Позиционирование: Modicon M221 series compact integrated PLC, 24В постоянного тока источник питания, 40-point I/O, PNP-транзисторный выход, built-in Ethernet port
✅ Определение кода модели
TM221: Modicon M221 series compact PLC
С: Integrated controller body
Э: Встроенный Ethernet
40: Общий 40 Точки ввода-вывода
Т: Транзисторный выход (Тип ПНП, suitable for servo/stepper drive)
📋 Core I/O Specifications
Источник питания: 24 В постоянного тока (20.4~28.8V)
Цифровой вход: 24 points DC24V, source/sink compatible; 4 high-speed inputs
Цифровой выход: 16 points PNP transistor DC24V, Макс. 0.5на канал; 2 high-speed pulse outputs (for stepper/servo drive)
Built-in analog input: 2AI 0~10V, 10-bit resolution
Всего ввода-вывода: 40 on-board I/O points, expandable with TM3 series modules
Local expansion: до 7 TM3 modules
Remote expansion: до 14 TM3 modules
📶 Communication Interfaces
- Ethernet Port: Модбус TCP, connectable to HMI, СКАДА, частотно-регулируемые приводы
- Serial port RS232/RS485: Модбус РТУ
- Mini-USB: Загрузка программы & отладка
- Слот для SD-карты: Program backup, обновление прошивки, регистрация данных
- On-board Run/Stop toggle switch; BR2032 battery for retentive registers
⚙️ Electrical & Механические данные
No-load power consumption: 4.9Вт; Макс. 17W with full expansion modules
Expansion bus power supply: 5V/0.52A; 24V/0.3A
Монтаж: Крепление на DIN-рейку; Removable screw terminals
Программное обеспечение для программирования: EcoStruxure Machine Expert Basic (formerly SoMachine Basic), compliant with IEC61131-3 (ЛД, СТ, ФБД, и т. д.)
🎯 Typical Applications
Small standalone автоматизация: упаковочное оборудование, конвейерные линии, injection molding auxiliary equipment, небольшие станки, Шкафы управления ОВиК, applications requiring pulse servo control plus Ethernet networking.
Selection note: sibling model TM221CE40R is relay output, no high-speed pulse support, for ordinary contactor loads only.
🧩 Accessories & Варианты замены
- Expansion modules: TM3DI, TM3DO, TM3AI, TM3AQ digital/analog modules
- Spare parts: BR2032 battery, SD card, TM3 terminal blocks
- Performance upgrade alternative: М241 (более высокая производительность, more communication interfaces); Замена той же серии: ТМ221CE40R (relay version)
- Legacy model replacement: Replaces TWIDO series TWDLCAE40DRF
⚠️ General Notes & Поиск неисправностей
- PNP-транзисторный выход: Only for DC24V loads, AC loads are prohibited; Short circuit on output points will easily burn the channel
- High-speed pulse: Только 2 on-board high-speed outputs, limited pulse frequency. External pulse module recommended for high-power servo
- Ethernet: Early firmware versions have occasional disconnection issues; firmware upgrade recommended; shielded cable preferred
- Батарея: Only retains retentive registers, program stored in Flash, program will not be lost after power failure; Flat battery only causes loss of retentive variables
- Терминалы: Power off before disassembly; Shielded cable for analog input to reduce interference
📌 Selection Comparison Table
| Модель | ввод/вывод | Тип выхода | Ethernet | Импульсный выход |
| TM221CE40T | 40 | PNP Transistor | Да | 2-channel high-speed pulse |
| ТМ221CE40R | 40 | Реле | Да | Никто |
EcoStruxure Machine Expert Basic (formerly SoMachine Basic) Program Migration Guidelines
Applicable to TM221CE40T. Four migration scenarios: ① Old SoMachine Basic project → EcoStruxure Machine Expert Basic; ② Legacy Twido program → M221; ③ Program clone/download between identical M221 PLCs; ④ Cross-hardware M221 migration (например. TM221CE40R to TM221CE40T)
- Software Version Migration (.smbp Project Upgrade)
- File Compatibility: EcoStruxure Machine Expert Basic can directly open `.smbp` projects from SoMachine Basic with automatic conversion, no manual script conversion required. Conversion report will be generated after opening; prioritize warnings and errors in the report.
- Version Recommendation
Upgrade old SoMachine Basic to v1.6 SP2 or higher before migration. Projects from older versions risk loss of variables and communication macros during conversion.
Software version ≥ firmware version. PLC firmware must be upgraded to match software version, otherwise download will report firmware incompatibility.
- Post-conversion Checklist
Variable table: Check retentive variables, system words %SW, system bits %S mapping; some legacy macro variables will be renamed.
Communication macros: Modbus RTU/TCP macros, some legacy macros will be replaced by new library components, parameters need re-verification.
Program editor: LD ladder and ST structured text are mostly lossless; a small number of legacy FBD blocks will trigger warnings.
- Migrate Legacy Twido (TWIDO) Program to TM221CE40T (Key Section)
Твидо (TWDLCAE40DRF) migration workflow: TwidoSuite → export `.xpr/.xar/.twd` → open & import directly in EcoStruxure Machine Expert Basic
⚠️ Twido program cannot be downloaded directly into M221; software conversion is mandatory.
Frequent Pitfalls for Twido Migration
- I/O address mapping difference: Twido and M221 use different I/O address systems. I/O allocation must be fully rechecked after conversion, especially analog channels.
- Последовательная связь: Twido serial port parameters and Modbus timing differ from M221 RS485/RS232. Скорость передачи данных, parity and slave address need reconfiguration; communication macros require manual correction, imported macros cannot run directly.
- Высокоскоростной импульс (ВОМ): Twido pulse instructions are not fully compatible with M221 PTO function blocks, this is the most critical point for TM221CE40T migration:
M221 CPU only has 2 on-board PTO pulse outputs;
Pulse frequency, acceleration/deceleration, homing and limit logic must be retested after migration; legacy Twido pulse macros will be replaced and some parameters lost.
- System Words %SW: Twido system registers have different definitions compared with M221 %SW, do not reuse directly.
- Timer/Counter: Difference in resolution and refresh cycle; power-down and retentive behavior need validation.
- M221 Intra-platform Migration (Same Model / Different M221 CPU)
Scenario A: Download Project from PC to TM221CE40T
- Конфигурация оборудования: Controller model in project must be set to `TM221CE40T`; If original project is for TM221CE40R, switching model will trigger PTO block errors (relay CPU has no high-speed output hardware). Either remove pulse logic or change target hardware.
- Expansion modules: TM3 module configuration, module sequence and model must match physical hardware on site, or PLC will report hardware mismatch fault.
- Download channels: MiniUSB, Ethernet, SD card image download.
Upload restriction: If read protection is enabled on original project, program upload from PLC is blocked; only SD card recovery works.
Scenario B: SD Card Clone Migration (Batch Program Copy including Firmware)
For batch replication on multiple identical TM221CE40T units
- SD card requirement: FAT32 formatted, card name must NOT be DATA (DATA reserved for data logging).
- Two operation modes:
Mode1: Power PLC to STOP state, insert SD card; PLC automatically clones program + firmware to SD card; cloning is slow under RUN status.
Mode2: Create Controller Image in software on PC, write image file to SD card, firmware can be bundled optionally.
- SD card restore procedure: Power off and insert card → power on for automatic flashing → SD LED off → power off, remove card and restart PLC.
Важный: SD clone erases existing program in target PLC; fault logs and real-time variables will NOT be cloned. Password-protected programs cannot be cloned.
- PTO Motion Program Migration (TM221CE40T Exclusive Focus)
2 on-board high-speed pulses are core feature of this transistor model; migration errors will lead to servo failure:
- After migration of legacy pulse logic, проверять: Pulse output addresses %PTO0, %PTO1; pulse mode (Пульс+Направление / Dual-pulse).
- Pulse parameters: Max frequency, acceleration/deceleration, soft limit, home signal; parameters are prone to missing after migration and must be reconfirmed.
- Аппаратное обеспечение: ПНП-выход, AC loads forbidden on external wiring; short circuit prohibited on pulse terminals.
- Ограничение: M221 on-board PTO only supports point-to-point positioning, no multi-axis interpolation. If legacy logic contains multi-axis interpolation, M221 cannot fulfill it; M241 is required instead.
- Communication Program Migration (Модбус TCP / Модбус РТУ)
- Модбус TCP: M221 built-in Ethernet, IP address, subnet mask and gateway are stored independently in PLC hardware configuration, not in project variables. Downloading project will overwrite PLC IP with project configured value, site original IP will be lost.
- Модбус РТУ (RS485):
Serial terminals and hardware flow control differ from Twido;
For Modbus read/write blocks imported from legacy project, increase timeout and inter-frame gap to mitigate communication loss caused by interference.
- HMI integration: Export `.smpb` variable file for Vijeo Designer variable linking; Watch Big/Little-Endian order for double words, this is the most common issue for HMI/SCADA communication.
- Variable & Power-down Retention Migration
- Retentive variables: Program stored in Flash, no loss after power cycle; retentive registers maintained by on-board BR2032 battery. Dead battery only loses retentive variables, program remains intact.
- Pre-migration: Export variable table and compare after migration; confirm which variables are marked retentive.
- Application protection: Read/write protection in project properties. Once read protection enabled, program upload from PLC is impossible; SD card image recovery only. Blank password locks software connection, SD card flashing required to clear protection.
- Standard Migration Test Procedure
- Compile: Zero errors, resolve warnings (коммуникация, ВОМ, system word warnings prioritized).
- Оффлайн моделирование: Run logic in EcoStruxure Machine Expert Basic built-in simulator first.
- Before hardware download: Switch PLC to STOP; backup original PLC program (SD clone preferred).
- Скачать: After download, verify hardware configuration, confirm all TM3 modules are recognized normally.
- Stepwise test: I/O point test → Modbus communication → PTO pulse/servo positioning → Power-down retention test.
- Long-term stability: Upgrade PLC firmware to stable release to fix known occasional Ethernet disconnection bug in old firmware.
- Common Migration Fault List
| Симптом | Первопричина | Решение |
| Скачать: Hardware mismatch | Project PLC model inconsistent with physical unit, or TM3 module configuration mismatch | Change controller model in project, verify TM3 module list |
| PTO function block error | Target PLC is relay output type (ТМ221CE40R), no PTO hardware | Replace hardware with TM221CE40T or remove redundant PTO logic |
| Cannot upload program | Read protection enabled in project | Recover program via SD card image |
| Unstable Modbus communication | Incorrect serial parameters, inter-frame gap, missing termination resistor; Twido timing incompatibility | Adjust communication timeout, check shield cable and termination resistor |
| SD card clone failed | SD not FAT32, volume name DATA, password protected program | Replace SD card, remove project protection before cloning |
Deliverables Before & After Migration
- Pre-migration: Original project backup, PLC program upload backup, SD full image, I/O list, variable table, communication parameter sheet, servo parameters.
- Post-migration: Conversion report, new source project, exported variable list, test log, firmware version record.
Optional items I can provide separately:
- Twido to M221 PTO sample code (ST or LD)
- Full I/O and %SW system register list for TM221CE40T
- SD card clone operation document for field engineers
Модикон М221 (TM221) Full CPU Model List
Определение кода модели
TM221C: Standard integrated CPU; E = Built-in Ethernet; No E = Without Ethernet
Число: Всего точек ввода-вывода (16/24/40)
Р: Релейный выход; Т: PNP transistor (supports PTO high-speed pulse); ты: NPN transistor
TM221M: Book-style slim M221, side DIN rail mount; ME = with Ethernet
All C/M CPUs come with 2 built-in AI 0~10V, 10-кусочек
- Standard Integrated TM221C (Without Ethernet)
| Модель | Всего ввода-вывода | ОТ | ДЕЛАТЬ | Тип выхода | Источник питания | Примечания |
| TM221C16R | 16 | 9 | 7 | Реле | AC100~240V | No pulse |
| TM221C16T | 16 | 9 | 7 | PNP Transistor | 24 В постоянного тока | 2ch PTO |
| TM221C16U | 16 | 9 | 7 | NPN-транзистор | 24 В постоянного тока | 2ch PTO |
| TM221C24R | 24 | 14 | 10 | Реле | AC100~240V | No pulse |
| TM221C24T | 24 | 14 | 10 | PNP Transistor | 24 В постоянного тока | 2ch PTO |
| TM221C24U | 24 | 14 | 10 | NPN-транзистор | 24 В постоянного тока | 2ch PTO |
| TM221C40R | 40 | 24 | 16 | Реле | AC100~240V | No pulse |
| TM221C40T | 40 | 24 | 16 | PNP Transistor | 24 В постоянного тока | 2ch PTO, non-Ethernet version of your model |
| TM221C40U | 40 | 24 | 16 | NPN-транзистор | 24 В постоянного тока | 2ch PTO |
- Standard Integrated TM221CE (Встроенный Ethernet, TM221CE40T belongs here)
| Модель | Всего ввода-вывода | ОТ | ДЕЛАТЬ | Тип выхода | Источник питания | Примечания |
| TM221CE16R | 16 | 9 | 7 | Реле | AC100~240V | No pulse, Модбус TCP |
| TM221CE16T | 16 | 9 | 7 | PNP Transistor | 24 В постоянного тока | 2ch PTO |
| TM221CE16U | 16 | 9 | 7 | NPN-транзистор | 24 В постоянного тока | 2ch PTO |
| ТМ221CE24R | 24 | 14 | 10 | Реле | AC100~240V | No pulse |
| TM221CE24T | 24 | 14 | 10 | PNP Transistor | 24 В постоянного тока | 2ch PTO |
| TM221CE24U | 24 | 14 | 10 | NPN-транзистор | 24 В постоянного тока | 2ch PTO |
| ТМ221CE40R | 40 | 24 | 16 | Реле | AC100~240V | No pulse |
| TM221CE40T | 40 | 24 | 16 | PNP Transistor | 24 В постоянного тока | 2ch PTO, popular servo model |
| TM221CE40U | 40 | 24 | 16 | NPN-транзистор | 24 В постоянного тока | 2ch PTO |
- Book-style TM221M / TM221ME (Slim compact, side DIN rail)
| Модель | Всего ввода-вывода | ОТ | ДЕЛАТЬ | Тип выхода | Источник питания | Примечания |
| TM221M16R | 16 | 9 | 7 | Реле | AC100~240V | Нет Ethernet |
| TM221M16T | 16 | 9 | 7 | PNP Transistor | 24 В постоянного тока | Нет Ethernet, 2ch PTO |
| TM221M16U | 16 | 9 | 7 | NPN-транзистор | 24 В постоянного тока | Нет Ethernet, 2ch PTO |
| TM221ME16R | 16 | 9 | 7 | Реле | AC100~240V | С Ethernet |
| TM221ME16T | 16 | 9 | 7 | PNP Transistor | 24 В постоянного тока | С Ethernet, 2ch PTO |
| TM221ME16U | 16 | 9 | 7 | NPN-транзистор | 24 В постоянного тока | С Ethernet, 2ch PTO |
| TM221M32TK | 32 | 18 | 14 | PNP Transistor | 24 В постоянного тока | Нет Ethernet, 4 high-speed pulse |
| TM221ME32TK | 32 | 18 | 14 | PNP Transistor | 24 В постоянного тока | С Ethernet, Only M221 CPU with 4 on-board pulse axes |
- M221 Compatible TM3 Expansion Modules (Works for all M221 CPUs)
Max.7 TM3 local modules; Max.14 TM3 remote bus modules
- Цифровой вход: TM3DI8, TM3DI16
- Цифровой выход: TM3DO8R, ТМ3ДО8Т, TM3DO16T
- Смешанный ввод-вывод: TM3DM8R, TM3DM24R
- Аналоговый: TM3AI2H, TM3AI4, TM3AQ2, TM3AQ4
- RTD/Thermocouple: TM3TI2, TM3TI4
- Communication module: TM3RS485BD (serial expansion board)
- M221 Optional Accessories
Батарея: BR2032 (for retentive registers)
SD Card: Schneider dedicated SD card (program image backup, обновление прошивки)
Special function plug-in card: TMC2PACK01 packaging card / TMC2HOIS01 hoist dedicated card
Терминалы, cover, DIN rail clips
- Quick Selection Guidelines
- Servo/stepper pulse required: Suffix T/U; R relay models have no PTO hardware, cannot drive pulse-type servo drives
- Ethernet networking required: CE / ME models; С / M no Ethernet
- 4-axis pulse requirement: Only TM221ME32TK / TM221M32TK, all other M221 CPUs support maximum 2 PTO channels
- Выходная полярность: T=PNP (most common for domestic DC24V servo, TM221CE40T is this type); U=NPN