 Устройство защиты от перенапряжения Schneider A9L16482 (СПД) - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

электрический/

Устройство защиты от перенапряжения Schneider A9L16482 (СПД)

Product Basic Positioning Schneider A9L16482 is a Type 1+2 combined surge protection device (СПД) belonging to the Acti9 iPRD1 series, with the full model name Acti9 iPRD1 12.5r 3P+N 350V with remote signal transmission. It is used for primary and secondary overvoltage protection in low-voltage distribution systems, and can simultaneously protect against transient overvoltages caused ...

  • Подробная информация о продукте

Product Basic Positioning

Schneider A9L16482 is a Type 1+2 combined surge protection device (СПД) belonging to the Acti9 iPRD1 series, with the full model name Acti9 iPRD1 12.5r 3P+N 350V with remote signal transmission. It is used for primary and secondary overvoltage protection in low-voltage distribution systems, and can simultaneously protect against transient overvoltages caused by direct and indirect lightning strikes.

  1. Основные технические параметры
Категория параметраDetailed Specifications
Модель продуктаA9L16482 (Acti9 iPRD1 12.5r)
Класс защитыТип 1+2 (Combination of Class I + Class II)
Конфигурация полюсов3П+Н (Three-phase + Neutral), 4-module width
Номинальное напряжение400В и, Максимальное непрерывное рабочее напряжение (УК) 350В и
Максимальный ток разрядаImax=50kA (8/20s waveform), In=20кА (8/20s waveform)
Уровень защиты напряженияUp=1.5kV, 1.5kV for L-N/L-L/N-PE
Protection TechnologyMOV+GDT combined technology (Metal Oxide Varistor + Gas Discharge Tube)
Earthing System CompatibilitySuitable for TN-S and TT systems, not applicable to TN-C, IT, DC systems
Способ монтажаМонтаж на DIN-рейку, Размеры: 89мм(ЧАС)*72мм(Вт)*69мм(Д)
Wiring CapacityRigid conductor 10-35mm虏, Flexible conductor 10-25mm虏
Special FunctionsBuilt-in overcurrent protection circuit breaker (self-protection), remote signal transmission (сигнализация неисправности)
  1. Core Product Features
  2. Integrated Type 1+2 Protection: No need for additional Type 1 SPD configuration; a single device provides two-level protection, simplifying distribution design and installation.
  3. Self-protection Design: Built-in dedicated circuit breaker avoids line short-circuit risks caused by SPD faults, improving system safety.
  4. Remote Monitoring Function: Оснащен “replacement requiredsignal output, which can be connected to Building Automation System (BAS) or distribution monitoring system to realize real-time fault early warning.
  5. Modular Plug-in Design: Damaged pluggable protection modules can be replaced quickly, allowing maintenance without power outage and reducing system downtime.
  6. High-performance Protection: MOV+GDT combined technology provides low residual voltage (1.5кВ) and high current-carrying capacity (50тот) to ensure equipment safety.
  7. Высокая надежность: Соответствует МЭК 61643-11 стандартный, guaranteed by Schneider original quality, with a warranty period of 18-24 месяцы.
  8. Типичные сценарии применения
  9. Incoming Cabinet of Residential and Commercial Buildings: Especially recommended for the main incoming distribution cabinet in high-risk areas as the first-level + second-level surge protection for household access.
  10. Distribution System of Small and Medium-sized Factories: Provides basic surge protection for production lines and precision equipment to prevent key equipment damage caused by lightning strikes.
  11. Data Centers and Computer Rooms: Serves as surge protection for UPS front-end or rack-mounted distribution cabinets, protecting sensitive electronic equipment such as servers and network devices.
  12. Medical Facilities: Provides reliable overvoltage protection for medical equipment, meeting the electrical safety requirements of medical sites.
  13. New Energy Systems: Suitable for grid-connected cabinets of distributed photovoltaic and small wind power systems, protecting core equipment such as inverters.
  14. Installation and Selection Notes
  15. Installation Location: It is recommended to install at the incoming end of the distribution system, close to the main switch, to maximize the protection range.
  16. Cooperative Protection: Although it has a built-in circuit breaker, it is recommended to install a 16-25A miniature circuit breaker at the front end as backup protection to improve selectivity.
  17. Cable Requirements: The connecting cable should be as short as possible (≤50cm), using copper conductors with a cross-sectional area of not less than 16mm² to reduce line impedance.
  18. Earthing Requirements: The PE wire connection must be reliable, and the earthing resistance should comply with relevant specifications (≤4Ω) to ensure rapid discharge of surge current.
  19. Replacement Reminder: When the remote signal alarms or the panel indicator light turns red, the protection module should be replaced in a timely manner to restore the protection function.
  20. Совместимость системы: Only applicable to 400V AC three-phase systems; the maximum continuous operating voltage of 350V ensures stable operation in environments with voltage fluctuations.
  21. Alternative and Complementary Models

Same-series Alternatives: A9L16282 (iPRD1 25r, Imax=100kA), A9L16382 (iPRD1 6.5r, Imax=25kA)

Version without Remote Signal: A9L16480 (iPRD1 12.5, no remote signal)

Upgraded Models: Acti9 iPRD2 series (higher current-carrying capacity, intelligent monitoring function)

Cross-brand Replacement Comparison Table for Schneider A9L16482 Surge Protection Device

Core parameters of Schneider A9L16482: Тип 1+2 combined SPD, 3П+Н, Imax=50kA(8/20μs), Iimp=12.5kA(10/350μs), Uc=350В, Up=1.5kV, with remote signal transmission, MOV+GDT protection technology, drawer-type module, 4-module width(72мм). The following are the corresponding replacement models of major mainstream brands and key matching points:

  1. Core Replacement Model Comparison Table
БрендCorresponding ModelКлючевые параметры соответствияОписание разницы
Шнайдер (Same Series)A9L164803П+Н, T1+T2, 50тот, 350ВA9L16480 without remote signal
A9L162823П+Н, T1+T2, 100тот, 350ВA9L16282 with higher current-carrying capacity
A9L166343П+Н, T1+T2, 50тот, 350ВA9L16634 belongs to iPRF1 series with consistent functions
АББOVR T1-T2 N 50-440s P QS TS3П+Н, T1+T2, 50тот, 350В“ТС” indicates with remote auxiliary contact
OVR T1-T2 3N 12.5-350s P QS TS3П+Н, T1+T2, 50тот, 350ВOVR series is compatible with System pro M compact
Сименс5SD7414-33П+Н, T1+T2, 50тот, 335ВRSC indicates with remote signal contact
5SD74 T1/T2 12.5/50kA 335V 3P+N RSC3П+Н, T1+T2, 50тот, 335В5SD74 series adopts modular design with 4-module width
ЧинтNU5-Ⅰ+Ⅱ-12.5/50 3P+N/F3П+Н, T1+T2, 50тот, 385ВUc=385V (slightly higher than 350V)
NXU-Ⅰ+Ⅱ-12.5/50 3P+N/Y3П+Н, T1+T2, 50тот, 385В/F and /Y indicate with remote signal
NXU series of Kunlun series adopts plug-in design
ВкусныйCDYU-I+II-12.5/50 3P+N/Y3П+Н, T1+T2, 50тот, 385В/Y indicates with remote signal contact
DZ47sY-I+II 50kA 3P+N/Y3П+Н, T1+T2, 50тот, 385ВCDYU series is plug-in type, DZ47sY is rail-mounted type
Феникс КонтактVAL-MS-T1/T2 335/12.5/3+1-FM3П+Н, T1+T2, 50тот, 335ВFM indicates with remote indication contact
FLT-SEC-P-T1-2C-350/25-FM3П+Н, T1+T2, 50тот, 350ВVAL-MS series is dedicated for 5-wire systems (L1-L3,N,ЧП)
Changshu SwitchCHK-I+II-50 3P+N/R3П+Н, T1+T2, 50тот, 385В/R indicates with remote alarm contact
CHK series adopts drawer-type module design
NaderNSPD T1+T2-50 3P+N/Y3П+Н, T1+T2, 50тот, 385В/Y indicates with remote signal
Nader NSPD series has passed CQC certification
  1. Detailed Description of Replacement Models of Various Brands

2.1 ABB Replacement Solution

Preferred Model: OVR T1-T2 3N 12.5-350s P QS TS

Класс защиты: Тип 1+2, meeting both Class I (10/350μs) and Class II (8/20μs) tests

Основные параметры: Imax=50kA, Iimp=12.5kA, Uc=350В, Up=1.5kV, fully matching A9L16482

Установка: 4-module width (72мм), Монтаж на DIN-рейку, plug-in design for convenient maintenance

Remote Function: А “ТС” configuration provides fault alarm contacts that can be connected to the building automation system

2.2 Siemens Replacement Solution

Preferred Model: 5SD7414-3 (5SD74 T1/T2 12.5/50kA 335V 3P+N RSC)

Technical Features: MOV+GDT combined protection, consistent with the technology of Schneider A9L16482

Размеры: 4-module width (72мм), fully compatible with A9L16482 without modifying the cabinet layout

Remote Signal: The RSC version comes standard with remote signal contacts, which automatically close when a fault occurs and can drive indicator lights or alarm systems

Примечание: Uc=335V (slightly lower than 350V), suitable for standard 400V systems, not recommended for occasions with large voltage fluctuations

2.3 Chint Replacement Solution

Preferred Model: NU5-Ⅰ+Ⅱ-12.5/50 3P+N/F (NXU-Ⅰ+Ⅱ-12.5/50 3P+N/Y of Kunlun series)

Особенности конструкции: Integrated T1+T2 protection, no need for additional primary SPD configuration

Ключевые параметры: Imax=50kA, Iimp=12.5kA, Up=1.5kV, meeting the protection requirements of A9L16482

Difference: Uc=385V (slightly higher than 350V), with stronger adaptability, suitable for systems with large voltage fluctuations

Remote Function: The suffixes “/Ф” и “/Да” indicate with remote fault alarm contacts, contact capacity: AC 250V/5A, DC 30V/1A

2.4 Phoenix Contact Replacement Solution

Preferred Model: VAL-MS-T1/T2 335/12.5/3+1-FM (Заказ №.: 2800183)

Technical Advantage: Hot-swappable design, modules can be replaced with power on when a fault occurs, reducing system downtime

Основные параметры: Imax=50kA, Iimp=12.5kA, Uc=335V, Up=1.5kV, consistent with A9L16482

Remote Function: The FM version comes standard with remote indication contacts, whose state changes when a fault occurs, contact type: NO/NC optional

Applicable System: 5-wire system (L1-L3, Н, ЧП), with good compatibility with the TN-S/TT system of A9L16482

  1. Key Replacement Notes
ЭлементTechnical PointsRecommended Practice
Core Parameter MatchingMust ensure:Prioritize models with Uc=350V
Класс защиты: Тип 1+2 (meeting both Class I + Class II tests)Up≤1.5kV ensures consistent protection effect
Current-carrying Capacity: Imax≥50kA, Iimp≥12.5kA
УК: 350V or 385V (suitable for 400V systems)
Вверх: ≤1.5kV (protecting sensitive equipment)
Installation Dimension CompatibilityA9L16482 has a 4-module width (72мм) for DIN rail mountingThe width of the replacement model must be ≤72mm
For drawer-type models, confirm rail compatibility
Remote Signal CompatibilityContact type (NO/NC) and capacity (AC 250V/5A) need to match the original systemCheck the design of the remote alarm circuit
Install a signal conversion module if necessary
Protection Technology MatchingA9L16482 adopts MOV+GDT combined technologyPrioritize products with the same technical route
Pure MOV type requires additional backup protection
Совместимость системыOnly applicable to TN-S and TT systems, not applicable to TN-C, IT systemsConfirm the earthing system type before replacement
Adjust the SPD wiring method if necessary
Backup Protection CoordinationA9L16482 has a built-in dedicated circuit breakerFor models without built-in protection, backup protection must be installed at the front end
Some brands need additional 16-25A miniature circuit breakersEnsure protection selectivity
  1. Recommended Replacement Solutions
  2. Same-brand Replacement: Schneider A9L16480 (without remote signal) or A9L16634 (iPRF1 series), fully compatible without adjusting the installation space and control system
  3. International Brand Upgrade: ABB OVR T1-T2 3N 12.5-350s P QS TS or Siemens 5SD7414-3, with reliable quality and complete remote functions, suitable for important projects
  4. Cost-effective Domestic Alternative: Chint NU5-Ⅰ+Ⅱ-12.5/50 3P+N/F or Delixi CDYU-I+II-12.5/50 3P+N/Y, priced at about 60%-70% of international brands, with performance meeting requirements
  5. Technology Upgrade Solution: Phoenix Contact VAL-MS-T1/T2 335/12.5/3+1-FM, with plug-in design for more convenient maintenance and more complete remote monitoring functions, suitable for key scenarios such as data centers
  6. Quick Selection Suggestions
  7. General Projects: Choose domestic alternatives (Chint/Delixi) for the highest cost performance and satisfactory performance
  8. Important Projects: Choose products of the same series from ABB/Siemens/Schneider for higher reliability and complete remote functions
  9. Maintenance Convenience Priority: Choose plug-in design (such as Phoenix Contact VAL-MS series, ABB OVR series) for quick module replacement in case of faults and reduced downtime