Fluke 376-FC AC/DC Clamp Meter

FC Meaning: Fluke-Connect, Bluetooth wireless connection, supporting mobile APP data logging, trend graphing and on-site report generation. Part of the 370-FC series industrial-grade clamp meters. Supplied standard with an 18-inch iFlex flexible current probe (optional for 375-FC). Core Specifications Item Specifications Jaw AC/DC Current 0‑1000A (True‑RMS) iFlex Flexible Probe AC Current 0‑2500A AC AC/DC Voltage ...

  • Подробная информация о продукте

FC Meaning: счастливая случайность-Соединять, Bluetooth wireless connection, supporting mobile APP data logging, trend graphing and on-site report generation.

Part of the 370-FC series industrial-grade clamp meters. Supplied standard with an 18-inch iFlex flexible current probe (optional for 375-FC).

Основные характеристики

ЭлементТехнические характеристики
Jaw AC/DC Current0‑1000A (True‑RMS)
iFlex Flexible Probe AC Current0‑2500A AC
Напряжение переменного/постоянного тока0‑1000V AC/DC
Частота5‑500Hz (for both meter jaw and iFlex)
Сопротивление0‑60kΩ with continuity test
Емкость0‑1000μF
DC Millivolts500mV range
Jaw Opening34 мм
Рейтинг безопасностиCAT‑III 1000V / CAT‑IV 600V
Источник питания4 × AA batteries
Гарантия3‑year

Ключевые особенности

  1. VFD Low-pass Filter: Optimized for VFD output measurements, suppresses carrier-frequency interference for accurate motor-drive readings; not available on 374-FC.
  2. In-Rush Surge / Starting Current Mode: Filters noise to accurately capture motor inrush current, matching real-world conditions seen by protective devices.
  3. Fluke-Connect Bluetooth Wireless: Remote readings via mobile device, регистрация данных, trend curves, on-site PDF report generation; ShareLive video call for collaborative troubleshooting, keeping users away from arc-flash hazards.
  4. Мин / Макс / Average recording: Captures intermittent fault fluctuations.
  5. iFlex Flexible Coil: Enables measurements in confined spaces and on large-diameter cables without cable disconnection.

Стандартный упаковочный лист

376-FC clamp meter main unit

i2500-18 iFlex flexible current probe (18-дюйм)

Test leads and test probes

TPAK magnetic hanging strap

Мягкий чехол для переноски

User manual and safety manual

Сравнение серий (374-ФК / 375-ФК / 376-ФК)

МодельJaw AC/DC CurrentiFlex IncludedVFD FilterDC‑mV
374‑FC600А❌ Optional
375‑FC600А❌ Optional
376‑FC1000А✅ Standard

Совет по выбору: Choose 376-FC for 1000A AC/DC, frequent VFD testing, high-current work and wireless logging. Choose 375-FC for applications within 600A.

Типичные применения

Industrial motors, variable-frequency drives, distribution panels, UPS, Фотоэлектрические инверторы

Plant electrical maintenance, equipment commissioning, диагностика неисправностей, motor inrush-current testing

On-site remote reading, data archiving and test-report generation

Использование & Примечания по техническому обслуживанию

  1. The iFlex flexible coil measures AC only, DC measurements must use the meter’s physical jaws.
  2. Enabling the VFD filter reduces bandwidth; disable it for standard power-frequency measurements.
  3. In-Rush mode captures transient startup events and shall not be used for steady-state readings.
  4. Second-hand inspection checklist: Undamaged jaws, intact iFlex coil, functional Bluetooth, sound lead insulation, valid calibration status.

Fluke 375-FC vs 376-FC Key Differences

Both support Fluke-Connect Bluetooth, VFD filter, In-Rush mode, DC-mV and True-RMS, with identical safety ratings. Differences lie in jaw current range, iFlex inclusion and crest factor.

Элемент сравненияFluke 375‑FCFluke 376‑FC
Jaw AC/DC Current600A AC/DC1000А (999.9А) переменный/постоянный ток
iFlex Flexible ProbeНеобязательный, max 2500A ACStandard i2500‑18 (18‑inch), max 2500A AC
Диапазон напряжения1000В переменного/постоянного тока1000В переменного/постоянного тока
VFD Filter✅ Поддерживается✅ Поддерживается
In‑Rush Motor Surge✅ Поддерживается✅ Поддерживается
DC‑mV 500mV✅ Поддерживается✅ Поддерживается
Bluetooth FC Wireless✅ Поддерживается✅ Поддерживается
Crest Factor (CF)3 @ 600A3 @ 500A; 2.5 @ 1000A, better distorted‑current performance at high current
Jaw Opening34 мм34 мм
Гарантия3‑year3‑year

Plain-language Explanation

  1. 375-ФК: 600A upper limit

Suitable for most low-voltage distribution panels, motors and loads up to 400A. iFlex coil is sold separately. Cost-effective for routine plant maintenance where 600A is sufficient.

  1. 376-ФК: 1000A jaw + factory-fitted iFlex

Designed for 800-1000A loads, шины, high-power UPS and high-power VFDs. Ready-to-measure up to 2500A AC out-of-box with no extra probe purchase.

⚠️ Note: iFlex flexible coil measures AC only. High DC current must be measured by the meter’s built-in jaws.

Руководство по выбору

Most operating conditions ≤600A, rare high-AC-current work → 375-FC

Frequent 800-1000A measurements, regular large-AC-current testing, no wish to buy iFlex separately → 376-FC

Second-hand Purchase Notes

Many used 375-FC units do not include iFlex. Genuine complete 376-FC units come with the i2500-18 flexible coil.

For both models verify: VFD filter function, In-Rush mode, Bluetooth connectivity, jaw movement and lead insulation integrity.

Различия в приложениях: Fluke 375-FC vs 376-FC

Feature sets are nearly identical: VFD filter, In-Rush surge, Fluke-Connect Bluetooth and DC-mV are all present. Application gaps stem from two core points:

① Maximum jaw current: 600A AC/DC for 375-FC; 1000A AC/DC for 376-FC

② iFlex is factory-supplied on 376-FC but must be purchased separately for 375-FC.

🟢 375-FC Application Scope (600A jaw, iFlex optional)

For general-purpose plant maintenance with steady-state load current ≤600A and rare >600A DC measurements.

  1. Medium-small VFD-driven motors: 30-200 kW motors, MCC cabinets; measure operating current, startup inrush and VFD output (VFD filter enabled).
  2. General low-voltage distribution panels: Feeder circuits, ≤400A molded-case breaker loops; routine inspection and preventive maintenance with data logging.
  3. DC-side work: DC power panels, small-capacity UPS and DC busbars, for DC currents no higher than 600A.
  4. Коммерческие здания, HVAC and general equipment commissioning: iFlex probe may be purchased later if occasional high-AC-current measurement is needed.
  5. Maintenance teams: Majority circuits sit below 600A; cost-optimized choice when iFlex is not used daily.

⚠️ 375-FC Limitations

Jaw DC measurement is capped at 600A. DC above this value cannot be measured (iFlex works for AC only).

Flexible coil is not supplied; extra procurement required for large cables or tight-fit busbar measurements.

🔴 376-FC Application Scope (1000A jaw, iFlex standard)

Targets high-current scenarios, frequent 600-1000A AC/DC measurements and regular flexible-probe usage for large cables / шины.

  1. Heavy-duty industrial motors: 200-450 kW motors with operating current at or above 600A; motor inrush testing and high-power VFD circuit diagnostics.
  2. High-power UPS, low-voltage busbars and incoming cabinets: Transformer secondary and 800-1000A incoming-feed circuits; direct high-DC-current readings via main jaws.
  3. PV and energy-storage PCS converters: Mixed AC-DC environments; capable of near-1000A DC readings which cannot be achieved by the 375-FC.
  4. Frequent iFlex-probe deployments: Congested cable trays, busbars and oversized cables that cannot fit within standard jaws; 2500A-AC measurement capability available immediately out-of-box.
  5. System integration, project commissioning & EPC sites: Mixed-spec loads covering low-ampere loops through kilo-ampere incoming feeds; one-meter coverage; remote readings for test-reporting and arc-flash hazard mitigation.

⚠️ 376-FC Caveat

iFlex remains AC-only; 1000A DC is measured exclusively through the physical meter jaws.

Справочник по быстрому выбору

Working ConditionПредпочтительная модель
Most circuits ≤600A, seldom encounter high‑current loads, infrequent iFlex use375‑FC
Regular >600A AC/DC loads (incoming cabinets, high‑power PCS, большие моторы)376‑FC
Frequent large‑cable / busbar work, want iFlex included as standard376‑FC
DC current routinely exceeds 600A (energy‑storage, heavy‑duty DC busbars)376‑FC only (iFlex cannot measure DC)
Budget‑constrained, iFlex can be procured later on demand375‑FC

Common Field Pitfall Reminder

The iFlex flexible probe measures AC only.

👉 High DC current must always use the meter’s hard jaws regardless of model; flexible coils offer no DC capability.

Therefore for energy-storage / PCS DC-side currents above 600A, the 375-FC will overflow; 376-FC is mandatory.