Позиционирование: 23.1-inch IMO-compliant marine radar dedicated display unit (CR = Radar version). It is the matching display for FAR-28X7 radar and is now End of Life (окончание срока действия).
Различие: MU-231 is a universal multi-input marine display; MU-231CR is a radar-customized version with interfaces and firmware specially adapted for FURUNO black-box radar systems. It is NOT a general-purpose monitor.
Ключевые характеристики
Экран: 23.1″ цветной ЖК-дисплей, UXGA 1600 × 1200
Яркость: 400 кд/м², built-in light sensor for automatic dimming
Contrast Ratio: 600:1
Входной сигнал: Single dedicated DVI-D radar port, no RGB / composite video input, PIP (Picture-in-Picture) не поддерживается (main difference from MU-231)
Источник питания: 100–230 VAC, single-phase 50/60Hz (только переменный ток)
Сертификация: IMO Wheel Mark, compliant with marine radar regulations for seagoing vessels
Power-on Logic: Auto power on/off triggered by DVI signal; no physical control buttons on the unit itself
Монтаж: Монтаж заподлицо с панелью / cantilever bracket mount (bracket sold separately)
Масса: 16.6 кг (крепление на панели); 23.5 кг (bracket mount)
Compatible Radar Systems
✅ FAR-2807 / FAR-2817 / FAR-2827 (FAR-28X7 series, paired with RPU-013 radar processor)
✅ FAR-2107, FAR-2127 (black-box radar with dedicated DVI-D radar video output)
⚠️ Важное ограничение: Cannot connect directly to standard PC DVI outputs. It only recognizes proprietary radar DVI video signals from FURUNO radar processors.
System Components for Complete FAR28X7 Radar
MU-231CR: Radar display unit
RPU-013: Radar processor unit
RCU-014: Full keyboard control unit / RCU-015: Trackball control unit / RCU-016: Remote control unit
XN-12AF / XN-20AF / XN-24AF: Radar antenna units
Замена & Информация о запасных частях
- Original new units are no longer available on the market; supplies are mainly used pull-outs and refurbished units.
- Варианты замены: New-generation FURUNO radar displays (processor protocol and panel cutout dimensions must be evaluated together).
- Общие точки отказа: Backlight board, DVI interface board, power supply board, ambient light sensor assembly.
- Document Part Number: OMC-44690 (shares base manual with MU-231; separate schematic drawings apply for CR variant).
Сравнительная таблица: MU-231CR vs MU-231
| Элемент | MU-231CR (Radar Version) | MU-231 (Universal Marine Version) |
| Вход | Dedicated radar-only DVI-D port only | Dual DVI + RGB + composite video |
| PIP Picture-in-Picture | ❌ Не поддерживается | ✅ Поддерживается |
| Приложение | Exclusive for FAR-series radar | Radar, ECDIS, echo sounder, sonar, camera multi-source switching |
| Auto Power Control | DVI signal triggered | DVI signal triggered |
FURUNO MU-231CR Supporting Manual List
Важное примечание: FURUNO does not release a standalone manual for MU-231CR. The MU-231CR is a dedicated display bundled with FAR-28X7 radar systems. The base hardware documentation is shared with MU-231. CR-specific differences, radar linkage logic and proprietary DVI protocol details are documented within the FAR-28X7 radar system manuals.
- Main Display Operation Manual (Обязательный, OMC-44690)
Title: MU-231 Operator’s Manual
Document No.: OMC-44690, Revision D2 (latest revision)
Содержание: Installation cutout dimensions, проводка, источник питания, auto brightness adjustment, menu configuration, basic maintenance, outline drawings, определения терминала, basic troubleshooting
Применимый: MU-231 / MU-231CR (CR variant only differs in firmware and input lockout; механический, power and hardware circuits are identical)
Язык: Bilingual English + японский
Ограничение: This manual does not cover proprietary radar DVI protocol or RPU-013 interworking logic, only the display hardware itself.
- Quick Reference Guide (for on-site commissioning)
Title: MU-190 / MU-231 Operator’s Guide
Compact quick-start booklet for vessel crews and field technicians: brightness adjustment, auto dimming, access to installation menu, menu unlock
No schematics or spare part BOM; for daily onboard operation only.
- Radar System Master Manual (Core Reference for MU-231CR, Highly Recommended)
The MU-231CR cannot operate independently without the FAR-28X7 radar processor. Radar linkage, signal timing, power-up sequence and RCU control integration are all covered in this set of documents
- FAR-2807 / FAR-2817 / FAR-2827 Operator’s Manual (Radar Operation Manual)
For RPU-013 processor, covers radar video output to MU-231CR, trackball/keyboard control, ARPA target tracking
- FAR-28X7 Installation & Service Manual
Contains complete system interconnection wiring diagrams, RPU-013 ↔ MU-231CR dedicated DVI link description, локализация отказов, spare parts list and system commissioning procedures
- Supplementary control unit manuals: RCU-014 / RCU-015 / RCU-016 Operator Manuals
- Service-Level Manuals (Ремонт на уровне платы, for agents & service workshops)
MU-231 Service Manual: Schematics, плата питания / backlight board / driver board disassembly, voltage test points, spare part BOM
⚠️ This document is not available for public download; access restricted to FURUNO authorized service channels, public resources are scarce.
- Multilingual Versions (Необязательный)
MU-190/MU-231 French Quick Guide, Spanish Quick Guide (for foreign vessel crews)
Reading Priority Recommendation
✅ On-site installation & проводка: OMC-44690 (MU-231 Operator Manual) + FAR-28X7 Installation Manual
✅ Daily radar operation by crew: FAR-28X7 Radar Operator Manual (Do not rely only on the display manual; the CR model has no independent radar picture menus)
✅ Board replacement & черный экран / no radar signal troubleshooting: FAR-28X7 Service Manual + MU-231 Service Manual
Common Pitfall Reminders
- Do not commission MU-231CR using only the MU-231 universal manual: universal MU-231 supports multi-DVI and PIP, while MU-231CR firmware disables these functions. CR-specific notes inside the FAR radar manual must be referenced.
- Searching “MU-231CR manual” online will almost never return standalone documents. Industry standard practice: use OMC-44690 together with FAR28X7 system manuals.
FURUNO MU-231CR Black Screen / No Radar Image Troubleshooting Checklist
Предварительное условие: MU-231CR is a dedicated radar display and only accepts proprietary DVI signals from RPU-013 radar processors. Troubleshooting logic differs from standard monitors. Three symptom categories: [Complete black screen, индикатор питания выключен], [Power indicator ON but screen black / backlight on, no radar picture], [Backlight ON, черный экран, No Signal prompt]
- Initial Status Verification (Onboard Priority Checks)
- Verify power supply for the whole system: MU-231CR runs on AC 100–230V. Check circuit breakers, internal fuses, shipboard voltage, потеря фазы, voltage drop and transient power loss.
- Confirm matched equipment: This display must work with RPU-013 radar processor. Antenna unit and RCU control unit also need power supply.
- Observe front indicator lamp:
Power lamp OFF: Fault in power circuit or display power supply board
Power lamp steady ON, no picture: Fault in signal link, RPU processor, dedicated DVI cable or backlight/driver board
- Follow regulated power-up sequence: Power on RPU-013 radar processor first, then MU-231CR. MU-231CR wakes up only upon valid radar DVI signal; standalone power-up will result in black screen (not a hardware fault).
Распространенное заблуждение: Powering MU-231CR alone without RPU signal output → black screen, this is normal behaviour.
- Symptom A: Fully Black Screen, Power Indicator OFF
- Measure AC input voltage at the socket to confirm within rated range.
- Check internal input fuse on display power board. Replace with same specification if blown. Never use a higher-rated fuse.
- Disconnect DVI cable and power the display separately to check whether downstream short circuit pulls down power rail.
- If input voltage is normal and fuse intact but lamp remains off: fault points to MU-231CR power supply board.
- Measure power board output rails against service manual: 24В, 5V and backlight supply.
- Symptom B: Power Lamp ON, No Backlight (Screen Completely Dark)
- Open cover slightly and listen for faint high-frequency hum from backlight inverter; no hum = backlight circuit failure.
- Troubleshoot: backlight inverter / backlight panel, backlight power harness, loose LVDS screen cable.
- Distinguish LCD panel damage vs backlight driver failure.
- Quick test: Shine a flashlight obliquely onto the screen. Faint radar menu characters visible → backlight failure; nothing visible → signal / неисправность материнской платы.
- Symptom C: Backlight ON, Black Screen, “No Signal” Prompt (Самый распространенный)
Критический: MU-231CR runs dedicated firmware, standard PC DVI signals are rejected and trigger No Signal.
- Check RPU-013 radar processor status: Power and RUN indicators, active fault codes.
- Reboot sequence: Full power cut for 3 минуты (разряд конденсатора) → power RPU-013, wait 2–3 minutes for full self-test completion → then power MU-231CR.
- Inspect dedicated DVI cable: This is FURUNO radar-specific DVI cable; standard DVI cables are not compatible. Бент, oxidized or loose pins at connectors are frequent failure points.
- Re-seat DVI connectors at both ends: RPU-013 rear DVI port ↔ MU-231CR DVI input port, clean pin contacts.
- Cross-test if spare parts available:
Swap with a confirmed good original radar DVI cable
Если возможно, connect MU-231CR to a known working RPU-013 from another FAR-28X7 system to isolate failure between display and processor
- Inspect RPU-013 internals: RPU mainboard, video output board; faulty RPU will not transmit proprietary radar DVI stream.
- Примечание: Faulty RCU control box will not cause black screen / no image, only loss of radar control.
- Symptom D: Backlight ON, Screen Black, No “No Signal” Pop-up
- Loose LVDS/eDP screen cable: Power off and re-seat harness between screen driver board and LCD panel.
- Display main signal board failure: Receives DVI clock but cannot decode FURUNO proprietary radar video.
- Повреждение прошивки: CR firmware is locked in radar-only mode. Corrupted firmware can only be reflashed by FURUNO service; field reflashing is not possible.
- Относящийся к окружающей среде & Interference Checks (Often Overlooked Onboard)
- Ship power harmonic distortion / inverter noise: If radar shares supply with heavy loads (краны, большие моторы), temporarily connect to isolated clean power supply for testing.
- Заземление: RPU, display and antenna protective earth must connect reliably to ship ground. Poor grounding causes intermittent video dropout and black screen.
- Температура: Overheat inside cabinet triggers thermal protection on power board and DVI chipset; function resumes after cooling. Recurring issue indicates poor ventilation.
- Isolation Logic for Rapid Fault Localization
Normal power + RPU self-test OK + good dedicated DVI cable → Fault inside MU-231CR (плата питания / backlight board / main control board / LCD panel)
Normal power + replacement good MU-231CR still shows no signal → Fault in RPU-013 radar processor or antenna link
Intermittent black screen, recovered after tapping connector → DVI cable or contact pin failure
- Repair Prohibitions & Примечания по безопасности
- Never substitute MU-231CR with a standard commercial DVI monitor; protocol incompatibility means no radar picture.
- Do not flash universal MU-231 firmware onto MU-231CR; radar-specific functions will be lost and the unit bricked.
- Always cut power before opening enclosure; power board capacitors hold high residual voltage, allow sufficient discharge time.
- Закупка запасных частей: Complete pull-out kits (RPU + DVI cable + MU-231CR) являются предпочтительными; individual boards are scarce in supply.
- Post-repair commissioning: Re-integrate with FAR-28X7 radar; verify radar range scales and ARPA output parameters.
- Quick Fault Reference Table
| Симптом | Highest Probable Failure Point |
| Lamp off, no unit response | Input power supply, internal fuse, power supply board |
| Lamp on, faint menu visible with flashlight | Backlight panel / backlight inverter |
| Lamp on, backlight on, No Signal message | RPU not ready, dedicated DVI cable damaged, RPU video output board |
| Intermittent black screen, recovers with vibration | DVI connector or loose screen cable |
| Black screen when cold, works after warming up | Ageing electrolytic capacitors on power board |
FURUNO MU-231CR Supporting Equipment Status Check (RPU-013, XN-12AF/20AF/24AF Antenna, RCU-014/015/016)
Системная цепочка: Antenna Unit → RPU-013 Radar Processor → Dedicated DVI Cable → MU-231CR. RCU is only for control and does not generate radar video.
Основной принцип: MU-231CR itself does not generate radar signals. Radar image presence ultimately depends on whether RPU-013 outputs valid proprietary radar DVI video stream.
- RPU-013 Radar Processor (Высший приоритет)
1.1 Front Panel Indicator Interpretation
POWER LED: Steady green = Input power normal; OFF → Check RPU supply, internal fuse and power module.
Светодиод РАБОТЫ: Steady green after self-test completion = Normal operation;
Мигает: Self-test in progress, firmware loading or active fault alarm
Red steady / мигающий: Неисправность, прочитать код неисправности
ALARM LED: Red illuminated = active fault (antenna communication, transceiver, перегрев, video output, вентилятор, ADC fault etc.)
✅ Normal healthy state: POWER steady green + RUN steady green + ALARM off. Allow 2–3 minutes post power-up for self-test before radar DVI output activates.
1.2 Two Methods to Retrieve RPU Fault Codes
- Метод А (MU-231CR can display, only missing radar echo): Enter radar menu →【Alarm / Fault Log】to review fault history
- Метод Б (MU-231CR no signal / черный экран): Read 7-segment display or status LEDs on RPU mainboard, cross-reference FAR-28X7 service manual for fault definitions
Common alarm categories: antenna communication error, transceiver fault, перегрев, отказ вентилятора, DVI video output fault, ADC fault.
1.3 Verify RPU DVI Radar Output (Field Test)
Примечание: Standard PC DVI monitor cannot decode this proprietary signal.
Состояние 1: Confirmed good MU-231CR spare unit: swap in spare display. If spare shows radar picture → original MU-231CR faulty; spare still No Signal → RPU no video output.
Состояние 2: осциллограф (professional service): Measure DVI differential clock and data waveform at RPU port. Clock present but no valid image data → RPU internal video board failure.
Состояние 3: RPU internal fan observation: Fan should rotate smoothly after power-up. Stopped fan triggers over-temperature protection and cuts video output.
1.4 RPU Power Supply Check
RPU supply is typically AC100–230V. Измерьте напряжение на клеммах, check loose terminals, voltage drop and ship power harmonic noise.
RPU has separate internal fuse. Never short-circuit blown fuse; investigate downstream short circuit (antenna coaxial cable or transceiver assembly).
- XN-12AF / XN-20AF / XN-24AF Antenna Unit (Antenna + Transceiver)
Antenna faults fall into two categories: Antenna not rotating, Antenna rotates but no echo / потеря связи
2.1 Mechanical Rotation Check
After RPU self-test completes, antenna should rotate at constant smooth speed (nominal ~24 rpm).
No rotation at all: Motor power supply, slip ring, drive circuit or RPU antenna communication fault.
Sticking, аномальный шум, intermittent rotation: Bearing seizure, slip ring oxidation and wear, motor failure.
⚠️ Предупреждение о безопасности: Rotating radar antenna presents mechanical hazard; do not approach. X-band radar transmits RF energy; avoid standing close and facing antenna front during transmission.
2.2 Коммуникация & RF Status
Antenna to RPU link: RF coaxial cable + multi-core control cable (slip ring harness).
RPU reports【Antenna Comm Error】: Control wire, slip ring and connector oxidation / open circuit are top causes.
Antenna rotates but no echo: Magnetron, transceiver module or modulator failure; magnetron degradation is a common consumable failure.
Basic judgement: Smooth rotation + no antenna communication alarm on RPU ≠ RF transmission is healthy. Communication link OK only; RF output power needs verification with RF power meter.
2.3 Antenna Temperature & Waterproof Inspection
Water ingress and condensation inside antenna housing cause RF short and slip ring corrosion. Check drain holes are clear. High internal temperature triggers antenna over-temperature protection and RPU transmission shutdown.
- RCU Control Unit: RCU-014 / RCU-015 / RCU-016 (Клавиатура / Trackball)
Критический: RCU failure will NOT cause black screen or missing radar image!
RCU is human-machine interface only, communicating with RPU over RS485 / proprietary serial bus. It does not carry radar video.
✅ Normal status indicators:
- RCU power indicator illuminates
- When MU-231CR displays radar picture, keys and trackball operate radar menu, change range scale and adjust gain.
❌ Fault symptoms: Picture normal, but keys unresponsive, trackball drift, menu cannot be controlled.
Поиск неисправностей: RCU power, serial communication cable, termination resistor, address setting. Multiple parallel RCU units with conflicting addresses will cause loss of control.
- Cable Link Inspection (Frequently Overlooked)
- RPU ↔ MU-231CR dedicated DVI cable: FURUNO custom radar cable; pin definition and timing differ from standard DVI. Visual check for bent pins, oxidation and jacket damage. Vibration test to reproduce intermittent dropout.
- RPU ↔ Antenna: Кабель управления + RF coaxial: Water ingress and poor contact at coaxial connectors cause echo loss and antenna alarms. Perform VSWR standing wave ratio test; excessive VSWR indicates RF link fault.
- RPU ↔ RCU communication cable: Экранированная витая пара, экран заземлен с одного конца; incorrect grounding causes unstable communication.
- Standard Fast Diagnostic Workflow (Field Engineer Sequence)
- Full power cut for all equipment, rest 3 minutes for capacitor discharge.
- Power sequence: Antenna unit → RPU-013. Wait 2–3 minutes for self-test completion, confirm RUN steady green, ALARM off and antenna starts rotation.
- Power MU-231CR and observe screen behaviour.
- Cross-test with spare MU-231CR to separate faults between【RPU no video output】and【display hardware failure】.
- If RPU persistently raises antenna alarm: Inspect antenna control wiring, slip ring and coaxial cable, antenna motor.
- Radar picture present but no control: Troubleshoot RCU communication circuit separately.
- Key Summary Table
| Компонент | Failure can cause black screen / no radar image | Typical Healthy Status |
| RPU-013 | ✅ Да (Highest frequency) | POWER green, RUN steady green, ALARM off, fan running, proprietary radar DVI output active |
| XN Antenna Unit | ✅ Да (No echo, RPU alarm may cut video) | Smooth constant rotation, no antenna communication alarm on RPU |
| Dedicated DVI Cable | ✅ Да | Connector intact, no bent pins, picture restored after swapping known good cable |
| RCU Control Unit | ❌ Нет | Indicator lit; keys and trackball operate radar menu when picture is present |
- Supplementary Reminders
- Do not measure DVI differential signals with a multimeter; risk of burning driver chip. Cross-replacement test is preferred for qualitative diagnosis.
- Many RPU faults are intermittent: works cold, drops signal under navigation vibration. Focus inspection on slip ring, coaxial connectors and DVI interfaces.
- RF power and VSWR are metrology-grade tests requiring marine RF power meter / SWR bridge; standard multimeter cannot verify RF performance.
FURUNO MU Series Marine Radar Dedicated Display Unit List
Key Classification Rule:
MU-xxxCR = Radar-locked dedicated version (only accepts proprietary DVI signals from matched black-box radar RPU, no PIP, incompatible with standard PC / ECDIS multi-source inputs)
MU-xxx (without CR suffix) = Universal marine display, supports radar, ECDIS, echo sounder, camera inputs and PIP picture-in-picture
All models carry IMO Wheel Mark certification, designed for FAR-28X7 / FAR-21X7 / FAR-15X3 black-box radar systems. CR variants are factory-bundled with radar sets and not sold as standalone original spare units, circulated in used/refurbished spare markets.
Integrated radar (FR series, FAR all-in-one units with built-in screen) are excluded; these are not independent MU display units.
- Radar-Locked Dedicated CR Models (Primary Category for Your Application)
| Модель | Размер экрана | Разрешение | Matched Radar Processor | Примечания | Статус жизненного цикла |
| MU-231CR | 23.1″ | UXGA 1600×1200 | RPU-013 (FAR-2807/2817/2827, FAR-2107/2127) | Single dedicated radar DVI only, no PIP, no composite / RGB input, auto light sensor | окончание срока действия, used/refurbished spare only |
| MU-201CR | 20.1″ | SXGA 1280×1024 | RPU-011 / Early FAR21XX black-box radar | Older 20-inch radar dedicated display, proprietary DVI interface | окончание срока действия, very limited stock |
| MU-190CR | 19″ | SXGA 1280×1024 | RPU-024 / FAR-1513-BB / FAR-1523-BB | 19-inch radar dedicated variant, multi-input locked by firmware | окончание срока действия, common on fishing / inland vessels |
| MU-170CR | 17″ | SXGA 1280×1024 | Early low-power black-box radar | Older 17-inch model, extremely scarce supply | окончание срока действия |
| MU-151CR | 15″ | XGA 1024×768 | Small fishing vessel black-box radar | Early compact radar dedicated display | окончание срока действия |
Добавка: CR variants share identical mainboard hardware with same-number universal MU models. Difference is firmware input lock and proprietary protocol validation, only accepting matched RPU radar stream. Firmware cross-flash is prohibited and will brick the unit.
- Universal Marine Displays (MU non-CR suffix, compatible with radar, ECDIS etc.)
Universal models: Dual DVI, RGB, CVBS composite video, PIP, multi-source switching. Can connect to same RPU radar (but not recommended as direct drop-in replacement for CR on original FAR28X7 radar; timing and ARPA compatibility issues may arise).
| MU-152 | 15″ | XGA 1024×768 | AC100–230V | FR-CAR1/2, FAR-1513-BB, FAR-1523-BB | Активные продажи |
| MU-152HD | 15″ | XGA 1024×768 | переменный/постоянный ток | High brightness sunlight-readable, fishing vessel black-box radar | Активные продажи |
| MU-190 | 19″ | SXGA 1280×1024 | AC100–230V | FAR-1513/1523, FAR-2258, FR-CAR | окончание срока действия, большая установленная база |
| MU-190HD | 19″ | SXGA 1280×1024 | переменный/постоянный ток | High brightness, flybridge open-air installation | Активные продажи |
| MU-192 | 19″ | SXGA 1280×1024 | AC100–230V | Successor replacing MU-190, IMO certified | Активные продажи |
| MU-192HD | 19″ | SXGA 1280×1024 | переменный/постоянный ток | Ultra-high brightness 1000 кд/м² | Активные продажи |
| MU-231 | 23.1″ | UXGA 1600×1200 | AC100–230V | FAR-28X7, FAR-21X7 (universal version) | окончание срока действия |
| MU-270W | 27″ Widescreen | WUXGA 1920×1200 | AC100–230V | FAR-2xx8-NXT new-generation black-box radar, chart radar | Flagship Active Sales |
| MU-170C | 17″ | SXGA 1280×1024 | переменного тока | Older 17-inch universal display | окончание срока действия |
| MU-201C | 20.1″ | SXGA 1280×1024 | переменного тока | Older 20.1-inch universal display | окончание срока действия |
- MU-T Touch Series (New Bridge Integrated Displays, Not Direct MU-CR Replacement)
MU-170T: 17″ Трогать
MU-190T: 19″ Трогать
MU-240T: 24″ Трогать
Designed for integrated bridge systems, Ethernet MFD architecture. Not traditional DVI proprietary radar displays, cannot directly replace MU-231CR.
- Matched Radar Processor Cross Reference Table (Запасной & Sourcing Reference)
RPU-013 → MU-231CR / MU-231 (FAR2807/2817/2827)
RPU-024 → MU-190CR / MU-190 (FAR1513-BB / FAR1523-BB)
RPU-011 → MU-201CR (Legacy FAR2106 series)
SPU (FAR-2xx8-NXT new generation) → MU-270W
- Spare Replacement & Selection Critical Notes
- Original factory FAR28X7 radar ships with MU-231CR as standard. Do not directly substitute with universal MU-231; radar timing and ARPA compatibility risks exist, some radar revisions will reject the display.
- CR models reject PC and standard camera DVI sources and return No Signal; universal MU accepts multiple signal sources.
- Sourcing for discontinued CR models: Used pull-outs, refurbished units, old stock. New upgrade path is full radar system upgrade to FAR2xx8-NXT + MU-270W.
- Panel cutout dimensions: MU-231 and MU-231CR share identical cutout; MU-190 and MU-190CR share identical cutout.
- Excluded Models (Not Independent MU Radar Displays)
TZT Series (TZtouch): NavNet network MFD multifunction navigation terminal, not MU display
FR Series: Integrated radar (экран + transceiver built together), not standalone MU display
FMD Series: ECDIS chart plotters, not radar display units
Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер