Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

Delta DVP16SP11T Digital I/O Expansion Module - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

счетчик электроэнергии/электрический/

Delta DVP16SP11T Digital I/O Expansion Module

DVP16SP11T is a 16‑point slim digital mixed I/O expansion module of Delta DVP‑S series, configured as 8 DI (Digital Input) + 8 DO (Digital Output, NPN sinking transistor). It is specially designed for expanding I/O points of Delta DVP‑S series PLC main units, suitable for small automation systems with limited space, and supports high‑speed pulse ...

  • Подробная информация о продукте

DVP16SP11T is a 16‑point slim digital mixed I/O expansion module of Delta DVP‑S series, configured as 8 DI (Digital Input) + 8 DO (Digital Output, NPN sinking transistor).

It is specially designed for expanding I/O points of Delta DVP‑S series PLC main units, suitable for small automation systems with limited space, and supports high‑speed pulse output and counting functions.

  1. Модель Объяснение & Basic Positioning
Part of ModelЗначение
DVPDelta PLC product series code
16Total I/O points: 16 points (8 input + 8 output)
SPMixed I/O type (S = Slim, P = Mixed input/output)
11Version code, standard type
TOutput type: Transistor output (NPN sinking)

Позиционирование продукта:

Compact I/O expansion module for DVP‑S series PLC, used to expand the digital control capability of the main unit.

Especially suitable for space‑limited applications such as small mechanical equipment, автоматизированные производственные линии, and building control systems.

It can be seamlessly connected with DVP‑S series main units (DVP12SA11T, DVP16SA11T, и т. д.).

  1. Ключевые технические параметры
ЭлементСпецификация
Input Characteristics
Input points8 points (DI)
Input typeSinking / sourcing selectable (default sinking)
Rated input voltage24В постоянного тока (±10%)
Input current7mA per point (ON state)
Response time1РС (стандартный), configurable to 0.1ms (high‑speed mode)
Input impedanceПриблизительно. 3.3
Output Characteristics
Output points8 points (DO)
Output typeТранзистор (NPN sinking)
Rated output voltage24В постоянного тока (±10%)
Rated current per point0.5А (continuous), 1А (peak, 0.5с)
Макс. total current4А (all outputs active)
High‑speed pulse output2 points up to 10kHz (specific channels)
Электрический & Physical Characteristics
Power requirement24В постоянного тока, module power consumption approx. 80мА
Insulation resistance≥100MΩ (500В постоянного тока)
Dielectric strength2kV AC (between input/output/power, 1 min)
Рабочая температура0℃ ~ +55℃
Температура хранения-25℃ ~ +70 ℃
Размеры25mm × 76mm × 102mm (slim design, saves cabinet space)
Монтаж35мм стандартный монтаж на DIN-рейку
  1. Функции & Structural Advantages
  2. Ultra‑Slim Compact Design

Only 25mm wide, saves about 50% installation space compared with traditional modules, ideal for high‑density I/O control panels.

Gapless side‑by‑side assembly for maximum space utilization.

Clip‑on connection, no screws required, easy installation.

  1. Flexible I/O Configuration

8 input + 8 output mixed design to meet I/O requirements of most small control systems.

Input supports sinking/sourcing switching, compatible with NPN/PNP sensors.

Fast transistor response (≤10μs), suitable for high‑frequency switching control.

  1. High‑Speed Control Capability

2 high‑speed pulse outputs up to 10kHz for simple positioning (например, stepper motor drive).

4 high‑speed counter inputs up to 20kHz for speed measurement, part counting, и т. д..

Supports interrupt input for fast response to external emergency signals.

  1. Reliable Electrical Performance

Enhanced anti‑interference design, complies with industrial EMC standards (EN 61000‑6‑2 / EN 61000‑6‑4).

Output short‑circuit protection to prevent module damage.

Built‑in surge suppression circuit to protect output devices from back EMF of inductive loads.

  1. Области применения
FieldТипичные примененияПреимущества
Small MachineryPackaging machines, labeling machines, small machine toolsSlim size, high‑speed I/O for precise control
Automated LinesКонвейеры, sorting systems, assembly stationsMixed I/O for various sensors & actuators
Building AutomationLighting control, контроль доступа, HVACLow power, suitable for long‑time operation
Smart AgricultureIrrigation, greenhouse control, feed processingStrong anti‑interference, adapts to harsh environments
New Energy EquipmentSmall PV inverters, системы хранения энергииFast response, supports high‑frequency switching
  1. Comparison of Similar Modules in DVP‑S Series
МодельI/O ConfigurationOutput TypeОсновные характеристикиПриложение
DVP16SP11T8DI + 8DOТранзистор (NPN)16‑point mixed, high‑speed pulse outputFull control of small equipment
DVP16SP11R8DI + 8DORelay16‑point mixed, AC/DC compatibleContactors, solenoids, inductive loads
DVP08SP11T4DI + 4DOТранзистор (NPN)8‑point mixed, smaller sizeMicro‑equipment control
DVP08SP11R4DI + 4DORelay8‑point mixed, economicalSimple control circuits
DVP08SN11T0DI + 8DOТранзистор (NPN)Output only expansionAdditional output points only
DVP08SM11N8DI + 0DODigital InputInput only expansionAdditional input points only
  1. Связь & Примечания по эксплуатации
  2. System Connection

Connect to DVP‑S series main unit via left expansion port; до 8 modules can be expanded.

Modules connected by dedicated expansion cable, no extra configuration needed.

Макс. I/O points after expansion: main unit points + expansion points (max. 128 points).

  1. Wiring Rules

Input wiring: 24VDC supply, COM to 0V, signal terminal to sensor signal.

Output wiring: 24VDC supply, COM to +24V, signal terminal to load negative (sinking output).

4 outputs share one COM terminal; 2 COM groups (4 points each) for grouped control.

  1. High‑Speed Function Configuration

High‑speed pulse output: Y0/Y1 up to 10kHz for stepper or servo motors.

High‑speed counter: X0–X3 up to 20kHz, 1‑phase / 2‑phase configurable.

Configured via programming software (DVPSoft), no extra hardware required.

  1. Меры защиты

Surge suppressor on input side to resist external interference.

Freewheeling diode for inductive loads to protect transistors.

Avoid output short‑circuit; max. 0.5A continuous per output.

  1. Выбор & Замена
  2. Selection Guidelines

Output type: Transistor for high‑frequency, low inductance; Relay for AC/DC, high power.

I/O points: Choose 8‑point or 16‑point based on controlled devices.

Space: Slim modules preferred for narrow control cabinets.

High‑speed functions: Select T‑type for pulse output or high‑speed counting.

  1. Replacement Options
RequirementRecommended ReplacementAdvantage
Relay output neededDVP16SP11RAC/DC load compatible, long contact life
Fewer I/O pointsDVP08SP11TSmaller size, lower cost
Higher pulse frequencyBuilt‑in high‑speed channels of DVP‑S main unit (up to 100kHz)Higher precision positioning
Cross‑series replacementDVP‑ES2 series expansion (DVP08SP11T‑ES2)Compatible with DVP‑ES2, richer functions
  1. Типичные примеры применения
  2. Small Packaging Machine:

8 inputs (material position, product detection, safety door),

8 outputs (feeding motor, sealer, cutter, conveyor),

high‑speed pulse for feeding positioning.

  1. Automated Assembly Line:

Inputs (part position, fixture status),

Outputs (cylinders, motors, indicators),

high‑speed counting for production statistics.

  1. Building Lighting Control:

Inputs (motion sensor, light sensor, manual switch),

Outputs (цепи освещения, HVAC fans),

energy‑saving control.

Packing Specification: 1 pc/box, 10 pcs/carton

Основные различия: Delta DVP16SP11T vs. Similar Modules

At a Glance:

Delta DVP16SP11T features ultra‑slim 25mm width, экономически эффективный, seamless compatibility with DVP‑S series.

Сименс / Mitsubishi / Omron excel in industrial ecosystem and high‑end functions.

Xinje focuses on cost‑effective domestic replacement.

  1. Main Competitors & Basic Comparison
ЭлементDelta DVP16SP11TSiemens S7‑200 SMART EM AT02Mitsubishi FX5U‑16EYT/ESOmron CP1W‑16ETXinje XC3‑16EYT
PositioningDVP‑S slim mixed I/OS7‑200 SMART compact expansionFX5U/iQ‑F high‑performanceCP1H/CP1L general expansionXC3 domestic compact
I/O Config8DI + 8DO16DI + 16DO16DI + 16DO16DI + 16DO16DI + 16DO
OutputTransistor NPN sinkingТранзистор (sink/source selectable)Транзистор (sink/source selectable)Транзистор (sink/source selectable)Transistor sinking
Input Voltage24В постоянного тока (±10%)24В постоянного тока24В постоянного тока24В постоянного тока24В постоянного тока
Ширина25мм (thinnest)приблизительно. 30ммприблизительно. 28ммприблизительно. 27ммприблизительно. 26мм
Compatible CPUDVP‑S series onlyS7‑200 SMART onlyFX5U / FX3U seriesCP1H / CP1L / CP1EXC3 / XC2 series only
Макс. РасширениеДо 8 modulesДо 8 modulesДо 16 modulesДо 8 modulesДо 7 modules
Package1 pc/box, 10 pcs/carton1 pc/box1 pc/box1 pc/box1 pc/box
  1. Key Functional & Performance Differences

2.1 High‑Speed Control (Основное отличие)

ЭлементDelta DVP16SP11TSiemens EM AT02Mitsubishi FX5U‑16EYTOmron CP1W‑16ETXinje XC3‑16EYT
Pulse Output2 points @10kHz2 points @≈2kHz4 axes @200kHz (built‑in)4 points @100kHz2 points @10kHz
High‑Speed Counter4 points @20kHz6 points @100kHz6 points @200kHz4 points @200kHz4 points @10kHz
Input Response0.1РС (high‑speed)1РС0.2РС0.1РС0.5РС
StrengthBasic high‑speed, small positioningStable, low‑speed logicUltra‑high frequency, precision positioningStrong counting, high anti‑interferenceLowest cost, basic control

2.2 Установка & Электропроводка

ЭлементDelta DVP16SP11TSiemens EM AT02Mitsubishi FX5U‑16EYTOmron CP1W‑16ETXinje XC3‑16EYT
МонтажClip‑on DIN rail, gaplessScrew + DIN-рейкаTerminal block, plug‑inDIN-рейка + screwClip‑on DIN rail
ТерминалSpring clamp, tool‑freeВинтовой терминалSpring clampВинтовой терминалSpring clamp
SpaceUltra‑compactStandard compactStandard compactStandard compactStandard compact

2.3 Software & Коммуникация

ЭлементDelta DVP16SP11TSiemens EM AT02Mitsubishi FX5U‑16EYTOmron CP1W‑16ETXinje XC3‑16EYT
SoftwareDVPSoft (easy to use)TIA Portal (powerful)GX Works3 (FX compatible)CX‑Programmer (stable)XCPPro (user‑friendly)
КоммуникацияMODBUS RTU/TCP, CANopenПРОФИНЕТ, MODBUS TCPCC‑Link, Ethernet/IP, MODBUSMODBUS RTU/TCP, HostLinkMODBUS RTU/TCP
EcosystemSeamless with Delta servo/HMIFull Siemens integrationPerfect with Mitsubishi servo/inverterHigh compatibility with Omron devicesGood with domestic equipment
DiagnosisBasicComprehensiveDetailed, remote monitoringPrecise, fast fault locationBasic
  1. Application‑Based Selection Suggestions
  2. Best for Delta DVP16SP11T

Extremely limited space: 25mm ultra‑slim for compact panels.

DVP‑S series system: Direct expansion without adaptation.

Cost‑effective + basic high‑speed: 10kHz pulse / 20kHz counter for small packaging, labeling, конвейеры.

Fast delivery: DVPSoft is easy to learn, short commissioning time for OEMs.

  1. Best for Siemens S7‑200 SMART EM AT02

Large/complex lines: ПРОФИНЕТ, full diagnosis, multi‑device coordination.

Siemens ecosystem: ПЛК, servo, HMI unified.

Высокая надежность: Automotive, chemical, water treatment.

  1. Best for Mitsubishi FX5U‑16EYT/ES

Precision positioning: 200kHz pulse, multi‑axis interpolation for CNC, precision assembly.

Mid‑to‑high automation: Built‑in Ethernet, analog, CC‑Link.

Long‑term support: Mature FX ecosystem.

  1. Best for Omron CP1W‑16ET

Суровые условия: Strong anti‑interference, dust, electromagnetic noise.

Counting & inspection: High‑speed counting for packaging, sorting.

Omron sensor/HMI system.

  1. Best for Xinje XC3‑16EYT

Domestic replacement / tight budget: Lower cost than Delta.

Beginner development: XCPPro easy to use.

Domestic equipment matching: High cost‑performance.

  1. Cross‑Brand Replacement Notes
  2. I/O point match: Delta is 8DI+8DO; Siemens/Mitsubishi/Omron are 16DI+16DO per module. Adjust I/O layout.
  3. Output polarity: Delta is NPN sinking; others often support sink/source. Confirm COM wiring.
  4. High‑speed downgrade: If replacing from Mitsubishi/Siemens to Delta, reduce pulse/counter speed and reprogram.
  5. Коммуникация: Delta uses mainly MODBUS; Siemens/Mitsubishi support industrial Ethernet. Adjust protocol settings.

Предыдущий:

Оставить ответ

Оставить сообщение