Серводвигатель Siemens 1FL6042-2AF21-1AB1

✅ Model Interpretation 1FL6042-2AF21-1AB1 1FL6: SIMOTICS S-1FL6 V90 servo motor series 042: Frame size SH40, 0.75кВт 2: Низкая инерция (ЛИ) А: AC230V single-phase / three-phase F21: Incremental TTL encoder, 2500ппр, cable outlet 1: B5 flange mounting A: With parallel key; Б: With electromagnetic brake Reference: 1AA1 = Same specification without brake 📋 Core Technical Specifications ...

  • Подробная информация о продукте

✅ Model Interpretation

1FL6042-2AF21-1AB1

1FL6: SIMOTICS S-1FL6 V90 серводвигатель ряд

042: Frame size SH40, 0.75кВт

2: Низкая инерция (ЛИ)

А: AC230V single-phase / трехфазный

F21: Incremental TTL encoder, 2500ппр, cable outlet

1: Фланцевое крепление B5

А: With parallel key; Б: С электромагнитным тормозом

Reference: 1AA1 = Same specification without brake

📋 Core Technical Specifications

ЭлементПараметр
Номинальная мощность0.75 кВт (750Вт)
Номинальная скорость3000 об/мин
Номинальный крутящий момент2.39 Н·м
Максимальный крутящий момент7.2 Н·м (3x overload)
Номинальный ток4.7 А
Класс напряжения230 В переменного тока (1переменного тока / 3переменного тока)
КодерIncremental TTL, 2500 ппр
Inertia TypeНизкая инерция (ЛИ)
Shaft ExtensionParallel key shaft, N tolerance class
ТормозBuilt-in electromagnetic brake (power-off holding brake)
Класс защитыIP65 (with shaft oil seal)
Метод охлажденияЕстественное охлаждение
Класс изоляцииКласс Б (130℃)
Frame HeightSH40
Вес неттоПриблизительно. 2.8кг (slightly heavier for brake version)
Совместимый дискSINAMICS V90 (230Версия V: Пульс / PN communication type)
Код ТН ВЭД85015100

🛠️ Application Scenarios

Низкая инерция & высокий динамический отклик, suitable for short-cycle positioning:

СМТ-машины, dispensing machines, small gantries

Упаковочное оборудование, handling manipulators, позиционирование конвейера

Machine tool feed axes, inspection tooling

📌 Matching Components for Selection

  1. Recommended drives: 6SL3210-5FB10-8UA0 (Тип импульса) / 6SL3210-5FB10-8UF0 (PN PROFINET)
  2. Power cable: например. 6FX3002-5CK01-1AD0
  3. Encoder cable: например. 6FX3002-2DB10-1AD0

⚠️ Installation & Примечания по техническому обслуживанию

  1. Температура окружающей среды: 0~40℃ without derating; max relative humidity ≤90%, нет конденсата
  2. Тормоз: Power-off holding brake, released when powered on. The brake cannot be used for dynamic braking during operation, only for holding at standstill.
  3. IP65: Motor body dust-tight and splash-proof; cable connectors must be tightly fastened. Not suitable for long-term immersion.
  4. Монтаж: IM B5 flange, horizontal or vertical installation. Reserve sufficient brake load margin for vertical mounting.
  5. Key inspection points for used motors: Encoder waveform, brake pull-in/release performance, 3-phase winding balance, сопротивление изоляции, bearing noise.

🔁 Alternative Models in the Same Series

1FL6042-2AF21-1AA1: Same parameters, без тормоза

1FL6042-2AF21-1MB1: Single-turn absolute encoder, с тормозом

1FL6042-2AF21-1MA1: Single-turn absolute encoder, без тормоза

Shaft Parameters of Сименс 1FL6042-2AF21-1AB1

Диаметр вала: Φ10 mm, with parallel keyway, shaft tolerance N

Parallel key dimension: 3×3×16 mm

Shaft extension length: 22 мм

Фланец: Б5, frame height 40mm (SH40)

Troubleshooting Checklist for Siemens 1FL6042-2AF21-1AB1 (V90 0.75kW with Brake)

Safety Precaution: Power off and wait 5 minutes for DC bus discharge before plugging/unplugging cables. High voltage hazard. Apply mechanical protection during loaded tests. This motor uses a power-off holding brake. Forcing enable with brake locked will trigger stall alarm directly.

  1. Visual & Механический осмотр (Power OFF, Приоритет)
  2. Motor housing: Check for cracks, water/oil contamination, terminal box corrosion, bent/pushed-out pins or oxidation on connectors.
  3. Кабели: Власть & encoder cables for damaged jacket, sharp bending, незакрепленные клеммы. Separate routing for power and encoder cables; 360° shielding grounding.
  4. Brake Inspection (Critical for this model)

Apply DC24V to brake terminals individually and verify pull-in/release sound. Brake locks when power removed.

After brake release, manually turn shaft: smooth rotation without sticking or friction noise. If still locked → brake mechanical seizure or coil damage.

Measure brake coil resistance: Normal value in tens of ohms. Open circuit = broken coil; near 0Ω = shorted coil.

❗ Brake is not for dynamic braking during operation; only standstill holding.

  1. Bearing check: Manually rotate shaft, listen for rustling, squealing or metal friction noise. Check excessive radial/axial play or jerky rotation.
  2. Coupling & нагрузка: Disconnect load and test motor standalone, to distinguish motor failure from mechanical jamming / misalignment.
  3. Static Electrical Measurement (Power OFF, disconnect all cables from drive side)

Test object: Корпус двигателя, all cables disconnected

  1. DC resistance of 3-phase windings (measure U/V/W pairwise)

Acceptance: Resistance deviation between 3 phases <5%, низкое сопротивление (milliohm range)

Abnormality: Infinite resistance on one phase = broken winding; unbalanced/lower resistance = inter-turn short; near 0Ω = phase-to-phase short.

  1. Сопротивление изоляции (500В мегомметр)

Measure U, В, W to motor PE terminal. ≥1MΩ = acceptable; <0.5MΩ = moisture or insulation breakdown.

  1. Encoder cable continuity: Check A, A-, Б, Б-, З, Z-, power and ground wires one by one for open/short circuit; shield should be continuous.
  2. Brake loop continuity: Measure brake coil resistance; verify brake wires not shorted to earth.

III. Ввод в эксплуатацию без нагрузки (Load disconnected, V90 drive, V-ASSISTANT software)

  1. Drive parameter verification: Motor model must be set to 1FL6042-2AF21-1AB1, encoder type: incremental 2500ppr.
  2. Brake logic: Confirm brake terminal (11/12) outputs DC24V when drive enabled. Brake must be released before PLC/drive enable.
  3. JOG no-load test

Motor runs smoothly without chattering, howling or overheating.

Monitor r0027 motor current: No-load current much lower than rated 4.7A. If no-load current close to rated → brake not fully released, winding fault or abnormal encoder feedback.

  1. Encoder signal monitoring: Use V-ASSISTANT to check actual speed and position. Position should follow continuously during shaft rotation without dropout or jumping. Signal jumping → encoder, cable or EMI interference.
  2. Frequently Occurring V90 Alarm Codes (Motor Related)
Alarm CodeОписание неисправностиMotor-Side Check Points
F7900Motor stall / предел крутящего моментаBrake not released, mechanical jam, UVW phase sequence error, winding damage, torque limit too low
F30001Drive overcurrentMotor phase-to-phase short, утечка на землю, power cable short, winding inter-turn short
F7901 / F31110 / F31112Ошибка энкодераDamaged encoder plug, сломанный кабель / interference, internal encoder failure; Do not share 24V supply with solenoid valves
F7453Actual position value faultAbnormal incremental encoder signal, contaminated/damaged code disc, damaged differential signal wires
A7805I簡t overload warningExcessive continuous load, dragging brake, заклинило подшипник, motor operating above rated current for long period
  1. Targeted Troubleshooting by Symptom

1) JOG command, motor does not rotate, F7900 stall alarm

① Verify 24V brake output, manually confirm free shaft rotation; ② Check UVW phase sequence; ③ Disconnect load for test; ④ Measure 3-phase winding resistance balance; ⑤ Confirm correct motor model parameter.

2) Motor chattering, position drift, occasional position loss without fixed alarm

① EMC grounding, separate power and encoder wiring; ② Inspect encoder connector pins; ③ Isolated 24V control power supply, keep away from solenoid valves; ④ 360° shield grounding of cables; ⑤ Contaminated or damaged internal encoder code disc.

3) Overheating and overload alarm after short operation

① Bearing drag / partially released brake (brake dragging); ② Overloaded machinery; ③ Ambient temperature>40℃; ④ Degraded winding insulation, minor inter-turn short.

4) Drive reports F30001 overcurrent immediately after power-up

① Power cable U/V/W shorted to earth or phase-to-phase; ② Motor winding phase-to-phase or earth breakdown; Do NOT repeatedly power on, to avoid further damage.

  1. Acceptance Test for Second-hand / Used Motors
  2. Визуальный осмотр: Check flange and shaft for impact damage, deformed key, oil seal leakage.
  3. Complete static resistance & испытание изоляции.
  4. Independent 24V brake test for pull-in/release, measure brake coil resistance.
  5. 30min no-load JOG test, monitor current, temperature and vibration.
  6. V-ASSISTANT encoder signal capture, continuous rotation test for stable position reading without jump.
  7. Shaft runout measurement to assess bearing wear.
  8. Cross-check nameplate against ordered part number.

VII. Troubleshooting Decision Logic (Quick Location)

  1. Disconnect load → JOG works fine → Mechanical load fault
  2. Still alarm after load removal → Disconnect motor power & encoder cables, test drive alone → If drive OK, fault is motor or cable
  3. Fault persists after cable replacement → Motor body damage (обмотка / кодер / тормоз / bearing)

⚠️ Prohibited Operations

Do not apply continuous power to brake coil for long time; overheating will burn out the brake coil.

Do not repeatedly JOG with brake locked; risk of motor and drive power module damage.

Disconnect encoder cables fully before megger insulation test. High voltage will destroy encoder instantly.

Overload Capacity of 1FL6042-2AF21-1AB1 (V90 750W Low Inertia)

Rated Torque Mn: 2.39 Н·м

Peak Torque Mmax: 7.20 Н·м

Short-time Overload Ratio: Приблизительно. 300% (3х)

Номинальный ток: 4.7 А

Пиковый ток: 14.2 А

✅ Key Notes

  1. 300% is short-time peak capacity, not for continuous operation. Siemens V90 1FL6 uses drive I²t thermal model to limit overload duration:

300% overload is typically permitted for tens to hundreds of milliseconds, used for acceleration or impact loads. Sustained heavy overload triggers A7805 (I²t overheat warning).

Continuous operation must be ≤100% rated torque.

  1. This overload rating applies to the combination of motor body and matched V90 drive. If drive is undersized, the achievable overload will be limited by the drive and cannot reach 3 раз.
  2. Available peak torque varies with speed: Full 7.2Nm peak torque is available up to rated speed 3000rpm. Peak torque drops in field-weakening region above rated speed.

📌 Selection & Советы по вводу в эксплуатацию

Short acceleration / impact loads can utilize the 3x short-time overload; continuous load must be calculated based on rated torque 2.39Nm.

For vertical axes with brake, reserve safety margin in torque calculation. Do not use peak torque as continuous working torque.

The torque limit parameter in drive is defaulted within motor peak torque. It can be reduced according to mechanical safety requirements.

Предыдущий: