Модель Объяснение
XB2-BA31C (Complete ordering model; суффикс “С” cannot be omitted)
ХВ2: Harmony XB2, 22 мм metal pushbutton series
BA: Flush head, spring return pushbutton
3: Зеленый
1: 1 Normally Open contact (1НЕТ)
Component breakdown: ZB2BA3C (pushbutton head) + ZB2BZ101C (1NO contact block)
- Основные технические характеристики
| Элемент | Параметр |
| Mounting cutout diameter | Φ22 mm standard panel cutout |
| Operation type | Spring return (momentary, automatically rebounds upon release) |
| Pushbutton colour | Зеленый (standard start pushbutton) |
| Конфигурация контактов | 1НЕТ (Нормально открытый, терминалы 3-4) |
| Bezel material | Chrome-plated metal, impact-resistant |
| Protection rating | IP65 (front panel side) |
| Rated thermal current | 10 А, rated insulation voltage Ui = 600 В |
| Механическая выносливость | ≥ 3 миллион операций |
| Рабочая температура | -25 ℃ ~ +55 ℃ |
| Тип проводки | Screw terminal connection |
- Типичные применения
Start pushbutton for industrial control cabinets: запуск двигателя, equipment operation triggering, jog control circuits.
Matching reference: Red stop pushbutton XB2-BA42C (1Северная Каролина)
- Common Flush Pushbuttons of the Same Series
XB2-BA11C: Белый, 1НЕТ
XB2-BA21C: Черный, 1НЕТ
XB2-BA31C: Зеленый, 1НЕТ (эта модель)
XB2-BA41C: Красный, 1НЕТ; XB2-BA42C: Красный, 1Северная Каролина
XB2-BA51C: Желтый, 1НЕТ
XB2-BA61C: Синий, 1НЕТ
- Примечания по установке
- Applicable panel thickness: 1~6 mm
- Recommended tightening torque for mounting nut: 0.8 Н·м
- For additional contacts, stack ZB2-BE101 (НЕТ) / ZB2-BE102 (Северная Каролина) contact modules
- This model has no built-in indicator light; for illuminated green start pushbutton, select XB2BW33C series
Complete Installation Procedure for Шнайдер XB2-BA31C (XB2-BA31)
Component composition: ZB2BA3C (green flush pushbutton head) + ZB2BZ101C (1NO contact block)
Preconditions & Инструменты
- Требования к панели
Standard cutout: Φ22 mm, deburred cutout without sharp edges
Applicable panel thickness: 1~6 mm
Minimum centre spacing between adjacent pushbuttons: ≥ 30 мм
- Необходимые инструменты
Flat screwdriver (PH1), инструмент для зачистки проводов; torque screwdriver recommended
- Official Standard Torque Values
Pushbutton mounting nut: 0.8 Н·м (Do NOT over-tighten)
Terminal screws: 0.5~0.8 N·m
- Спецификация кабеля
Recommended 0.5~1.5 mm² stranded copper control cable, stripping length 7~10 mm
Step-by-Step Standard Installation Sequence
⚠️ First step for all electrical work: Cut off main power supply of control cabinet, implement lockout & tagout!
Шаг 1: Parts Inventory & Визуальный осмотр
Check complete set after unpacking:
- Green pushbutton operating head ZB2BA3C (equipped with sealing gasket to ensure IP65 protection)
- Metal locking nut
- Contact block ZB2BZ101C (1НЕТ)
Verify sealing gasket intact and plastic latches free from cracks.
Шаг 2: Insert Pushbutton Head into Control Panel (Install from FRONT of panel)
- Fit sealing gasket properly onto the rear shoulder of pushbutton head (gasket cannot be omitted or twisted)
- Insert pushbutton head into Φ22 mm cutout from outer (передний) side of panel
- Threaded shank extends out from rear panel; keep pushbutton head closely attached to panel surface without tilt
Шаг 3: Mount locking nut to secure pushbutton head
- Screw metal locking nut onto threaded shank from rear side, hand-tight until touching panel
- Tighten evenly with tool, maintain torque at 0.8 Н·м
✅ Acceptance criteria: Pushbutton free of wobble, smooth pressing without jamming
❌ Do not apply excessive force! Over-tightening will crack sealing gasket, cause pushbutton seizure and void IP65 protection.
Шаг 4: Snap-fit contact block (Most frequent assembly error point)
- Two elastic latches on contact block front side align with slots on rear of pushbutton head
- Push contact block horizontally and straightly; two audible “щелкнуть” sounds confirm full engagement of both latches
❗ Do not pry diagonally or force press violently; broken latches require replacement of contact block
✅ Removal method: Pry both side latches gently with flat screwdriver and pull contact block backward
Шаг 5: Монтаж проводки (XB2-BA31, 1NO contact)
Terminal marking printed on contact block:
Терминалы 3, 4 = Нормально открытый (НЕТ): Open circuit at rest, closed when pressed
- Strip cable insulation, prevent loose copper strands and burrs
- Insert conductor into terminal hole; ensure insulation is not clamped under screw
- Tighten terminal screw clockwise (torque 0.5~0.8 N·m)
- Light traction test on cable to confirm no looseness; exposed copper strands may lead to short circuit risk
Шаг 6: Mechanical test before power-on (Mandatory procedure)
- Press pushbutton repeatedly: smooth operation, instant automatic rebound after release, no sticking or abnormal noise
- Visually confirm contact block latches fully locked to avoid detachment under vibration
- Check sealing gasket fits panel evenly without gaps (critical for dust & water resistance)
Шаг 7: Continuity test before energization
Use multimeter continuity mode to test terminals 3 и 4:
Rest state: Открытая цепь (infinite resistance)
Push and hold pushbutton: Conductive (resistance close to 0 Ой)
Only proceed to switch on power after passing test.
Typical Wiring Reference (Standard Start Circuit)
Control power supply → Terminal 3
Терминал 4 → Contactor coil / PLC digital input
Push button pressed → Terminals 3-4 руководить, start signal triggered
Common Installation Mistakes & Warnings
- Отсутствующий / distorted sealing gasket → Loss of IP65 rating; dust and moisture ingress leads to contact oxidation and poor conductivity
- Excessive torque on mounting nut → Internal mechanism compressed, pushbutton fails to rebound
- Diagonally forcing contact block → Plastic latches fracture; contact block may fall off during equipment operation
- Over-stripped cable and loose copper strands → Risk of short circuit between adjacent terminals
- Panel cutout larger than Φ22.2 mm → Pushbutton wobbles and sealing fails
- Do not mount contact block first then pass pushbutton through panel! Correct sequence: Secure pushbutton head to panel first, then attach contact block
Disassembly Procedure (For contact maintenance & замена)
Cut off power → Pry two latches of contact block with flat screwdriver → Pull contact block backward;
To remove complete pushbutton: Unscrew rear locking nut, extract pushbutton head from panel front.
Operating Principle of Schneider XB2-BA31C (XB2-BA31)
Component composition: ZB2BA3C (green spring return pushbutton head) + ZB2BZ101C (1NO contact block)
It is a mechanical momentary pushbutton without indicator light.
- Mechanical Operating Principle
- Initial state (Unpressed)
Built-in compression spring pushes operating head outward and maintains extended position. Internal moving contact is separated from stationary contact.
- Actuation state (Push down button)
External force depresses green pushbutton head → Internal pushrod travels backward → Drives movable contact bridge inside contact block to displace
Contact bridge connects two stationary contacts simultaneously, терминалы 3 и 4 (НЕТ) закрыто.
- Release state (Automatic return)
When external pressure disappears, built-in spring rebounds and resets pushrod; contact bridge retracts, contacts separate again, circuit between 3 и 4 opens.
Характеристика: Momentary type (jog operation), non-latching; conductive only while being pressed.
- Electrical Principle (XB2-BA31: 1NO Normally Open)
Terminal marking on contact block: 3, 4 = Нормально открытый (НЕТ)
Static status: Circuit open between 3 и 4 (infinite resistance)
Push button: Circuit closed between 3 и 4
Upon release: Circuit restores open state instantly
Contacts are passive mechanical dry contacts:
No built-in power supply; only switches on/off external control circuits. Compatible with low-voltage AC/DC control loops (contactor coils, PLC DI inputs, relay circuits).
- Brief Internal Structure Breakdown
- Pushbutton housing + return spring
- Transmission pushrod (transmit pressing force)
- Contact block: Fixed stationary contacts + movable conductive contact bridge
- Screw wiring terminals
Force transmission sequence:
Manual pressing → Pushbutton head → Pushrod compresses spring → Contact bridge displacement → Contacts closed
Release button → Spring extends and resets → Contact bridge retreats → Contacts open
- Ключевые характеристики
- No built-in indicator lamp, no lighting power supply required; distinguish from illuminated model XB2BW33C.
- Pure physical mechanical contact switching without electronic components, strong anti-interference performance.
- IP65 protection relies on front sealing gasket to prevent water vapour and dust entering contact cavity.
- Typical Application Logic (Motor Start Circuit Example)
Control live L → Terminal 3
Терминал 4 → Contactor KM coil → Neutral N
When XB2-BA31C is pressed → KM coil energizes, contactor pulls in;
Pushbutton circuit opens upon release, continuous operation maintained by self-locking via auxiliary NO contact of contactor.
Common Misunderstandings
❌ Not a latching pushbutton: Circuit opens after release, cannot sustain conduction status
❌ Not suitable as limit switch under continuous compression; accelerates spring fatigue
❌ Contacts only serve control circuits, cannot directly drive high-power loads
Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи