: X1 forward run, X2 reverse run
КОМDI common terminal24V reference ground
24ВExternal 24V DC supplyMax 100mA. Do not short to COM directly
10В+10V analog referenceMax 20mA, for potentiometer
ЗемляAnalog groundReference for AI/AO
AI1Аналоговый вход 10~10 В / 4~20 мА (selected by DIP switch), 0~20 мА, 250
AI2Аналоговый вход 2-10V~+10V voltage input
АО1, AO2Аналоговый выходConfigurable 0~10V or 4~20mA, selected by SW2 DIP switch
ДЕЛАТЬOpen-collector outputOpto-isolated, max 50mA, 0~50kHz pulse output
ОБЛИЦОВКА, туберкулез, ТКРелейный выходTA-TB NC; TA-TC NO; 250VAC/2A
485+, 485-Связь RS485Modbus-RTU, for PLC / HMI connection
ПЛКDI source selection terminalЗаводская настройка: PLC shorted with 24V for NPN mode; disconnect to use PNP

Common Wiring Schemes

  1. Potentiometer speed + terminal control: Potentiometer to 10V, AI1, Земля; short X1-COM = forward run
  2. 485 коммуникация: 485+ to A, 485to B; add termination resistor on remote side if needed
  3. Relay fault signal: TA-TC to PLC fault input
  4. Factory Reset Procedure (ALPHA6000M / 6000E compatible)
  5. Включение питания, press PRG to enter parameter menu
  6. Locate P0.02 (parameter initialization)
  7. Setting options:

0: Нет действий

1: Clear fault records

2: Restore factory defaults (рекомендуется)

  1. Подтверждать, wait for auto-reset. Power cycle to take effect

Frequently used basic parameters:

P0.01: Control mode 0=V/F, 2=open-loop vector (vector recommended)

P0.07: Run command source 0=keypad, 1=terminals, 2=communication

P0.03: Frequency reference source 0=keypad, 2=AI1, 8=multi-speed, 10=PID

P0.10: Max output frequency, default 50Hz, up to 650Hz

⚠️ Resistance below 100Ω will damage the built-in braking transistor. Mount resistor away from other components with sufficient clearance; resistor housing must be grounded.

Электропроводка: Connect resistor two wires directly between + and PB, not the “-” Терминал.

  1. Equivalent Replacement List (single-phase 220V 0.75kW mini vector, built-in braking unit preferred)

Примечание: ALPHA6000M is mini type. Pinout and mounting holes differ from 6000E standard version, нельзя поменять напрямую

Внутренние альтернативы

  1. Inovance MD200S0.75B (single-phase 220V, mini, built-in braking)
  2. Invt GD10-0R75-S2-B (GD10 mini series)
  3. Delta VFD007M21A (VFD-M classic small model)
  4. Sifang E310-2S0007
  5. Win-V63 0.75kW 220V single-phase

Примечания по замене

Priority check items: встроенный тормозной блок, DI/DO quantity, AO 4-20mA support, Модбус РТУ

Оригинальный блок: single-phase input, 3-phase 220V output. Replacement motor must be rated 220V 3-phase, cannot drive 380V motor directly

For easy parameter migration: ALPHA6000E-S2R75GB from same brand, but larger size and different mounting holes

  1. Fault Code Quick Reference (6000М)
Код неисправностиОписаниеПоиск неисправностей
ОКПерегрузка по токуКороткое замыкание двигателя, замыкание на землю, заблокированный ротор, слишком короткое время разгона
ОВПеренапряжениеБыстрое замедление, missing braking resistor, высокое напряжение сети
LVПониженное напряжениеПотеря входной фазы, low supply voltage, плохой контакт контактора
ОЙOverheatBlocked air channel, failed fan, высокая температура окружающей среды
ПРПерегрузка двигателяOverloaded machine, incorrect motor auto-tuning
CECommunication errorReversed 485 проводка, termination resistor, mismatched address / скорость передачи данных
  1. Motor Auto-Tuning (Mandatory for Vector Mode)
  2. Set P0.01=2 (разомкнутый вектор)
  3. Введите данные паспортной таблички двигателя: P2.00 rated power, P2.01 rated current, P2.02 rated frequency, P2.03 rated speed
  4. P2.04=1 (static auto-tuning, стационарный двигатель); P2.04=2 rotating auto-tuning (motor runs no-load, higher torque accuracy)
  5. Confirm and start; auto-tuning finishes automatically

ALPHA6000M Multi-speed + PID Constant Pressure Water Supply Parameter Set

For ALPHA6000M‑S2R75GB (0.75kW single-phase 220V)

Примечание: Do not activate both functions at once. PID is for constant pressure water / подача воздуха; multi-speed is for assembly lines, packaging machines and multi-position fixed speed switching.

Схема А: Multi-speed Control (DI speed selection, terminal start/stop)

Логика управления

Источник команды: Terminal run

Frequency source: Многоскоростной

DI assignment: X1 forward run, X2 reverse run, X3/X4/X5 as speed selectors (3-бит двоичный, до 8 скорости)

COM is DI common terminal, NPN mode (factory PLC shorted with 24V)

Parameter List

Param No.ИмяПараметрПримечания
P0.01Режим управления2Open-loop vector (рекомендуется); 0=V/F
P0.07Run command source1Terminal control (X1 forward / X2 reverse)
P0.03Frequency reference source8Multi-speed reference
P0.10Максимальная частота50Follow motor nameplate, max 650Hz
P0.11Min frequency0Adjust as required
P1.00Acc time 15Единица: с
P1.01Dec time 15Extend for frequent stopping
P3.00X1 function0Forward run
P3.01X2 function1Обратный ход
P3.02X3 function12Speed selector S1
P3.03X4 function13Speed selector S2
P3.04X5 function14Speed selector S3
P4.00Многоскоростной 010Скорость 0 (all S1S2S3 OFF)
P4.01Многоскоростной 115S1 ON
P4.02Многоскоростной 220S2 ON
P4.03Многоскоростной 325S1+S2 ON
P4.04Многоскоростной 430S3 ON
P4.05Многоскоростной 535S1+S3 ON
P4.06Многоскоростной 640S2+S3 ON
P4.07Многоскоростной 750S1+S2+S3 ON

Wiring Tips

No pressure / speed sensor required; only DI switch signals

If only 4 speeds are needed, use X3 and X4 only; X5 can be assigned to fault reset or other functions

Схема Б: PID Constant Pressure Water Supply (Замкнутый контур, 4-20mA pressure transmitter)

For small pump pressure stabilization. 4~20mA transmitter to AI1; 4mA = lower pressure, 20mA = full scale pressure

Output of this inverter is 3-phase 220V. Pump motor must be 3-phase 220V type, not 380V pump motor

Логика управления

Источник команды: Начало терминала (X1 forward run)

Frequency source: PID output

AI1: 4~20mA pressure feedback

PID setpoint: Keypad setting (or AI2 potentiometer setpoint)

Parameter List

Param No.ИмяПараметрПримечания
P0.01Режим управления0V/F preferred for pumps
P0.07Run command source1Terminal start X1 forward
P0.03Frequency reference source10PID reference
P0.10Максимальная частота50Pump rated frequency
P0.11Min frequency20Prevent dry running at low speed
P1.00Acc time10Avoid water hammer
P1.01Dec time15Pumps must not stop rapidly
P5.00PID enable1Enable PID
P5.01PID setpoint source0Keypad setpoint; 1=AI2 external setpoint
P5.02PID feedback source0AI1 feedback
P5.03PID proportional gain Kp30Initial value; reduce if oscillating
P5.04PID integral time Ti2Единица: с; increase if pressure fluctuates
P5.05PID derivative time Td0Derivative unused for water supply
P5.06PID deviation limit5Fast adjustment over this deviation
P5.07PID output upper limit100Corresponds to max frequency
P5.08PID output lower limit0
P5.09PID sleep function00=disable; 1=enable sleep at low flow
P6.00AI1 type selection11=4~20mA; 0=0~10V
P6.01AI1 min value0Pressure at 4mA (МПа)
P6.02AI1 max value1Pressure at 20mA (МПа), adjust as per transmitter

Электропроводка

Датчик давления: Powered by inverter 24V, signal+ → AI1, signal→ GND

Set AI1 DIP switch to current mode (4-20мА)

Short X1-COM to start; open to stop

PID Tuning Sequence (Важный)

  1. Disable PID first (P5.00=0), run pump manually to confirm rotation direction
  2. Confirm transmitter range: например. 0~1MPa, P6.01=0, P6.02=1.0
  3. P5.00=1 to enable PID, set target pressure on keypad e.g. 0.4МПа
  4. Поиск неисправностей:

Pressure oscillates: Reduce Kp (например. к 15), increase Ti

Pressure rises slowly: Increase Kp, reduce Ti

Severe overshoot: Reduce Kp, increase Ti

  1. Функция сна (P5.09=1): At low flow, when pressure exceeds setpoint for a period, inverter drops to min frequency then stops; restarts when pressure drops below wake-up threshold. Suitable for small water systems.

Switching Tip

Многоскоростной: P0.03=8

PID constant pressure: P0.03=10

Change P0.03 and power cycle inverter for best stability.

Full ALPHA6000M Series Model List (ALPHA Mini Vector Inverters)

  1. Правило кодирования модели

ALPHA6000M S2 R75 G B RSM

  1. С2: Single-phase 220V input; 3: 3-phase 380V input
  2. R75=0.75kW; 1R5=1.5kW; 2R2=2.2kW
  3. Г: General constant torque load; П: Вентилятор & pump variable torque load
  4. Б: Встроенный тормозной блок. (this model has B)
  5. RSM: RS485 Modbus communication option suffix

Важное примечание: S2R4GB and S2R75GB only support V/F, no SVC vector; higher power models support vector control

  1. Однофазный 220 В (S2 series, mini type, same family as your unit)

Стандартные модели (built-in braking unit GB)

  1. ALPHA6000M-S2R4GB | 0.4kW
  2. ALPHA6000M-S2R75GB | 0.75kW (base model of your unit)
  3. ALPHA6000M-S21R5GB | 1.5kW
  4. ALPHA6000M-S22R2GB | 2.2kW

With communication suffix RSM

S2R4GBRSM

S2R75GBRSM (твоя модель)

S21R5GBRSM

S22R2GBRSM

  1. 3-фаза 380В (3 ряд, dual rating G/P)

Small power integrated type (встроенный тормозной блок)

  1. ALPHA6000M-3R75GB/31R5PB | 0.75kW(Г)/1.5кВт(П)
  2. ALPHA6000M-31R5GB/32R2PB | 1.5kW(Г)/2.2кВт(П)
  3. ALPHA6000M-32R2GB/3004PB | 2.2kW(Г)/4кВт(П)
  4. ALPHA6000M-3004GB/35R5PB | 4kW(Г)/5.5кВт(П)
  5. ALPHA6000M-35R5GB/37R5PB-N | 5.5kW(Г)/7.5кВт(П)
  6. ALPHA6000M-37R5GB/3011PB | 7.5kW(Г)/11кВт(П)

Medium power (SJ suffix, external braking unit required)

  1. 3011GB/3015PB-SJ | 11/15kW
  2. 3015GB/3018PB-SJ | 15/18.5kW
  3. 3018GB/3022PB-SJ | 18.5/22kW
  4. 3022GB-SJ | 22kW

Вентилятор & pump only P type (no G rating)

3030P-N, 3037P-N, 3045P-N … up to 3630P-N

  1. ALPHA6000M vs 6000E (Справочник по замене)
  2. 6000М: Mini compact version

Max power 22kW; small S2 single-phase units, compact terminals; S2R4/S2R75 no vector support; smaller mounting cutout, not interchangeable with 6000E.

  1. 6000Э: Standard universal version

Power range 0.75~630kW; vector supported on all ratings; larger enclosure and mounting holes, incompatible with M series housing.

  1. Same Power Alternatives for S2R75GBRSM

Same series original: ALPHA6000M-S2R75GBRSM

Same power without communication: ALPHA6000M-S2R75GB

3-phase equivalent: 3R75GB (3-phase 380V input)

  1. Rated Current Table (Single-phase S2)
МодельВластьВходной токВыходной ток
S2R4GB0.4кВт5.1А2.4А
S2R75GB0.75кВт9.2А4.5А
S21R5GB1.5кВт13.1А7А
S22R2GB2.2кВт23А10А

Предыдущий: