LUCA05BL is a standard control unit of Schneider’s TeSys U series, suitable for three-phase motors. It features an adjustable rated current of 1.25–5A, a control voltage of 24V DC, and a Class 10 thermal overload rating. Equipped with protection against overload, short circuit, phase loss, phase interruption, and ground fault, it is designed for direct-on-line ...

  • Подробная информация о продукте

LUCA05BL is a standard control unit of Schneider’s TeSys U series, suitable for three-phase motors. It features an adjustable rated current of 1.25–5A, a control voltage of 24V DC, and a Class 10 thermal overload rating. Equipped with protection against overload, short circuit, phase loss, phase interruption, and ground fault, it is designed for direct-on-line starting control of motors below 1.5kW (400В).

ParameterValueDescription
Compatible SeriesTeSys UStandard control unit (LUCA series)
Номинальный ток (Ir)1.25–5AAdjustable; rated continuous current (Iu)=5A
Control Voltage24V DCOperating voltage of the control circuit
Thermal Overload ClassClass 10Соответствует МЭК 60947-4-1
Main Circuit Voltage≤690V ACSuitable for three-phase motors
Motor Power (400В)≤1.5kWThree-phase, 50/60Гц
Защита от короткого замыкания65А (instantaneous)Non-adjustable
Функции защитыOverload/Short Circuit/Phase Loss/Current Unbalance/Ground FaultManual reset required
Размеры (W×H×D)45×66×60mmStandard modular installation
Place of OriginФранцияOriginal imported product

Product Positioning & Applications

As a standard control unit of the TeSys U series, it combines with compatible power bases (например, LUB05) to form a direct-on-line starter, providing basic control and protection for three-phase motors.

Сценарии применения: Light to medium-load working conditions such as pumps, фанаты, compressors, and small conveyor lines, suitable for industries including textile, papermaking, chemical engineering, and food & beverage.

Differentiation from Series Peers: Unlike LUCB (advanced type with alarm/test functions) and LUCC (communication type), LUCA only provides basic protection with a lower cost.

Selection & Replacement

Compatible Bases: LUB05, LUB05BL, и т. д.. The base must match the rated current of the control unit.

Replacement References: Equivalent models from Chint NJR2 series and ABB MS116 series. Однако, interface and protection logic differences exist; it is necessary to verify installation dimensions and control circuit parameters.

Installation & Maintenance Guidelines

  1. Install via DIN rail or screw mounting; modular plug-and-play design enables quick replacement.
  2. The control circuit requires an external 24V DC power supply. Set Ir (1.25–5A) on the main circuit according to the motor’s rated current.
  3. Manual reset is required after a fault. Ground fault protection is only for equipment and does not replace personal safety protection.
  4. Диапазон рабочих температур: -25~+60℃. Avoid dusty, humid, and corrosive environments; regularly check wiring and terminal tightness.

Procurement & Supply

Common Channels: Schneider authorized distributors, industrial e-commerce platforms. Reference price: approximately €60–100 (tax included). In-stock delivery typically takes 2–5 working days.

Compatible Accessories: Can be paired with LUFDA local alarm module and LULC remote signal module to expand status monitoring functions.

Detailed Comparison Between Schneider TeSys U Series LUCA05BL and LUCB05BL

Размер сравненияLUCA05BL (Standard Type)LUCB05BL (Advanced Type)
Core PositioningBasic motor protection & direct-on-line starting controlEnhanced protection + сигнализация неисправности + test functions
Диапазон номинального тока1.25–5A1.25–5A
Control Voltage24V DC24V DC
Thermal Overload ClassClass 10 (МЭК 60947-4-1)Class 10 (МЭК 60947-4-1)
Compatible Motor Power (400В)≤1.5kW≤1.5kW
Main Circuit Voltage≤690V AC≤690V AC
Basic Protection FunctionsПерегрузка, short circuit, phase loss, current unbalance, ground faultSame as LUCA05BL, plus overload pre-alarm function
Special FeaturesManual reset only; no alarm/test functions1. Fault alarm output: Relay contact signal, connectable to indicator lights or PLC
2. Manual test function: Simulate faults without power supply to verify protection logic
3. Status indication: Multi-color LED distinguishes running/overload/short circuit/phase loss status
Reset MethodManual reset onlyРучной сброс + external remote reset signal support (accessories required)
Modular Accessory CompatibilitySupports basic bases only (например, LUB05)Compatible with LUFDA local alarm module and LULC remote signal module; supports expansion
Способ установкиDIN rail/screw mounting; plug-and-playSame as LUCA05BL; consistent installation dimensions
Сценарии примененияLight/medium-load conditions without remote monitoring needs (например, small pumps, фанаты)Scenarios requiring fault pre-alarm and status monitoring (например, automated production lines, chemical equipment)
Cost Reference€60–100 (tax included)€120–180 (tax included), approximately twice the price of LUCA05BL
Replacement CompatibilityBase-compatible with LUCB05BL; direct plug-and-replaceDownward compatible with LUCA05BL replacement; redundant functions but higher cost

Key Difference Summary

  1. Functional Differences: The core advantages of LUCB05BL are overload pre-alarm + сигнализация неисправности + manual test, which can detect motor overload trends in advance to avoid downtime losses. In contrast, LUCA05BL only provides post-fault protection with no pre-alarm capability.
  2. Expansion Capability: LUCB05BL can be connected to external alarm lights, PLCs, or remote monitoring modules to adapt to automated systems; LUCA05BL has no expansion interface and only meets basic control needs.
  3. Cost & Cost-Effectiveness: LUCA05BL is suitable for cost-sensitive scenarios with simple working conditions; LUCB05BL is ideal for industrial scenarios requiring high reliability. Although it has a higher price, it can reduce fault troubleshooting time and maintenance costs.

Рекомендации по выбору

If end customers only requirebasic motor protection against damage”, prioritize LUCA05BL for higher cost-effectiveness.

If customers operate in scenarios such as automated factories and production lines that require fault pre-alarm and remote monitoring, recommend LUCB05BL to improve equipment operation rate.

Cross-Brand Selection Comparison Table: Schneider LUCA05BL/LUCB05BL vs. Chint NJR2-5 vs. ABB MS116-5

Размер сравненияSchneider LUCA05BLSchneider LUCB05BLChint NJR2-5ABB MS116-5
Product Series PositioningTeSys U standard control unitTeSys U advanced control unitNJR2 series thermal overload relayMS116 series motor starter protection circuit breaker
Диапазон номинального тока1.25–5A (регулируемый)1.25–5A (регулируемый)1.6–5A (регулируемый)1.6–5A (регулируемый)
Control Voltage24V DC24V DCNo control circuit (passive)No control circuit (passive)
Thermal Overload ClassClass 10Class 10Class 10Class 10
Compatible Motor Power (400В)≤1.5kW≤1.5kW≤1.5kW≤1.5kW
Main Circuit Voltage≤690V AC≤690V AC≤660V AC≤690V AC
Core Protection FunctionsOverload/Short Circuit/Phase Loss/Current Unbalance/Ground FaultOverload+Short Circuit+Phase Loss+Current Unbalance+Ground FaultПерегрузка, Phase Interruption, Current UnbalanceПерегрузка, Short Circuit, Phase Loss, Current Unbalance
Overload Pre-Alarm, Fault Alarm OutputNo short circuit/ground fault protectionNo ground fault protection
Special FeaturesРучной сбросManual/remote resetManual/automatic reset optionKnob-type current adjustment
Modular plug-and-playFault alarm contactКомпактный размер, low costIntegrated circuit breaker function
Manual test functionManual closing/opening operation
Accessory expansion support
Способ установкиDIN rail/screw mountingDIN rail/screw mountingDIN rail mountingDIN rail mounting
Requires TeSys U base (например, LUB05)Compatible with full range of TeSys U basesDirect combination with contactorsIntegrated design, no base required
Сценарии примененияLight-load conditions, cost-sensitive scenariosAutomated production lines, fault pre-alarm required scenariosDomestic industrial supporting, low-end equipment supportingMid-to-high-end industrial scenarios requiring integrated circuit breaker functions
Small pumps/fansChemical/textile equipmentDistribution boxes/pumps & фанатыProduction lines/compressors
Cost Reference (Tax Included)€60–100€120–180RMB 80–150€90–160
Replacement CompatibilityBase-compatible with TeSys UBase-compatible with LUCA05BLSimple wiring; cross-brand replacement of international models requires mounting hole adjustmentIntegrated design; cross-brand replacement requires main circuit wiring matching
Cross-brand replacement requires wiring modificationDirect replacement for LUCA05BL

Key Selection Conclusions

  1. Chint for Cost Priority: NJR2-5 has the lowest price, suitable for domestic low-end equipment supporting, but lacks short circuit and ground fault protection and needs to be used with additional circuit breakers.
  2. ABB for Integrated Control: MS116-5 is an integrated protection circuit breaker with built-in closing/opening functions, requiring no base matching, suitable for scenarios with high integration requirements.
  3. Schneider LUCB for Automated Scenarios: Equipped with alarm and test functions, it can be connected to PLCs for remote monitoring, reducing fault troubleshooting time, ideal for high-end production lines.
  4. Schneider LUCA for Basic Protection: Balanced functions with a lower price than LUCB and ABB, suitable for overseas small and medium-sized customers without monitoring needs.

Export Adaptation Tips (For Markets Such as Algeria)

Both Schneider and ABB products are certified by IEC and CE, directly meeting the import certification requirements of African countries such as Algeria.

Chint NJR2-5 requires additional local access documents such as SASO certification. Some channels can handle the certification on behalf of customers, with a cost increase of approximately 10%–15%.

Предыдущий:

Следующий:

Оставить ответ