3‑pole contactor from domestic TeSys Giga series, AC‑3 475A/440V, coil 100–250V AC/DC wide voltage, стандартные вспомогательные контакты 1НО+1НЗ. Suitable for high‑power motor control and power switching. Supports contact wear diagnosis and can be used with LR9G series thermal relays.
1 Основные параметры & Naming Explanation
| Элемент | Спецификация | Описание |
| Модель | LC1G475KUEC | Domestic TeSys Giga series, 3П(3НЕТ), AC‑3 ≤440V 475A, 100–250V AC/DC coil |
| Ряд | TeSys Giga (LC1G) | New generation high‑power contactor from Schneider, replaces old LC1D475 |
| Poles | 3П(3НЕТ) | 3‑pole normally open, for three‑phase circuit control |
| Номинальный ток | 475А (AC‑3, ≤440V) | Rated operational current of main circuit |
| Coil voltage | 100–250V AC/DC | Wide‑voltage design, compatible with various control supplies |
| Coil frequency | 50/60Гц | Compatible with global mains frequencies |
| Auxiliary contacts | 1НО+1НЗ | Standard configuration, expandable with more aux contacts |
| Applicable standards | IEC 60947‑4‑1, ГБ/Т 14048.4 | Complies with international and national standards |
| Version | China version (suffix C) | Designed for domestic market; no UL certification; global version without C |
2 Key Performance Data
| Utilization category | Rated power (400В) | Rated power (440В) | Short‑time withstand current |
| AC‑3 (normal motor starting/running) | приблизительно. 250кВт | приблизительно. 265кВт | 10500А (1с) |
| AC‑4 (frequent starting/reversing) | приблизительно. 180кВт | приблизительно. 190кВт | – |
| AC‑1 (резистивная нагрузка) | приблизительно. 475кВт | приблизительно. 475кВт | – |
3 Applications & Функции
Applications
Direct starting, forward/reverse control, star‑delta starting of high‑power three‑phase asynchronous motors
Industrial power switching and distribution system control
Inductive load control with power factor ≥ 0.95
Heavy‑duty industries: building electrical, metallurgy, chemical, mining, и т. д..
Key Features
- High performance: Up to 620A at AC‑3, 1050A at AC‑1 for heavy‑duty applications
- Smart diagnosis: Built‑in contact wear detection for predictive maintenance
- Wide‑voltage coil: 100–250V AC/DC reduces spare parts inventory
- Модульная конструкция: Supports various accessories (aux contacts, mechanical interlock, surge suppressor, и т. д.)
- Safe & reliable: Excellent arc extinguishing, suitable for harsh industrial environments
4 Mounting & Wiring Information
Mounting dimensions (China version LC1G475C)
Ширина: приблизительно. 140мм
Height: приблизительно. 270мм
Depth: приблизительно. 150мм
Mounting: Standard 35mm DIN rail or screw mounting
Масса: приблизительно. 10.6кг
Wiring requirements
- Main circuit terminals: Suitable for copper/aluminum cables; crimping lugs recommended
- Control circuit terminals: Suitable for 1.5–2.5mm² control cables
- Clearance: ≥50mm left & right, ≥100mm top & bottom for proper heat dissipation
5 Accessory Compatibility & Matching Products
| Accessory type | Recommended model | Функция |
| Thermal overload relay | LR9G475 | Matches LC1G475KUEC, provides motor overload protection |
| Mechanical interlock | For LC1G series | For forward/reverse control; prevents simultaneous closing |
| Surge suppressor | For LC1G series | Protects coil against voltage spikes |
| Auxiliary contact module | For LC1G series | Expands NO/NC contacts for complex control |
6 Cross‑Brand Alternatives
| Бренд | Replacement model | Match level | Примечания |
| АББ | AF460‑30‑11 (100–250V AC/DC) | Высокий | Rated 460A, close to 475A; verify load margin |
| Сименс | 3RT2076‑6AP36 (100–250V AC/DC) | Высокий | Sirius series, 475А, fully compatible |
| Чинт | CJX1‑475/22 (100–250V AC/DC) | Medium | Domestic alternative; slight performance differences, cost‑effective |
| Changshu Switch | CK3‑475 (100–250V AC/DC) | Medium | Premium domestic brand, high cost‑performance |
7 Установка & Commissioning Tips
- Pre‑installation inspection
Verify model, rated parameters and control supply match
Check for physical damage, contact oxidation
Ensure flat mounting surface and secure rail
- Installation steps
DIN rail: Align to 35mm rail, press firmly until locked
Screw mounting: Use M6 screws, torque 8–10N·m
Электропроводка: Main circuit first, then control circuit; observe terminal torque
- Commissioning & testing
No‑load test: Apply control power; check smooth operation, abnormal noise
Load test: Run under load; monitor current, coil temperature
Aux contact test: Verify NO/NC switching and contact resistance
- Maintenance recommendations
Regularly inspect contact wear; replace if wear >1мм
Clean arc chamber; remove dust and metal particles
Check coil insulation resistance ≥1MΩ
Retighten all terminals to avoid overheating
8 Selection Notes
- Select contactor according to load type (AC‑3/AC‑4/AC‑1)
- For motor control: Contactor rated current ≥ 1.1 × motor rated current
- For frequent starting/reversing (AC‑4): Derate by 20–30%
- For unstable control supply: Prefer wide‑voltage coil models
- When used with thermal relay: Ensure matching ratings
Installation Manual – Schneider Domestic TeSys LC1G475KUEC 3‑Pole Contactor
Doc No.: DOCA0189ZH‑04 (based on official Schneider TeSys Giga installation guide)
Applicable model: LC1G475KUEC (domestic TeSys Giga 3‑pole contactor)
Version: January 2023
⚠️ Safety Warnings (Must Read)
| Hazard type | Preventive measures |
| Electric shock / explosion / arc flash hazard | 1. Disconnect all power (main and control) before installation |
| 2. Only qualified electricians may operate | |
| 3. Use appropriate PPE | |
| 4. Comply with electrical safety codes (например, NFPA 70E) | |
| 5. Install in non‑hazardous areas (МЭК 60079) | |
| Mechanical injury hazard | 1. Contactor approx. 10.6кг; support during installation |
| 2. Avoid finger pinching between contactor and mounting plate/rail | |
| 3. Use proper tools to prevent slipping injury | |
| Overheating hazard | 1. Maintain required clearances: ≥50mm sides, ≥100mm top/bottom |
| 2. Do not store flammables near contactor | |
| 3. Inspect cooling regularly |
1 Product Overview
1.1 Product Identification
Модель: LC1G475KUEC
Ряд: Domestic TeSys Giga (LC1G)
Poles: 3П (3НЕТ, 3‑pole normally open)
Номинальный ток: AC‑3 475A (440В)
Coil voltage: 100–250V AC/DC (wide voltage)
Auxiliary contacts: 1NO+1NC standard
Standards: IEC 60947‑4‑1, ГБ/Т 14048.4
Version: China version (suffix C; no UL certification)
1.2 Размеры (Unit: мм)
| Dimension | Ценить |
| Ширина | 140 |
| Height | 270 |
| Depth | 150 |
| Mounting hole spacing | 100×120 (bottom hanging + fixing holes) |
2 Pre‑Installation Preparation
2.1 Tools
крестовая отвертка (PH3)
Hex key (per fixing screw size)
Torque wrench (5–20N·m range)
Wire stripper (1.5–2.5mm² control & large main cables)
Crimping tool (for cable lugs)
Multimeter (coil resistance & insulation check)
Spirit level
2.2 Materials
Mounting plate (metal, thickness ≥3mm, flat, burr‑free)
M6 mounting screws (min. 4 pcs)
Cable lugs (for main circuit cables)
Control cable (1.5–2.5mm² copper)
Main cable (≥150mm² copper recommended)
Insulation tape / heat‑shrink tubing
Marker pen
2.3 Экологические требования
| Параметр | Requirement |
| Температура | -5°С ~ +40°С (operating); -25°C ~ +55°C (storage) |
| Влажность | ≤95% (non‑condensing) |
| Высота | ≤2000m (derate above) |
| Степень загрязнения | 2 (industrial environment) |
| Vibration | ≤5.9m/s² (5–150Hz) |
| Inclination | ≤30° from vertical |
2.4 Product Inspection
- Check packaging and transport damage
- Verify model label (LC1G475KUEC)
- Inspect contacts for oxidation, pitting, foreign matter
- Manually actuate armature; check smooth operation
- Measure coil resistance with multimeter
- Test auxiliary contact switching
3 Installation Procedure (Surface Mounting)
Примечание: Domestic LC1G475KUEC supports surface mounting only; not for DIN rail.
3.1 Mounting Plate Drilling (Необязательный)
- Mark holes at 100×120mm
- Drill diameter: φ6.5mm (for M6)
- Deburr after drilling
3.2 Hanging & Fixing
- Hang: Locate bottom hanging holes onto mounting plate pins/screws
- Preliminary fix: Hand‑tighten top M6 screws
- Final fix: Torque all 4 screws to 3±0.3N·m (top‑down, diagonal)
- Level check: Ensure inclination ≤30°
3.3 Accessory Installation (Aux Contacts / Механическая блокировка)
- Auxiliary contacts
Disconnect control power
Align and push into top slot until click
Verify secure locking
- Mechanical interlock
Keep ≥50mm between two contactors
Mount interlock on sides
Adjust to prevent simultaneous closing
Test manually
4 Wiring Procedure
4.1 Pre‑Wiring Notes
- Confirm all power disconnected
- Main cables must use proper crimp lugs
- Control cable strip length: ~8–10mm
- Sequence: Main circuit first, then control
4.2 Main Circuit Wiring (3П, L1/L2/L3 → T1/T2/T3)
- Open main terminal cover
- Insert lugged cables
- Torque:
Copper: 12±1N·m
Aluminum: 14±1N·m (with anti‑oxidant)
- Securely tighten; check by gentle pull
- Close terminal cover
4.3 Control Circuit Wiring (Coil A1/A2, Aux NO/NC)
- Open control terminal cover
- Катушка:
A1: Control supply +/Line
A2: Control supply –/Neutral
- Aux contacts:
НЕТ: 13–14 (проведение, indication)
Северная Каролина: 21–22 (interlock, fault)
- Control terminal torque: 2±0.2N·m
- Close cover
4.4 Wiring Diagram
5 Mounting with Thermal Relay (LR9G475)
5.1 Direct Installation
- Confirm matching: LC1G475KUEC + LR9G475
- Align thermal relay to top slot
- Push down until click
- Check secure mounting
- Connect pre‑installed busbars
- Torque busbar screws: 8±0.8N·m
5.2 Wiring Notes
- Main: Power → Contactor → Thermal relay → Motor
- Control: Thermal relay NC (95–96) in series with contactor coil
- Set thermal relay current to motor rated current
6 Commissioning & Тестирование
6.1 No‑Load Test
- Apply control power (main open)
- Check smooth closing, no abnormal noise
- Verify aux contact switching
- Check rapid opening
- Repeat 3–5 times
6.2 Нагрузочный тест
- Apply main power
- Start motor; check current within rating
- Monitor coil temperature ≤60°C after 1h
- Check terminal temperature ≤70°C (infrared)
- Simulate overload; verify relay trip
6.3 Contact Wear Diagnosis (LC1G Feature)
- Monitor via auxiliary contacts
- Warning when wear >1мм
- Replace contactor promptly
7 Maintenance & Service
7.1 Routine Inspection (every 6 месяцы)
- De‑energize; inspect for dirt, damage
- Clean arc chamber (compressed air ≤0.3MPa)
- Check contact resistance ≤500μΩ
- Check coil insulation ≥1MΩ (500V megger)
- Retighten terminals
- Test operation
7.2 Replacement Schedule
| Part | Interval | Replacement standard |
| Main contacts | 1–2 years | Wear >1mm or resistance >500μΩ |
| Aux contacts | 2–3 years | Poor switching |
| Катушка | 3–5 years | Insulation aging, weak closing |
| Arc chamber | 5 годы | Degraded performance |
7.3 Поиск неисправностей
| Symptom | Possible causes | Solution |
| Contactor fails to close | 1. No control power | 1. Check wiring |
| 2. Coil fault | 2. Replace coil | |
| 3. Mechanical jam | 3. Clean & lubricate | |
| Loud noise on closing | 1. Dirty iron core | 1. Clean surfaces |
| 2. Broken ring | 2. Replace ring | |
| 3. Низкое напряжение катушки | 3. Check supply | |
| Contacts overheating | 1. Loose terminals | 1. Retighten |
| 2. Oxidized contacts | 2. Clean/replace contacts | |
| 3. Перегрузка | 3. Check load | |
| Slow opening | 1. Fatigued spring | 1. Replace spring |
| 2. Mechanical jam | 2. Clean mechanism | |
| 3. Residual magnetism | 3. Check coil |
8 Безопасность & Среда
8.1 Safe Disposal
- Disconnect all power before scrapping
- Remove all wiring
- Separate metal & plastic for recycling
- Contacts contain silver alloy; recycle as precious metal
8.2 Environmental Compliance
RoHS compliant; free of Pb, Hg, и т. д..
Plastic housing recyclable
Dispose per local regulations
9 Appendix – Technical Data
| Параметр | Ценить |
| Rated operational current (AC‑3, 400В) | 475А |
| Rated power (400В, AC‑3) | 250кВт |
| Short‑time withstand current (1с) | 10500А |
| Coil voltage | 100–250V AC/DC |
| Coil power | Inrush: ~200VA, Sealed: ~20W |
| Aux contact rated current | 5А (AC‑15, 220В) |
| Mechanical life | 10,000,000 операции |
| Electrical life (AC‑3) | 1,000,000 операции |
Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи


















NH42-63-318x560.png)