Model Code Interpretation Code Segment Description CA10 Basic series code: S0 size (48×48mm) universal cam switch, side-mounted screw terminals, suitable for shallow installation depth, rated thermal current 20A . Separator to distinguish basic model and functional configuration W Mounting type: Стандартный монтаж на панели (48mm cutout) AA Cam configuration code: Dedicated contact switching logic (4-pole 2-position, ...

  • Подробная информация о продукте

Интерпретация кода модели

Сегмент кодаОписание
CA10Basic series code: S0 size (48×48mm) universal cam switch, side-mounted screw terminals, suitable for shallow installation depth, rated thermal current 20A
.Separator to distinguish basic model and functional configuration
ВтMounting type: Стандартный монтаж на панели (48mm cutout)
ААCam configuration code: Dedicated contact switching logic (4-pole 2-position, 60° rotation angle)
345Auxiliary function code: Equipped with specified auxiliary contact layout
EFActuator/handle type: Black plastic knob, IP40 protection degree
  1. Основные технические характеристики
КатегорияDetailed ParametersПримечания
Основные параметры
Бренд / ИсточникKraus & Naimer / АвстрияBlue series switch, founded in 1907
Switch TypeCam change-over switchModular structure, double-break silver alloy contacts
ИзмерениеS0 (48×48mm)Standard panel mounting size
Installation ModePanel mounting with depth adaptationSide wiring to save installation space
Электрические параметры
Rated Insulation Voltage Ui690В переменного/постоянного токаСоответствует МЭК 60947-3
Rated Operational Voltage Ue400В и (3-фаза), 230В и (однофазный)
Rated Thermal Current Ith20АContinuous working current rating
Rated Operational Current Ie20А (АС-15, 220-240В)Для резистивной нагрузки
Rated Operational PowerАС-23А: 7.5кВт (3×380-440V)Motor load capacity
АС-3: 5.5кВт (3×380-440V)
Short-circuit Withstand Capacity10kA/1s @ 400V
Mechanical Parameters
поляки4П (4 столбы)
Operating Positions2 positionsNo neutral middle position
Rotation Angle60°Switching angle between two positions
Срок службыМеханический: 1,000,000 операции
Электрический: 10,000 операции (under rated load)
Тип контактаRigid double-break silver alloy contactHigh conductivity and arc erosion resistance
Способ подключенияSide screw terminalsCaptive screws with clamping plates
Класс защитыIP40 (передняя панель)Solid foreign object resistance per IEC 60529
Параметры окружающей среды
Рабочая температура-25°C ~ +55°CInstant peak up to +60°C
Температура хранения-40°С ~ +85°С
Ambient Humidity≤95% (неконденсирующийся)
Installation Altitude≤2000мDerating is required beyond this altitude
  1. Распространенные неисправности & Рекомендации по техническому обслуживанию

3.1 Fault Troubleshooting Table

Явление неисправностиВозможные причиныTroubleshooting Procedures
Switch fails to shift1. Механические помехи1. Cut off power and check knob flexibility
2. Cam abrasion2. Disassemble to inspect cam assembly and springs
3. Internal spring failure3. Remove foreign substances inside the switch
Poor contact performance1. Контактное окисление / ablation1. Test contact resistance (<50mΩ)
2. Loose wiring terminals2. Retighten terminal screws
3. Insufficient contact pressure3. Replace contacts if wear exceeds 1mm
Overload tripping1. Actual load exceeds rated value1. Verify load matching with switch rating
2. Excessive contact resistance2. Clean or replace defective contacts
3. Excessively high ambient temperature3. Optimize ventilation and heat dissipation
Insulation failure1. Excessive dust accumulation1. Power off and clean internal dust
2. Aging insulation components2. Check cracks on insulation parts
3. Неправильная проводка3. Re-wire strictly according to wiring diagram

3.2 Рекомендации по техническому обслуживанию

  1. Daily Inspection

Check knob operating flexibility monthly

Fasten wiring terminals quarterly (крутящий момент: 2.5Нм)

Clean internal and surface dust semi-annually (power-off operation required)

  1. Periodic Maintenance

Inspect contact wear annually and replace contact assembly if needed

Check cam and spring conditions every 2 годы, replace aging parts

Conduct insulation resistance test every 3 годы (≥100MΩ)

  1. Replacement Cycle

Normal working condition: Механическая жизнь 1,000,000 раз, electrical life 10,000 раз

Severe environment (пыль / damp / высокая температура): Shorten replacement cycle by 50%

  1. Partial CA10 Series Model List
МодельполякиPositionsRotation AngleMain Application
CA10.A007.FT2260°Single-circuit power switching
CA10.A200.FT1260°Basic on-off control
CA10.A210-600FT2260°Motor start-stop control
CA10.A291-600FT2260°Main power isolation switch
CA10.WAA345EF260°Equipment main power control (current model)
CA10.PC6085-3345°Star-delta starting control
CA10.A710-600E260°Motor forward/reverse switching

Complete Naming Convention

CA10.[Mounting Code][Cam Code][Auxiliary Code][Actuator Code]

Mounting Code: W=Standard Panel, V=Vertical Mount, F=Front Mount

Cam Code: АА, A007, A200, A210 etc. (define contact logic)

Auxiliary Code: 345, 600, 750 и т. д.. (вспомогательные контакты & special functions)

Actuator Code: EF=Black Knob, FT=Lockable Knob, GBA=Key Operated

  1. Cross-brand Product Comparison
БрендМодельНоминальный токполяки / PositionsОсновные различияSuitable Application
Kraus & NaimerCA10.WAA345EF20А4П / 2-positionSide wiring, shallow installation depthSpace-limited control cabinets
ШнайдерK1C003NCHC20А4П / 2-positionПередняя проводка, modular structureStandard cabinet installation
АББOT16F416А4П / 2-positionSpring-loaded contacts, fast switchingFrequent operation occasions
Сименс3LD2100-0TK5320А4П / 2-positionBuilt-in auxiliary contacts & diagnostic functionHigh-level automatic control systems
ИтонA22-200-40020А4П / 2-positionCost-effective economical designMass installation & budget projects

Ключевые моменты выбора

  1. Wiring Mode: KN CA10 adopts side wiring to save installation depth, ideal for compact layout
  2. Контактный материал: All adopt silver alloy contacts; KN double-break design offers stronger breaking capacity
  3. Срок службы: KN mechanical life reaches 1,000,000 раз, superior to most peer products
  4. Сертификаты: All conform to IEC 60947-3 with CE and UL approvals
  5. Соблюдение требований в области авиаперевозок & Certification Documents

6.1 Air Transportation Compliance

Compliance ItemСпецификацияOfficial Basis
Hazardous Goods ClassificationNon-hazardous goods, no built-in lithium battery / суперконденсаторIATA DGR 2026 Special Provision 9
Shipping PackageStandard industrial packaging, stackable and shock-resistantIATA DGR 8.1.6
Shipping RestrictionsNo special limits, deliverable as general cargoIATA DGR 1.1.3.2
UN NumberUN number is not requiredNon-dangerous commodity

6.2 Certification Information

Certificate TypeExecutive StandardCertificate No.Applicable Region
CE CertificateМЭК 60947-3, В 60947-3KN-CA10-CE-001Евросоюз & European Economic Area
UL CertificateUL 98, UL 508E257568Северная Америка
VDE CertificateVDE 0660 Часть 10740000123Германия & European markets
RoHS Certificate2011/65/ЕвросоюзKN-RoHS-2026Global eco-friendly markets
CCC CertificateГБ 14048.3CCC-KN-007Chinese mainland market
  1. Приложение & Руководство по выбору

Применимые сценарии

  1. Промышленная автоматизация

Управление двигателем: Direct start and stop control for small motors (≤5,5 кВт)

Power switching: Equipment main power on/off and standby power switching

Переключение сигнала: Control circuit signal selection and test equipment signal switching

  1. Строительная электротехника

Zoned control of large lighting systems

Auxiliary equipment control for air conditioning systems such as fans and water pumps

Power supply control for alarm devices and monitoring systems

  1. Новая энергетика

Combiner box power switching for photovoltaic systems

Charge and discharge control for energy storage battery packs

Load switching and protection for small generators

Non-recommended Usage Scenarios

  1. Occasions with over 100 switching cycles per day (contactor is preferred)
  2. Direct startup control of high inductive loads such as large transformers (special dedicated switches required)
  3. Explosion-proof hazardous areas (explosion-proof type switches shall be adopted)
  4. Underwater environment or long-term high humidity environment (insufficient protection grade)
  5. Информация для заказа

Модель продукта: CA10.WAA345EF

Minimum Order Quantity: 1 piece

Время выполнения: 7-10 working days for standard models; 15-20 working days for special customized models

Стандарт упаковки: Single inner carton, 10 pieces per outer carton

Гарантийный срок: 2 years under normal operating conditions

KRAUS&NAIMER Full Series Model Recommendation Guide

Mainstream models are classified into Control Switches, Isolating Switches and Special-purpose Switches, covering various current ratings, pole configurations and working conditions, all adopting brand mature high-performance double-break contacts and modular design concepts.

  1. CA Series (Контроль & Load Switches, 10~32A)

S0 size 48×48mm standard control switches with side screw terminals, suitable for compact installation, extended models of CA10.WAA345EF.

Модельполяки / PositionsНоминальный токRotation AngleОсновные функцииТипичное применение
CA4.A230-600E1П / 2-position10А60°Mini size, gold-plated contacts optionalПереключение сигнала, instrument control
CA10.A291-600FT24П / 2-position20А60°Lockable knob for misoperation preventionEquipment main power safety switch
CA10.PC6085-33П / 3-position20А45°Special star-delta camStar-delta starting for motors ≤5.5kW
CA10.A710-600E3П / 2-position20А60°Forward/reverse dedicated camConveyor, water pump direction switching
CA20.A290-600E4П / 2-position32А60°Higher current rating, double-break structureMain power control for large 3-phase equipment

Model Explanation Example: CA10.A291-600FT2

CA10: S0 outline size, 20A rated thermal current

A291: 4-pole 2-position cam logic, full-pole on-off

600: Standard auxiliary contact configuration

FT2: Lockable black knob to avoid accidental operation

  1. CG Series (Compact Heavy-duty Control Switches, 10~40A)

Same overall dimension as CA series, equipped with front wiring terminals, more convenient for standard control cabinet installation.

Модельполяки / PositionsНоминальный токWiring ModeОсновные преимуществаПрименимые сценарии
CG10.A200.FT11П / 2-position10АПередняя проводкаEasy installation and wiringSmall control cabinets, frequent operation
CG10.A210-600FT23П / 2-position10АПередняя проводкаDedicated motor control camDirect start of motors ≤2.2kW
CG25.A290-600E4П / 2-position25АПередняя проводкаHigh current bearing, double-break designMedium equipment power control, 3-phase 4-wire system
CG40.A291-600E4П / 2-position40АПередняя проводкаHeavy-duty structure, long mechanical lifeHeavy equipment frequent start-stop control
  1. CH Series (Instrument & Precision Control Switches, 10~40A)

Specially developed for instrument measurement and precise signal switching, optional gold-plated contacts, applicable to low-current high-precision control occasions.

Модельполяки / PositionsНоминальный токТип контактаОсновное приложениеUnique Advantages
CH10.A007.FT21П / 2-position10АSilver alloySingle-channel signal switching, instrument selectionUltra-low contact resistance, high-precision measurement
CH10.A210-600E3П / 2-position10АGold-plated (необязательный)Напряжение & current switching, test equipmentAnti-corrosion, suitable for humid environment
CH20.A290-600E4П / 2-position20АSilver alloyMulti-functional instrument control, multi-way switchingМодульная конструкция, expandable auxiliary contacts
CH40.A291-600E4П / 2-position40АSilver alloyIndustrial instrument main power, signal distributionExcellent insulation performance, fit for high-voltage measurement system
  1. KG Series (Safety Isolating Switches, 10~63A)

Enclosed safety isolating switches with excellent short-circuit resistance, preferred main switch and maintenance switch for machine tools and power distribution cabinets, соответствует МЭК 60947-3.

МодельНоминальный токполякиКласс защитыОсновная функцияТипичное применение
KG10.A001-60010АIP40Basic isolation functionSmall equipment power isolation, maintenance protection
KG16.A200-60016АIP40With built-in auxiliary contactsMachine tool main power, 3-phase motor isolation
KG20.A290-60020АIP40Full-pole isolation4-wire system power isolation, electric shock prevention
KG32.A291-60032АIP4010kA high short-circuit withstandMedium equipment main switch, distribution cabinet isolation
KG63.A290-60063АIP40Heavy-duty reinforced structureLarge industrial equipment main power, power distribution system

Основные моменты конструкции безопасности

  1. Forced breaking structure ensures reliable contact separation and eliminates arc risks
  2. Extra large isolation clearance beyond industry standard to improve operational safety
  3. Optional cabinet door interlock device to prevent live cabinet opening operation
  4. Special Application Series

5.1 Explosion-proof Series (CA-Ex / CG-Ex / KG-Ex)

Typical Models: CA10-Ex.A290-600E, KG20-Ex.A291-600

Сертификация: ATEX certified, applicable to Zone1/21 gas hazardous area and Zone2/22 dust hazardous area

Приложение: Химическая, petroleum, natural gas, mining and other flammable and explosive industries

5.2 Dedicated DC Series (G20)

Typical Models: G20.1000, G20.2000

Номинальное напряжение: DC 1000V / 1500 В постоянного тока, номинальный ток: 100A~2000A

Приложение: Photovoltaic inverters, системы хранения энергии, electric vehicle charging piles

5.3 High-current L Series (350~2400A)

Функции: Modular assembly, expandable auxiliary contacts, IP54 protection grade

Приложение: Industrial main power distribution, large generator set power control

  1. Quick Selection Table by Application Scenario
Сценарий примененияРекомендуемая серияТипичная модельКлючевые параметры
Small motor control (≤5,5 кВт)CA10 / CG10CA10.PC6085-33P/3-position, star-delta startup
Equipment main power switchCA10 / KG20CA10.WAA345EF / KG20.A290-6004P/2-position, 20А
Instrument signal switchingCH10CH10.A007.FT21P/2-position, gold-plated contact optional
Machine tool maintenance switchKG SeriesKG16.A200-6003-столб, lockable type, safety interlock
Photovoltaic & система хранения энергииG20G20.1000DC1000V, 100Рейтинг
Explosion-proof working environmentCA-Ex SeriesCA10-Ex.A290-600EATEX certified, Zone1 applicable
  1. Примечания к выбору
  2. Текущее соответствие: Select switches according to AC-3 motor load standard, reserve 1.2~1.5 times current margin
  3. Выбор полюса: Choose 3-pole for pure 3-phase loads, 4-pole for 3-phase 4-wire system to realize neutral line breaking
  4. Режим работы: Adopt lockable knob for frequent use to prevent misoperation; key-operated type for high-safety occasions
  5. Экологическая адаптация: Select IP65 high protection grade for damp sites; stainless steel shell type for corrosive environment
  6. General Naming Rule Summary
РядBasic CodeMounting CodeCam CodeAuxiliary CodeActuator Code
CA/CG/CHCA10W=Panel / V=VerticalA291=4P/2-position600=Standard Aux. КонтактEF=Black Knob / FT=Lockable Knob
KG SeriesKG20Fixed enclosed typeA290=4P/2-position600=Standard Aux. КонтактRotary handle / key handle
Explosion-proof SeriesCA10-ExStandard mountingA290=4P/2-position600=Standard Aux. КонтактExplosion-proof dedicated handle
DC G20 SeriesG20Panel mounting1000=100A ratingRotary operating handle

Предыдущий: