Official Order No.:132F0022
⚠️ Important Notice: Данфосс FC51 series is approaching end-of-life. Final order cutoff date: 30 Jun 2026; final delivery cutoff date: 30 Sep 2026. Для новых проектов, evaluation of iC2-Micro as alternative is recommended.
- Model Code Decoding
| Код | Описание |
| ФК-051 | Серия продуктов: VLT Micro Drive FC51 compact general-purpose частотно-регулируемый привод |
| P2K2 | Rated power: 2.2 кВт (3 HP) |
| Т4 | 3-phase input, 380–480 V AC (50/60 Гц) |
| Е20 | Ingress protection rating: IP20 (chassis mounting, for cabinet internal installation) |
| Н3 | Built-in Class A1/B RFI filter (Category C1 environment) |
| Б | Integrated brake chopper (external brake resistor connectable) |
| Х | Without local control panel LCP (LCP11/LCP12 must be ordered separately if required) |
| С | PCB with conformal coating, suitable for humid and dusty harsh environments |
| XXX | No auxiliary power modules equipped |
| SXXX | Standard factory firmware version |
- Основные электрические параметры
Matched motor: 3-phase asynchronous motor, 2.2 кВт
Номинальный выходной ток: 5.3 А
Возможность перегрузки: 150% номинального тока для 60 секунды
Control modes: VVC+ vector control / U/f control
Диапазон выходной частоты: 0–200 Hz (VVC+); 0–400 Hz (U/f)
Коммуникация: Onboard RS485 (Модбус РТУ)
Размер кадра: М2
Вес нетто: 1.75 кг; Вес брутто: 1.95 кг
III. Standard Hardware Configuration
✅ Built-in EMC filter
✅ Integrated brake chopper
✅ Conformal coated printed circuit board
❌ No control panel supplied (commissioning requires external panel or MCT10 software)
❌ Brake resistor not included (to be ordered separately)
- Типичные применения
Фанаты, водяные насосы, конвейеры, упаковочное оборудование, небольшие станки, mixing equipment, textile machinery and other general constant-torque / variable-torque loads.
- Приобретение & Replacement Tips
- Stock availability is tight as FC51 enters end-of-life phase;
- Next-generation direct alternative model: iC2-Micro 2.2 кВт, 3-фаза 400 В;
- Optional panels for this unit:
LCP11: Digital panel (without potentiometer)
LCP12: Digital panel with built-in potentiometer;
- Wiring reminder: Maximum shielded motor cable length applies when the built-in H3 filter is activated.
ФК-051P2K2T4E20H3BXCXXXSXXX (Order No.132F0022|Frame M2, 2.2 кВт, 380 В) Full List of Compatible Accessories
The drive is delivered without control panel, brake resistor and door-mount kit. Below are original manufacturer compatible models sorted by application:
- Local Control Panels (Essential for Commissioning)
| Номер заказа. | Модель | Описание |
| 132B0100 | LCP11 | Digital control panel, without potentiometer, IP54 rated panel, for basic parameter setting and parameter copying |
| 132B0101 | LCP12 | Digital control panel with integrated potentiometer, supports local speed adjustment, preferred for on-site commissioning |
⚠️ Code X in model designation = panel excluded; panel must be purchased separately.
- Remote Door-Mount Kits for Control Panels
| Номер заказа. | Спецификация | Цель |
| 132B0112 | 1.5 m cable door mounting kit | Mount LCP11/LCP12 on control cabinet door |
| 132B0102 | 3 m cable door mounting kit | Long-distance cabinet door installation, including sealing assembly |
III. Защита & Mounting Upgrade Kits (For M2 Frame Only)
| Номер заказа. | Имя | Функция |
| 132B0109 | IP21 Protection Kit for M2 | Original unit IP20; protection class upgraded to IP21 (NEMA Type1) after installation |
| 132B0106 | De-coupling partition kit M1/M2 | Improve heat dissipation and reduce electromagnetic interference for multi-drive side-by-side installation |
DIN rail mounting kit is only available for M1 frame. M2 frame does NOT support DIN rail mounting.
- Braking System (Code B = Built-in Brake Chopper)
Recommended Brake Resistor Specifications (Danfoss Official Specification)
Minimum resistance value: 90 Ой
Recommended power rating: ≥200 W (normal start-stop); select 400 W for frequent braking
Danfoss does not provide standard brake resistors with dedicated order numbers. Source externally according to 90 Ой / ≥200 W specification. Increase power rating for heavy-duty cycles.
- ввод в эксплуатацию & Communication Accessories
- PC commissioning cable
FC51 has onboard RS485 terminals. Use USB-to-RS485 adapter together with free MCT10 commissioning software (available for download on official website; Order No.130B1000 refers to software CD media).
- Fieldbus Expansion Note
FC51 has no slots for optional communication cards. Only native Modbus RTU over RS485 is supported; Профибус, EtherNet/IP and other fieldbuses cannot be added.
- Optional Filter & Reactors
This unit is equipped with built-in H3 = Class A1/B RFI filter (Category C1)
No extra input EMC filter required for standard cabinet installation;
For long motor cables or high-interference sites: install external 3-phase input AC line reactor (6 A reactor matched for 2.2 кВт, 400 Система V)
Use shielded motor cables; recommended maximum cable length ≤15 m when built-in filter is enabled.
VII. Запчасти (M2 Frame)
132B0127|FC51 M2 Frame spare parts pack (terminal cover, RS485 connector, earthing screws)
VIII. Matching Drive Motor (Standard Selection)
3-phase asynchronous motor 2.2 кВт, 380 В; rated current ≈4.8~5.2 A, compatible with drive rated output current 5.3 А
- Next-Generation Alternative Inverter (FC51 End-of-Life Backup)
iC2-Micro 2.2 kW 3-phase 400 В. Highly compatible terminal definitions and installation dimensions, applicable as replacement for new projects.
Quick Selection Guidelines
- Single unit on-site commissioning: LCP12 (132B0101) рекомендуется;
- Cabinet door operation required: select 132B0112 (1.5 м) / 132B0102 (3 м);
- Frequent start-stop and rapid braking: externally source 90 Ω ≥200 W brake resistor;
- Multiple drives installed side-by-side: equip M2 de-coupling partition kit 132B0106.
Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи