Schneider XCKM102 Limit Switch - Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер

Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

 Schneider XCKM102 Limit Switch - Контактор,автоматический выключатель,датчик,Кодер,ПЛК,Конвертер

электрический/

Schneider XCKM102 Limit Switch

Complete order-part numbers: XCKM102C (Pg11 cable entry)、XCKM102H29 (M20×1.5 cable entry, commonly used in China) Ряд: Telemecanique XC-Standard metal-housing limit switch, actuator ZCK-D02 steel-roller plunger, spring return Model Code Explanation XCKM: M = Zamak zinc-alloy metal housing, modular limit-switch body 102: Contact block: 1NO+1NC snap-action contacts with forced-opening safety NC contact; supplied with ZCK-D02 roller-plunger actuator ...

  • Подробная информация о продукте

Complete order-part numbers: XCKM102C (Pg11 cable entry)、XCKM102H29 (M20×1.5 cable entry, commonly used in China)

Ряд: Telemecanique XC-Standard metal-housing концевой выключатель, actuator ZCK-D02 steel-roller plunger, весеннее возвращение

Пояснение кода модели

XCKM: M = Zamak zinc-alloy metal housing, modular limit-switch body

102: Contact block: 1NO+1NC snap-action contacts with forced-opening safety NC contact; supplied with ZCK-D02 roller-plunger actuator

Suffix C: Pg11 threaded cable entry; Suffix H29: M20×1.5 metric threaded cable entry (mainstream for domestic projects)

Основные технические характеристики

ЭлементПараметр
Конфигурация контактов1 Нормально открытый (NO‑13‑14) +1 Normally‑Closed (NC‑21‑22), snap‑action with forced opening
ПриводTop steel‑roller plunger, весеннее возвращение, bidirectional side actuation
Приводная силаMinimum operating force 12 N; Minimum forced‑opening force 36 N
Электрические параметрыAC‑15 240V /3A; DC‑13 250V/0.27A; Макс. 500 В
ТерминалыВинтовые клеммы, conductor cross‑section 0.34‑1.5 mm²
Класс защитыIP66, IK05
Механическая жизнь20 million operations
Рабочая температура‑25℃~+70℃
Габаритные размеры64×64×30 mm, вес приблизительно. 0.255 кг
Cable Entries3 threaded ports; XCKM102C=Pg11; XCKM102H29=M20×1.5

Определение терминала

13-14: NO Normally-Open

21-22: NC Normally-Closed

⚠️ The NC contact features forced-opening function, designed for safety circuits; do not treat it as an ordinary micro-switch contact.

Типичные применения

Machine-tool hard overtravel limit, конвейерное оборудование, lifting machinery, position detection for automation equipment. Suitable for dusty and splashing-water environments; metal housing provides impact resistance. Модульная конструкция: ZCK-D02 actuator can be replaced separately without changing the whole switch.

Замена & Выбор

  1. Original OEM replacement: XCKM102H29 (M20) / XCKM102C (Pg11)
  2. Альтернативы, совместимые с отечественными производителями: Metal-housing roller-plunger limit switches; verify: 1NO+1NC snap-action, IP66, mounting hole pitch 64 mm
  3. Same-series actuator exchange: Retain switch body, fit various ZCK-XX lever-type actuators.

Распространенные неисправности & Поиск неисправностей

  1. Нет сигнала: Check roller-plunger jamming / spring fatigue; inspect contact burning; verify screw-terminal tightening torque.
  2. Нестабильный сигнал: Reserve sufficient mechanical over-travel; avoid over-compressing plunger; actuating speed ≤0.5 m/s.
  3. Water ingress damage: Match cable gland to entry thread; do not force Pg11 gland onto M20 port.

Примечание: XCKM102 consists of body plus actuator. Confirm cable-entry thread when ordering; XCKM102H29 is preferred for most Chinese field installations.

Сценарии применения Шнайдер XCKM102 Steel-Roller-Plunger Limit Switch

Ключевые особенности: Top steel-roller plunger, bidirectional side actuation, automatic spring return, 1NO+1NC snap-action contacts, forced-opening safety NC contact, IP66 metal housing. Designed for lateral cam-dog actuation, for position confirmation, hard overtravel limiting and safety interlocking.

  1. Machine-Tool Equipment
  2. Станки с ЧПУ, фрезерные станки, токарные станки, шлифовальные машины: Positive/negative hard overtravel protection for slides / work-tables to prevent collision; tool-change position feedback, tailstock position check, pallet clamping confirmation.
  3. Injection-molding machines, die-casting machines: Mold open-close position detection, mechanical safety-gate interlock; ejector-stroke limit.
  4. Press equipment: Slide travel limit, guard-door interlock; NC contact wired into safety circuit.

✅ Selection hint: Plunger requires lateral cam actuation. Cam-dog surface shall be smooth to prevent heavy impact damage to roller.

  1. Material-Handling & Конвейерное оборудование
  2. Belt, roller, цепные конвейеры: Pallet/bin stop-position signal, end-of-travel limit, stop-dog position feedback; sorting-mechanism position signal.
  3. Подъемные платформы, подъемники, stacker cranes: Upper/lower travel limits, fork extend/retract confirmation; over-travel prevention; NC contact for safety cut-off circuit.
  4. Автоматизированные склады: Rail hard limit for shuttle cars, position confirmation.
  5. Упаковка & Printing Production Lines
  6. Упаковочные машины, герметики для корпусов, этикетировщики: Цилиндр / slide position detection, mechanism status feedback; roll-holder limit.
  7. Печатное оборудование: Paper-pile lifting limit, pusher-mechanism position signal.
  8. Лифтинг & Light Machinery
  9. Small overhead cranes, electric chain hoists: Trolley travel limit, lifting-tool position sensing (not for main hoist ultimate height limit — heavy-duty lever-head type is recommended for main hoist).
  10. Robots, gantry axes: Mechanical hard limit (physical backup beyond PLC soft-limit).
  11. Industrial Doors, Ворота & Access Interlocks
  12. High-speed industrial doors, lifting gates: Full-open / full-closed position feedback; safety interlock.
  13. Machine-guard access doors, maintenance hatches: Door-closed confirmation interlock; stop equipment when door opens.
  14. Other Industrial Machinery

Текстильное оборудование: Slider limit for looms & carding machines

Water-treatment & environmental equipment: Gate / baffle position detection

Сборочные линии: Fixture-clamping position confirmation

Operating-Condition Compatibility

✅ Suitable for XCKM102

Lateral cam-dog pushes roller-plunger, linear reciprocating motion

Дасти / splashing-water ambient conditions requiring IP66

Safety circuits requiring forced-opening NC contact

Medium actuating force (≥12 N), immune to minor vibration false-triggering

❌ Not Suitable

  1. Direct vertical impact onto plunger (risk of internal-mechanism damage)
  2. Large-stroke pivoting actuation (use lever-head models e.g. XCK-M115)
  3. Repeated high-speed impact; maximum actuating speed ≤0.5 m/s.

Typical Wiring Practices

  1. Position-reached signal: Использовать 13-14 (НЕТ). Contact closes when cam compresses plunger; status read by PLC.
  2. Hard safety-limit: Проволока 21-22 (Северная Каролина, forced-opening) in series within motor-control circuit. On over-travel impact, hardware directly cuts power, independent of PLC logic.

Complete Technical Specifications for Schneider XCKM102 Limit Switch

Ряд: XC-Standard (Telemecanique); Привод: ZCK-D02 steel-roller plunger, весеннее возвращение, bidirectional side actuation

Order-part variants:

XCKM102C: Pg11 cable entry

XCKM102H29: M20×1.5 metric cable entry (widely used in China)

  1. Механические характеристики
ЭлементПараметр
ПриводSteel‑roller plunger, automatic spring return, bidirectional side actuation
Minimum Operating Force12 Н
Minimum Forced‑Opening Force36 Н (for safety NC contact)
Макс. Permitted Operating Speed0.5 m/s, high‑speed impact not permitted
Мин. Operating Speed0.01 m/min
Механическая жизнь20 million operations
Материал корпусаZamak zinc‑alloy
Габаритные размеры64 × 64 × 30 mm
Вес нетто0.255 кг
Cable Entries3 threaded ports; C‑variant Pg11; H29‑variant M20×1.5
Класс защитыIP66; Impact resistance IK05
Устойчивость к вибрации10‑500 Hz, 25 gn
Ударная устойчивость50 gn, 11 РС
  1. Электрические характеристики
ЭлементПараметр
Конфигурация контактов1НЕТ(13-14)+1Северная Каролина(21-22), snap‑action with forced‑opening NC contact
Условный тепловой ток Ith10 A AC
AC‑15 Inductive Load240 В, 3 А (A300)
DC‑13 Inductive Load250 В, 0.27 А (Q300)
Номинальное напряжение изоляции Ui500 В (Степень загрязнения 3)
Номинальное импульсное выдерживаемое напряжение Uimp6 кВ
Электрическая жизнь (DC‑13)5 million operations
Short‑Circuit Protection10 A gG fuse
ТерминалыКлеммы с винтовыми зажимами, дирижер: 0.34‑1.5 mm², accept two wires per terminal
  1. Условия окружающей среды

Рабочая температура: -25℃ ~ +70 ℃

Температура хранения: -40℃ ~ +70 ℃

Сертификаты: CCC, UL508, CSA; complies with IEC 60947-5-1, IEC 60204-1

  1. Определение терминала

13-14: NO Normally-Open (position-reached signal)

21-22: NC Normally-Closed (forced-opening, for hard-safety-limit circuits)

  1. Ключевые замечания по применению
  2. Designed for lateral cam-dog compression of roller-plunger. Vertical direct impact is not recommended; 30°-angled cam profile is preferred.
  3. Modular construction: ZCK-D02 actuator can be replaced separately without replacing complete switch unit.
  4. Confirm cable-entry thread at ordering: Prefer XCKM102H29 (М20×1,5) for new-build Chinese projects; XCKM102C for legacy Pg11 installations.

Operating Principle of Schneider XCKM102 Limit Switch

XCKM102 is a modular metal-housing mechanical limit switch, fitted with ZCK-D02 roller-plunger actuator. Основной принцип: Mechanical force → plunger displacement → internal snap-action contact toggle → automatic spring return; NC contact implements mechanical forced-opening safety feature, compliant with IEC 60947-5-1.

  1. Mechanical Operating Sequence
  2. Free state (non-actuated)

Cam-dog does not contact roller-plunger; return spring holds plunger outward at home position.

Статус: 21-22 NC closed; 13-14 NO open.

  1. Actuated state (cam-dog compresses roller)

Moving-machine cam-dog laterally pushes steel roller and compresses plunger inward.

Once plunger travels past operating point, internal snap-action rocker mechanism triggers instantaneous contact state change; transition is abrupt, not gradual.

Snap-action benefit: Reliable make-break independent of cam-dog speed; eliminates contact chatter / bounce.

Actuated status: 21-22 NC open; 13-14 NO closed.

  1. Reset process

Cam-dog moves away, external force removed; return spring pushes plunger back to home position, contacts restore original state.

⚠️ Внимание: Designed for lateral compression. Direct vertical pounding on plunger may destroy internal components.

  1. Forced-Opening Principle for Safety NC Contact 21-22 [Критический]

The 21-22 NC contact is not a standard micro-switch contact; it implements mechanical forced-opening construction:

When plunger is fully depressed, rigid mechanical linkage physically pries the NC contacts apart, not relying only on contact-spring force.

Even in case of contact welding / прилипание, mechanical linkage can forcibly separate contacts to break the circuit.

Поэтому 21-22 NC is dedicated to hard-safety-limit and safety-interlock circuits, achieving hardware-level power cut-off independent of PLC software logic.

Never use NO contacts for safety circuits; NO contacts have no forced-opening capability.

  1. Electrical Logic Table
Switch Status13-14 (NO Normally‑Open)21-22 (NC Forced‑Opening Normally‑Closed)
Non‑actuated (home)ОткрытьClosed
Cam‑dog actuatedClosedОткрыть
Cam‑dog retracted, перезагрузитьОткрытьClosed

Two Typical Wiring Modes

  1. Position-feedback signal (PLC digital input): Использовать 13-14 НЕТ; closure indicates target position reached.
  2. Hardware hard-overtravel protection: Series-connect 21-22 NC into contactor-control circuit. Overtravel impact opens switch and directly de-energizes control circuit to avoid machine damage.
  3. Modular Construction Breakdown

XCKM102 consists of three assemblies:

  1. Привод: ZCK-D02 (roller-plunger, возвратная весна) receives external mechanical input.
  2. Contact block: Snap-action rocker-contact assembly performs circuit switching.
  3. Металлический корпус: Provides mechanical mounting, environmental protection and wiring terminals.

Damaged actuator can be replaced separately with ZCK-D02; full-switch replacement is unnecessary.

  1. Fault-Mechanism Analysis
  2. Signal chatter / мерцающий: Cam-dog travel insufficient; plunger stays near transition threshold without full over-travel.
  3. Contacts fail to reset: Plunger jamming; return-spring fatigue or fracture.
  4. Safety-circuit loss: Mis-application of NO contact for safety function; or contact welding (only NC provides forced-opening anti-weld protection).

Предыдущий:

Оставить ответ

Оставить сообщение