| Модельный сегмент | Описание |
| фр. | General prefix for Mitsubishi inverters (Frequency Inverter) |
| A840 | Standard model of A800 series for 400V class, high-performance vector control for general industrial use |
| 2600 | Capacity code, corresponding to Normal Duty (ND) 90kW/180A, Super Light Duty (SLD) 132kW/260A |
| 2 | CA type (current control, standard 0–20mA analog input) |
| 60 | Conformal coating on circuit boards, non-plated conductors, enhanced environmental resistance |
- Core Electrical Specifications
| Элемент | Normal Duty (ND) | Super Light Duty (SLD) | Light Duty (LD) |
| Применимая мощность двигателя | 90кВт (150Hp.) | 132кВт (177Hp.) | 110кВт (147Hp.) |
| Rated Output Current | 180А | 260А | 216А |
| Input Power | 3-phase AC 380–480V, 50/60Гц (±10% tolerance) | ||
| Output Voltage | 3-phase AC 0–input voltage, proportional to input voltage | ||
| Output Frequency | 0.2–590Hz (max 400Hz in vector control mode) | ||
| Метод управления | Sensorless Vector Control (RSV), V/F Control, PM Sensorless Vector Control, compatible with Induction Motors (IM) and Permanent Magnet Motors (IPM) | ||
- Ключевые особенности
- High‑Performance Control
Universal vector control, high torque at low speed; 150% rated torque at 0.5Hz
Built-in PID controller for various closed-loop applications
Automatic energy-saving operation, adjusts output voltage according to load to reduce power consumption
- Структура & Защита
Protection class IP00 (open type), suitable for cabinet mounting
Circuit boards with conformal coating (соответствует МЭК 60721-3-3), resistant to dust, oil, and humidity
Comprehensive protection: сверхток, перенапряжение, пониженное напряжение, перегрев, замыкание на землю, motor overload, phase loss protection, и т. д..
- Built-in Interfaces & Expandability
Standard RS-485 communication (Modbus RTU protocol)
Supports various fieldbus extensions: PROFIBUS-DP, DeviceNet, ЭтерНет/IP, и т. д..
Analog inputs: 2 каналы (0–10 В / 0–20 мА, 1 channel dedicated for CA-type 0–20mA)
Цифровой ввод/вывод: 5 inputs, 2 результаты (расширяемый)
- Перегрузочная способность & Environmental Parameters
| Тип нагрузки | Перегрузочная способность | Условия окружающей среды |
| Normal Duty (ND) | 150% rated current for 60s, 200% rated current for 3s (inverse-time characteristic) | Operating temp: -10℃to 50℃C (derating above 40℃C) |
| Super Light Duty (SLD) | 110% rated current for 60s, 120% rated current for 3s | Storage temp: -20℃ to 65℃ |
| Light Duty (LD) | 120% rated current for 60s, 150% rated current for 3s | Относительная влажность: 5% к 95% (неконденсирующийся) |
- Типичные применения
General industrial machinery: компрессоры, насосы, фанаты, конвейеры, миксеры, и т. д..
Metal processing: шпиндели станков, winding equipment, wire drawing machines
Lifting & conveying: краны, лифты, automated storage systems
Chemical & фармацевтический: mixing, reaction, and conveying equipment in process industries
Building & ОВК: air conditioning systems, насосы, fan energy-saving control
- Установка & Selection Guidelines
- Требования к установке
Forced-air cooling; ensure sufficient ventilation (≥100mm clearance on all sides)
Монтировать вертикально, avoid direct sunlight and corrosive gas environments
Recommended input reactor and EMC filter for improved stability and EMC performance
- Примечания к выбору
Select load rating based on actual load type (constant torque / variable torque)
For frequent starting/stopping or heavy starting, select one frame size larger than motor power
For long cable runs, consider voltage drop and dv/dt effects; install output reactor if necessary
- Сменные модели & Информация для заказа
Прямая замена: FR-A840-02600-E2-60 (European version, no built-in DC reactor)
Upgraded model: FR-A840-02600-E2-60CRN (with Ethernet interface)
Official order number: 297582 (base model)
The Mitsubishi FR-A840-02600-2-60 is a high-performance, high-reliability 400V-class vector inverter, ideal for driving medium-to-high power motors and providing precise speed and torque control in various industrial automation scenarios. Its CA-type control and conformal coating ensure excellent performance in harsh industrial environments.
Mitsubishi FR Series Inverter Model List & Cross-Brand Comparison
- Classification & Model Meaning of Mitsubishi FR Series
1.1 Series Overview
| Ряд | Voltage Class | Диапазон мощности | Core Position | Типичные применения |
| FR-A800 | 200В (FR-A820) / 400В (FR-A840) | 0.4kW–500kW | Flagship high-performance vector control | Heavy industry, high-precision torque control, complex motion control |
| FR-F800 | 200В (FR-F820) / 400В (FR-F840) | 0.4kW–400kW | Energy-saving for fans & насосы | ОВК, water treatment, building automation |
| FR-E800/FR-E700 | 200V/400V | 0.1kW–22kW | Compact general-purpose | Packaging machinery, food & beverage, small production lines |
| FR-D800/FR-D700 | 200V/400V | 0.1kW–75kW | Easy-to-use economy type | Small fans/pumps, конвейеры, general machinery |
| FR-CS80 | 200V/400V | 0.4kW–315kW | Heavy-duty special type | Cranes, winders, metallurgical equipment |
| FR-B | 200V/400V | 0.4kW–75kW | Explosion-proof special type | Hazardous areas such as chemical, petroleum, coal mines |
1.2 Full Model Format Explanation
Standard format: FR-XXX-YYYYY-Z-W
| Поле | Значение | Пример |
| фр. | General prefix for Mitsubishi inverters (Frequency Inverter) | – |
| XXX | Код серии + voltage class | A840 (400V high-performance), F820 (200V fan/pump) |
| YYYYY | Capacity code/power identifier | 02600 (90kW/180A), 15K (15кВт) |
| З | Control type | 1 (стандартный, 0–10 В), 2 (CA type, 0–20 мА), E2 (European version, no built-in DC reactor) |
| Вт | Special functions | 60 (conformal coating), CRN (Ethernet), R2R (winding dedicated) |
- Complete Model List of Mitsubishi FR Series Inverters
2.1 FR-A840 (400V High-Performance Vector Control) Core Models
| Применимая мощность двигателя | ND Current | SLD Current | Base Model | Special Model |
| 0.75кВт | 2.1А | 3.0А | FR-A840-00038-2-60 | FR-A840-00038-E2-60 |
| 1.5кВт | 3.7А | 5.3А | FR-A840-00052-2-60 | – |
| 2.2кВт | 5.0А | 7.2А | FR-A840-00072-2-60 | – |
| 5.5кВт | 11.5А | 16.5А | FR-A840-00170-2-60 | – |
| 11кВт | 23А | 33А | FR-A840-00330-2-60 | – |
| 15кВт | 30А | 43А | FR-A840-00430-2-60 | – |
| 30кВт | 60А | 86А | FR-A840-00860-2-60 | FR-A840-00860-E2-60 |
| 90кВт | 180А | 260А | FR-A840-02600-2-60 | FR-A840-02600-E2-60 |
| 132кВт | 240А | 345А | FR-A840-03450-2-60 | – |
| 280кВт | 500А | 720А | FR-A840-07200-2-60 | – |
2.2 Representative Models of Other Main Series
| Ряд | Репрезентативная модель | Власть | Ключевые особенности |
| FR-F840 | FR-F840-5.5K-2 | 5.5кВт | Fan/pump dedicated, built-in PID, energy-saving control |
| FR-E740 | FR-E740-1.5K-CHT | 1.5кВт | Компактный, built-in EMC filter |
| FR-D740 | FR-D740-7.5K-CHT | 7.5кВт | Simple operation, экономически эффективный |
| FR-A820 | FR-A820-37K-1 | 37кВт | 200V high-performance, suitable for light industry |
- Cross-Brand Inverter Comparison Table
Below shows functional and power matching between Mitsubishi FR series and major brands including Siemens, Шнайдер, АББ. Precise selection should consider actual load characteristics and control requirements.
| Mitsubishi Model | Siemens Equivalent | Schneider Equivalent | ABB Equivalent | Functional Match |
| FR-A840-02600-2-60 (90кВт) | SINAMICS G120C 90kW | ATV630D11N4 | ACS580-01-180A-4 | High-performance vector control, suitable for heavy-duty applications |
| FR-F840-5.5K-2 (5.5кВт) | SINAMICS G120X 5.5kW | ATV610U75N4 | ACS580-01-015A-4 | Fan/pump dedicated, energy-saving control |
| FR-E740-1.5K (1.5кВт) | SINAMICS V20 1.5kW | ATV320U15N4 | ACS180-04-03A3-4 | Compact general-purpose |
| FR-A820-37K-1 (37кВт, 200В) | SINAMICS G120 37kW 200V | ATV630D45N2 | ACS580-04-075A-2 | Medium-power vector control for 200V systems |
| FR-CS840-110K (110кВт) | SINAMICS S120 110kW | ATV930D160N4 | ACS880-01-246A-3 | Heavy-duty, four-quadrant operation |
- Ключевые моменты выбора & Примечания
- Load Matching Principles
Constant torque loads (конвейеры, миксеры): select FR-A800 series, rated by ND current
Variable torque loads (фанаты, насосы): select FR-F800 series, rated by SLD current
Frequent start/stop or heavy starting: select one size larger than motor power
- Special Environment Adaptation
Harsh industrial environments: prefer models with “60” суффикс (conformal coating: FR-A840-XXXXX-2-60)
Explosive/flammable environments: select FR-B series explosion-proof inverters
Ethernet-связь: select models with “CRN” суффикс
- Установка & Maintenance Tips
Vertical mounting, ≥100mm clearance on all sides for ventilation
For long cables, recommend output reactor to reduce dv/dt influence
Regular inspection of cooling fans and capacitors for long-term stable operation
Mitsubishi FR series inverters cover a full power range from 0.1kW to 500kW, meeting diverse needs from basic control to high-precision motion control via differentiated series positioning. For cross-brand selection, focus on core parameters including control method, overload capacity, протокол связи, and environmental resistance to ensure system compatibility and stability.
Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи





















NH42-63-318x560.png)