Полное название продукта: Grooved photoelectric switch with built-in amplifier, 1 оптическая ось, ПНП-выход
✅ Model Code Explanation
E3Z: Series of фотоэлектрический датчикs with built-in amplifier
Г: Grooved / U-type through-beam
8: ПНП-выход (6 = NPN)
1: Single optical axis (2 = Dual optical axis)
Суффикс:
2М: Fixed cable, 2длина м (Most common model in China)
-M3J 0.3M: M8 4-pin pre-wired connector, 0.3m lead
-M1J-1 0.3M: M12 4-pin pre-wired connector, 0.3m lead
📋 Core Technical Specifications
| Элемент | Параметр |
| Метод измерения | U-slot through-beam, single optical axis |
| Groove Width (Sensing Gap) | 25 мм |
| Источник света | Инфракрасный светодиод, 940нм |
| Standard Sensing Object | Opaque object ≥φ1.5mm |
| Источник питания | DC 12~24V (±10%) |
| Тип выхода | ПНП с открытым коллектором, max load 100mA |
| Режим работы | Свет-ВКЛ. / Dark-ON selectable |
| Время ответа | Operate / Reset ≤1ms |
| Текущее потребление | ≤25mA |
| Защита | Reverse power protection, защита от короткого замыкания на выходе, mutual interference resistance |
| Класс защиты | IP64 |
| Рабочая температура | -25℃ ~ +55 ℃ (No icing or condensation) |
| Материал корпуса | АБС |
| Ambient Light Immunity | Incandescent lamp ≤3000lx, Sunlight ≤10000lx |
🛠️ Application Scenarios
The grooved photoelectric sensor triggers signal when an object blocks the infrared beam inside the U-slot:
Conveyor material counting & обнаружение положения
Home position / limit detection for cylinders and slides
Door switch detection for elevator and automation equipment
Label detection, notch detection for disc parts
High-speed sorting and stepping positioning (1ms response suitable for high-speed applications)
📌 Wiring Instruction (E3Z-G81 2M cable version, Brown/Blue/Black/White)
- Коричневый: DC+ 12~24V
- Синий: DC0V
- Черный: PNP signal output wire
- Белый: Mode selection wire (Light ON / Dark ON)
White wire connected to DC+: Dark ON (Light-blocked ON, normally closed logic); White wire floating: Light ON (Light-received ON, normally open logic)
⚠️ Model Selection & Troubleshooting Key Points
- Distinguish NPN/PNP: E3Z-G61 = NPN; E3Z-G81 = PNP. PLC input module polarity must match.
- Dust and debris accumulated in slot will block infrared light and cause false triggering; IP64 rating, NOT suitable for heavy water spray environments.
- Detected object must be opaque; transparent plastic or thin translucent sheets cannot be reliably detected.
- Dual optical axis model: E3Z-G82, used to prevent false detection of single optical axis, for dual-position signal acquisition.
🔁 Replacement Reference
Отечественная альтернатива: U-groove photoelectric sensor, 25mm slot width, ПНП, 24 В постоянного тока, 1ответ мс (совместим с ОМРОН E3Z-G series, brands like Shenwu, Senso etc.)
Interchange within series: E3Z-G81 (Single axis PNP) ↔ E3Z-G61 (Single axis NPN); E3Z-G82 (Dual axis PNP)
HS Code Reference
85414090 (Photosensitive semiconductor device, фотоэлектрический датчик, for customs declaration only, subject to customs final verification)
OMRON E3Z-G81 Grooved Photoelectric Sensor Installation Guide
Применимые модели: E3Z-G81 (2м кабель), E3Z-G81-M3J (M8 0.3m pre-wired connector, PNP single-axis grooved photoelectric)
25mm groove width, built-in amplifier, IP64, 12~24В постоянного тока, Light ON / Dark ON selectable
- Проверка перед установкой
- Unboxing Verification
Confirm model E3Z-G81; Inspect housing, transmitter/receiver windows inside slot for scratches, damage and oil contamination
Check cable integrity; Confirm orange operation indicator is intact
- Проверка окружающей среды
Температура окружающей среды: -25℃ ~ +55 ℃, отсутствие обледенения и конденсата
Prohibited: Direct sunlight / strong incandescent light on optical path, агрессивный газ, continuous water spray, heavy dust accumulation, heavy vibration and shock
Avoid routing signal cable closely in parallel with inverter, contactor and power cables (EMI causes false triggering)
- Workpiece Verification
Sensing object: Opaque solid, minimum detectable size ≥φ1.5mm; Thin transparent sheets cannot be reliably sensed
Workpiece moving direction: Pass perpendicularly through the optical axis of U-slot, avoid sweeping the beam diagonally
- Mechanical Installation Procedure
2.1 Способ монтажа
E3Z-G81 housing has built-in M3 mounting holes, fixed with M3 screws
Рекомендуемый момент затяжки: ≤0.5 N·m. Excessive torque may crack ABS housing. Never strike sensor body with hammer; it will damage IP seal and optical path.
Optional OMRON E39 mounting bracket for rack installation
2.2 Монтажное положение & Optical Path Requirements (Критический)
- Workpiece must fully pass through the optical axis at center of U-slot and completely cut off infrared beam when blocked
- Keep clearance between workpiece and slot wall. Do not scratch transmitter/receiver window to avoid lens scratch and dust buildup
- Workpiece thickness: Opaque material is acceptable; Workpiece entering/exiting slot must not impact sensor housing
- Multiple grooved sensors mounted side by side: Keep sufficient spacing to prevent mutual optical interference
- Sensor may be mounted directly on metal frame; U-groove type is immune to reflection from nearby metal surfaces.
✅ Installation Verification: Orange indicator toggles when workpiece enters slot to block beam, and recovers after workpiece exits.
2.3 Cable Installation Specification
- Cable bending radius ≥ 4 × cable outer diameter; Avoid repeated bending near cable root; Max cable tension ≤50N. Never pull sensor body by cable force
- Separate signal cable and power cable into different conduits, not in same trunking; If parallel routing is unavoidable, maintain ≥10cm spacing
- Cable extension: Extended wire cross-section ≥0.3mm², total length ≤100m; Insulate terminals properly
- Connector version (E3Z-G81-M3J): Do not pull cable during M8 connector plug/unplug; Tighten thread fully; Inspect connector seal regularly
- Электрическая проводка (Perform under power OFF! Wiring with power ON is prohibited)
3.1 Cable outlet model (E3Z-G81, 4-основной: Коричневый, Синий, Черный, Белый)
| Цвет провода | Определение | Примечание |
| Коричневый | DC+ | 12~24V DC Positive |
| Синий | округ Колумбия- | 0V Отрицательный |
| Черный | PNP Output | Connect to PLC input point, max load 100mA |
| Белый | Mode Selection Wire | Floating = Light ON; Connected to DC+ = Dark ON |
ПНП-выход: High level active; PLC input module requires sourcing input.
3.2 M8 Connector Model E3Z-G81-M3J (4-приколоть)
Контакт 1: Brown DC+; Контакт 3: Blue DC-; Pin4: Black Output; Контакт 2: White Mode Selection (can be left unused)
3.3 Pre-power Check
Power supply DC12~24V, ±10%; Do NOT connect AC220V
Confirm power polarity without reverse connection; Sensor has built-in reverse polarity & защита от короткого замыкания, but wiring verification is still required
Нагрузка (вход ПЛК) wired correctly; Never short output directly
- Этапы ввода в эксплуатацию при включении питания
- Complete mechanical fixing and wiring with power OFF, double check
- Включение питания, slot unblocked (beam passes):
Light ON (white wire floating): Beam received, orange LED ON, PNP output activated
Dark ON (white wire connected to +24V): Beam received, orange LED OFF, output deactivated
- Insert opaque workpiece into slot to block optical path:
Light ON: Beam blocked, indicator OFF, output deactivated
Dark ON: Beam blocked, indicator ON, PNP output activated
- Test workpiece in/out repeatedly to verify stable indicator and PLC signal
- If signal jitters, проверять: ① Workpiece fully blocks beam; ② Dust on window; ③ EMI from power cable; ④ Loose mounting and vibration
- Обслуживание
- Regular cleaning of transmitter and receiver windows inside U-slot: Wipe gently with lint-free cloth and anhydrous alcohol. Hard brush and strong solvent (acetone, thinner) are forbidden; they corrode ABS and optical lens
- Periodic inspection: Ослабленные винты, damaged cable jacket, water/oil ingress at connector
- Increase cleaning frequency for heavy dust environment
- Prohibited: Direct water or oil spray onto sensor body
- Installation Taboos & Примечания по безопасности
- Not for explosive hazardous area
- Cannot be immersed or continuously splashed; IP64 only protects against splashing water
- Do not touch internal infrared LED by hand
- High vibration equipment: Add lock washers and retorque screws periodically
- Never unplug cable or disassemble sensor when powered ON
- Quick Troubleshooting for Common Installation Issues
| Симптом | Возможная причина | Решение |
| Indicator not lit after power on | Нет источника питания, обратная полярность | Measure DC24V between Brown & Синий, recheck wiring |
| Continuous output without workpiece blocking | Wrong operation mode; Dust on lens transmits light; Strong ambient light interference | Switch mode; Clean lens; Avoid direct strong light |
| No signal when workpiece blocks beam | Workpiece translucent; Beam not fully cut; Mounting offset | Replace opaque workpiece; Adjust sensor position to ensure beam cut-off |
| Intermittent signal fluctuation | Loose mounting; EMI from power cable; Debris in slot | Tighten screws; Separate cable routing; Clean dust/debris in slot |
OMRON E3Z-G81 Grooved Photoelectric Sensor with Built-in Amplifier
Complete Product Manual (Английский, sourced from OMRON official E3Z-G datasheet)
Применимые модели: E3Z-G81 2M (2м фиксированный кабель), E3Z-G81-M3J (4-контактный разъем M8, 0.3m lead)
- Обзор продукта
E3Z-G81 is U-shaped grooved through-beam photoelectric sensor with built-in amplifier, single optical axis, PNP open-collector output; groove width 25mm. Detects objects when opaque material blocks infrared beam inside U-slot. Switchable between Light ON / Dark ON, response time ≤1ms, suitable for high-speed positioning, counting and home detection.
Классификация серий:
E3Z-G81: Single axis PNP; E3Z-G82: Dual axis PNP
E3Z-G61: Single axis NPN; E3Z-G62: Dual axis NPN
- Модельный состав
E3Z-G81
E3Z: Photoelectric sensor series with built-in amplifier
Г: Grooved U-slot type
8: ПНП-выход (6=NPN)
1: Single optical axis (2=Dual optical axis)
Суффикс:
2М: Fixed cable, length 2m (стандартная версия)
-M3J: M8 4-pin pre-wired connector, 0.3m lead
- Rated Specifications & Производительность
| Элемент | Параметр |
| Метод измерения | Grooved through-beam (U-slot) |
| Groove Width (Sensing Gap) | 25 мм |
| Number of Optical Axes | 1 оптическая ось |
| Источник света | Инфракрасный светодиод, wavelength 940nm |
| Standard Sensing Object | Opaque object ≥φ1.5mm; Transparent object cannot be reliably sensed |
| Напряжение питания | DC12~24V ±10%, ripple p-p ≤10% |
| Текущее потребление | ≤25mA |
| Выход управления | ПНП с открытым коллектором; Max load current 100mA; Residual voltage ≤1V; Max load supply DC26.4V |
| Режим работы | Light ON / Dark ON, selected by white control wire |
| Время ответа | Operate / Reset ≤1ms |
| Protection Circuit | Reverse power protection, защита от короткого замыкания на выходе, mutual interference prevention |
| Ambient Illuminance (Получатель) | Incandescent lamp ≤3000lx; Sunlight ≤10000lx |
| Рабочая температура | -25℃ ~ +55 ℃ (No icing, нет конденсата) |
| Температура хранения | -40℃ ~ +70 ℃ |
| Влажность | Операция:35~85%RH; Хранилище:35~95%RH (Нет конденсата) |
| Сопротивление изоляции | ≥20MΩ (DC500V, between cables and housing) |
| Выдерживать напряжение | AC1000V, 50/60Гц, 1мин (between cables and housing) |
| Vibration Durability | 10~55Hz, full amplitude1.5mm, X/Y/Z axes for 2h each |
| Shock Durability | 500м/с², X/Y/Z axes, 3 times each |
| Класс защиты | IP64 (стандарт МЭК, splash-proof, NOT immersion-proof) |
| Материал корпуса | АБС |
| Индикатор | Оранжевый индикатор работы |
| Масса | 2M cable version ≈65g; M8 connector version≈30g |
| MTTFd | 817 годы |
- Dimension Outline (Единица: мм)
U-shaped body, Монтажные отверстия М3; 25mm slot opening, two built-in M3 screw holes.
Рекомендуемый момент затяжки: ≤0.5 N·m. Excessive torque may crack housing.
Дополнительный аксессуар: E39 mounting bracket (продается отдельно)
- Определение проводки
5.1 Cable Outlet Version E3Z-G81 2M (4-основной: Коричневый, Синий, Черный, Белый)
| Цвет провода | Сигнал | Описание |
| Коричневый | DC+ | DC12~24V Positive |
| Синий | округ Колумбия- | 0V Отрицательный |
| Черный | PNP Output | Выходной сигнал, connect to PLC sourcing input |
| Белый | Mode Selection Wire | Floating = Light ON; Connected to DC+ = Dark ON |
5.2 M8 Connector Version E3Z-G81-M3J (4-приколоть)
| Контактный номер. | Corresponding Wire | Функция |
| 1 | Коричневый | DC+ |
| 3 | Синий | округ Колумбия- |
| 4 | Черный | PNP Output |
| 2 | Белый | Mode Selection Wire |
✅ Operation Logic
- Light ON (White wire floating, заводская настройка по умолчанию)
Beam unblocked (no obstruction): Orange LED ON, PNP output ON (Высокий уровень);
Beam blocked: Orange LED OFF, output OFF.
- Dark ON (White wire connected to DC+)
Beam unblocked (no obstruction): Orange LED OFF, output OFF;
Beam blocked: Orange LED ON, PNP output ON (Высокий уровень).
- Требования к установке
- Fix with M3 screws, add lock washer, torque ≤0.5N·m. Do not strike sensor body.
- Workpiece passes perpendicularly through U-slot optical axis; workpiece movement must not scratch or impact transmitter/receiver window.
- Keep enough spacing for multiple grooved sensors mounted side by side to prevent mutual optical interference.
- Separate signal cable and power cable; ≥100mm spacing if parallel routing is mandatory. Cable minimum bending radius ≥4 × cable OD; Max cable tension ≤50N.
- Среда установки: Avoid direct strong light on optical path, агрессивный газ, continuous water spray and heavy dust accumulation.
- Commissioning Steps
- Wire with power OFF, confirm no AC220V miswiring, check polarity.
- Включение питания, slot unobstructed, observe orange indicator to verify operation mode.
- Insert opaque workpiece into slot to cut beam, observe indicator state flip and verify PLC input signal.
- Repeat workpiece in/out test to confirm stable signal without jitter.
- Обслуживание
- Regular cleaning of U-slot transmitter and receiver windows: Wipe gently with lint-free cloth dipped in anhydrous alcohol. Acetone, thinner and other strong solvents are forbidden; hard material scratch on lens is prohibited.
- Regular inspection for loose mounting screws, damaged cable jacket and connector seal integrity.
- Increase cleaning frequency for dusty environment. Do not spray water or oil directly onto sensor.
- Примечания по безопасности
- This product cannot be used in explosive hazardous areas; IP64 only protects splash water and cannot resist immersion.
- Do NOT plug/unplug cable or disassemble sensor while powered ON.
- Load current of output must not exceed 100mA, otherwise internal circuit damage occurs.
- Do not touch infrared LED emitting surface by hand.
- This sensor is for general industrial detection, cannot be directly used as safety protective device (safety light curtain).
- Troubleshooting Table
| Явление неисправности | Первопричина | Решение |
| Indicator not lit after power on | Нет источника питания, обратная полярность питания | Measure DC24V between Brown & Синий, recheck wiring |
| Continuous output without workpiece blocking | Wrong mode setting; Dust on lens transmits light; Strong ambient light interference | Switch mode; Clean lens; Avoid direct strong light |
| No output signal when workpiece blocks beam | Workpiece translucent; Beam not cut fully; Mounting offset | Replace opaque workpiece; Adjust sensor position |
| Intermittent signal jitter | Loose mounting; EMI from power cable; Dust/debris in slot | Tighten screws; Separate cable routing; Clean debris inside slot |
- Аксессуары, Альтернативы & Customs Reference
Interchange within series: E3Z-G81 (Single axis PNP) ↔ E3Z-G61 (Single axis NPN); E3Z-G82 Dual axis PNP
Отечественная альтернатива: Groove photoelectric sensor, 25mm slot width, PNP output DC24V, response ≤1ms
HS Code Reference: 85414090 (Photosensitive semiconductor device, for customs declaration only, subject to customs final verification)
Если необходимо, I can further provide:
- A4 one-page printable condensed English manual
- Wiring schematic for E3Z-G81 to Siemens PLC sourcing input
Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер