Siemens 3RQ2000-1BW00 Coupling Relay

Industrial coupling relay of Siemens SIRIUS series, оснащен 2 переключающие контакты, wide voltage range 24-240V AC/DC and screw terminals. It serves as a replacement for 3TX7002-1CB00 and 3RS1800-1BW00, and is designed for PLC signal isolation and control circuit coupling. Model Code Interpretation Model Segment Meaning 3RQ Product family code for Siemens SIRIUS coupling / ...

  • Подробная информация о продукте

Industrial coupling relay of Siemens SIRIUS series, оснащен 2 переключающие контакты, wide voltage range 24-240V AC/DC and screw terminals. It serves as a replacement for 3TX7002-1CB00 and 3RS1800-1BW00, and is designed for ПЛК signal isolation and control circuit coupling.

  1. Интерпретация кода модели
Модельный сегментЗначение
3RQProduct family code for Siemens SIRIUS coupling / interface relays
2Generation code, distinguishing from 3RQ0, 3RQ3 and other series
0Basic model with wide voltage range of 24-240V AC/DC
-1Terminal type code: 1 = Screw terminal, 2 = Spring terminal
БContact configuration code: B = 2 переключающие контакты (2СО); A = 1 переключающий контакт (1СО); C = 3 переключающие контакты (3СО)
ВтContact material & characteristic code: W = Standard silver tin oxide (AgSnO) контакт; CW01 = Hard gold plated contact
0Supplementary code for version & specification, no special definition

Полное имя: Enclosed industrial coupling relay, 2 переключающие контакты, 24-240V AC/DC wide voltage, screw terminal connection.

  1. Основные технические параметры
Категория параметраСпецификацияПримечания
Основная информация
Бренд / РядSiemens SIRIUS 3RQ2Industrial-grade signal coupling solution
Номер заказа.3RQ2000-1BW00Standard part number
Тип монтажаDIN rail mount, ширина: 22.5ммCompliant with EN 60715
Защита от проникновенияIP20Finger-proof and dust-proof
Электрические параметры
Control Voltage Range24-240В переменного/постоянного токаWide voltage design for high versatility
Rated Control Power4.5ВтНизкое энергопотребление
Конфигурация контактов2 переключающие контакты (2СО)Each contact consists of 1 НЕТ + 1 Северная Каролина
Rated Contact Current5A @ 250V ACFor resistive load
Макс. Switching Voltage300В переменного/постоянного токаСоответствует МЭК 60947-1
Напряжение изоляции300В (Overvoltage Category III, Степень загрязнения 3)Excellent insulation performance
Импульсное выдерживаемое напряжение4кВСильная устойчивость к перенапряжению
Mechanical Parameters
Размеры (W × H × D)22.5×90×65mmКомпактная структура
МассаПриблизительно. 100гПростая установка
Механическая жизнь1,000,000 операцииВысокая долговечность
Электрическая жизнь100,000 операции (at rated load)Stable and reliable performance
Параметры окружающей среды
Рабочая температура-40°С ~ +60°САдаптация к суровым промышленным условиям
Температура хранения-40°С ~ +85°СWide temperature range for storage
Humidity Range5%~95% (неконденсирующийся)Suitable for humid conditions
Степень загрязнения3Applicable to dusty industrial sites
  1. Кросс-брендовый & Obsolete Model Replacement List
Оригинальная модельЗапасная модельReplacement Description
Siemens 3TX7002-1CB003RQ2000-1BW00Официальная рекомендуемая замена; 22.5mm width unchanged, fully function compatible
Siemens 3RS1800-1BW003RQ2000-1BW00Official replacement; discontinued since Oct 1, 2022
Siemens 3RQ2000-1AW003RQ2000-1BW00In-series upgrade from 1CO to 2 переключающие контакты
Schneider RXM4AB2BD3RQ2000-1BW00Функционально эквивалент; 2СО, 24-240В переменного/постоянного тока, DIN rail mount
ABB CR-M230AC23RQ2000-1BW00Функционально эквивалент; 2СО, wide voltage, industrial application

Selection Tips: Verify full consistency of contact quantity, тип терминала, mounting dimensions and electrical parameters before replacement.

  1. Full Model List of 3RQ2000 Series
МодельКонфигурация контактовТип терминалаКонтактный материалДиапазон напряженияПримечания
3RQ2000-1AW001СОВинтСтандартный24-240В переменного/постоянного токаБазовая модель
3RQ2000-1BW002СОВинтСтандартный24-240В переменного/постоянного токаSubject model
3RQ2000-1CW003СОВинтСтандартный24-240В переменного/постоянного токаMulti-contact model
3RQ2000-1CW013СОВинтHard gold plated24-240В переменного/постоянного токаВысокая надежность, for light load
3RQ2000-2AW001СОSpringСтандартный24-240В переменного/постоянного токаFast wiring model
3RQ2000-2BW002СОSpringСтандартный24-240В переменного/постоянного токаSpring terminal, 2 переключающие контакты
3RQ2000-2CW003СОSpringСтандартный24-240В переменного/постоянного токаSpring terminal, 3 переключающие контакты
3RQ2000-2CW013СОSpringHard gold plated24-240В переменного/постоянного токаSpring terminal, высокая надежность
  1. Распространенные неисправности & Поиск неисправностей
Явление неисправностиВозможные причиныРешения
Relay fails to operate1. Control voltage out of range1. Measure voltage and ensure it is within 24-240V
2. Loose terminals2. Check and tighten screw terminals
3. Сгоревшая катушка3. Replace the relay
Плохой контакт контактов1. Окисление / contamination of contacts1. Clean contacts or replace the relay
2. Contact welding caused by overload2. Reduce load or select higher-capacity model
3. Excessive vibration during operation3. Fasten installation and add vibration dampers
Indicator light off while relay operates normally1. Damaged LED indicator1. Replace LED module
2. Fault of indicator circuit2. Inspect wiring of indicator circuit
Random operation of relay1. Interference on control circuit1. Use shielded cables and keep away from interference sources such as inverters
2. Severe voltage fluctuation2. Install voltage stabilizer
3. Ambient temperature out of limit3. Improve heat dissipation or select high-temperature resistant model
Overheated terminals1. Ослабленная проводка1. Retighten terminals
2. Undersized wire cross-section2. Replace with wires of proper cross-section
3. Excessive load current3. Reduce load or replace the relay
  1. Область применения & Отраслевые случаи

6.1 Применимые сценарии

PLC Signal Isolation: Couple signals between PLC outputs and field actuators to protect PLC modules.

Расширение цепи управления: Increase available control signals to drive multiple loads via one signal.

Voltage Conversion: Connect control circuits with different voltage levels, например. 24V DC PLC output for 220V AC contactors.

Interference Suppression: Isolate signals in high-interference environments such as inverters and welding equipment to avoid false triggering.

Системы промышленной автоматизации: Контроль производственной линии, упаковочное оборудование, станки, conveyor systems, и т. д..

6.2 Нерекомендуемые сценарии

High-frequency switching: Not suitable for frequent switching over 10 cycles per second.

Inductive load without protection: Surge suppressors are mandatory when driving inductive loads such as motors and solenoid valves.

Corrosive environments: No special anti-corrosion treatment; not for strong acid, alkali or high salt mist conditions.

Explosive hazardous areas: Невзрывозащищенное исполнение; prohibited for flammable and explosive locations.

6.3 Типичные случаи применения

Случай 1: Automotive Component Production Line

Приложение: PLC controls clamps and welding torches of robotic welding stations.

Конфигурация: 3RQ2000-1BW00 isolates PLC output signals from 220V AC solenoid coils.

Result: Resists welding current interference; failure rate reduced by 90%, maintenance cost cut by 50%.

Случай 2: Еда & Beverage Filling Line

Приложение: Connect HMI touch panel and filling valve control circuits.

Конфигурация: Two units of 3RQ2000-1BW00 control 4 filling valves (2 НЕТ + 2 Северная Каролина) via one HMI signal.

Result: Simplified wiring, improved system reliability and fewer spare part types.

Случай 3: Intelligent Warehousing System

Приложение: Isolate position sensor signals of stacker cranes and PLC inputs.

Конфигурация: 3RQ2000-1BW00 converts 24V DC sensor signals to PLC-compatible signals.

Result: Eliminates interference from long-distance signal transmission; positioning accuracy improved to ±1mm.

  1. Рекомендации по выбору & Quick Reference Rules
  2. Contact quantity by letter: A = 1CO, B = 2CO, C = 3CO
  3. Terminal type by digit: 1 = Screw terminal, 2 = Spring terminal
  4. Contact material by suffix: W = Standard contact, CW01 = Gold-plated contact
  5. Universal voltage: Full series supports 24-240V AC/DC
  6. Priority for replacement: Directly replace 3TX7 / 3RS18 series with corresponding 3RQ2000 models

Ordering Notice: Standard package: 1 единица в коробке; Минимальный объем заказа: 1 единица. It is recommended to prepare 2~3 units as spare parts for general industrial automation control.

Common Faults and Troubleshooting of Siemens 3RQ2000-1BW00 Coupling Relay

  1. Relay Fails to Operate Completely
  2. No power supply to coil

Measure input voltage to confirm it is within 24~240V AC/DC. Check circuit breakers, fuses and continuity of upstream control circuits, and tighten loose terminals.

  1. Loose / poor terminal connection

Retighten screw terminals. Check wire crimping, broken wires and wires trapped under terminal screws.

  1. Сгоревшая катушка

Long-term overvoltage or frequent voltage surges will burn the coil. Replace the relay if burnt marks or abnormal odour are observed.

  1. Механические помехи

Accumulated dust and continuous vibration cause internal armature sticking. Tap the housing gently for test; replace the relay if the issue persists.

  1. Coil Pulls In but Contacts Open / Плохой контакт
  2. Oxidation and dust accumulation on contacts

Commonly seen in humid and dusty environments, especially for low-power signal circuits. Clean contacts after power cut and test with repeated switching operations.

  1. Контактная сварка

Excessive load current or frequent inrush load leads to stuck contacts. Disconnect the load for verification. Replace the relay as welded contacts cannot be repaired.

  1. Fault on load side circuit

Troubleshoot downstream contactors, solenoid valves and broken wires. Confirm relay fault only after excluding external failures.

  1. Random Operation / Unexpected On & Выключенный
  2. Electromagnetic interference

Easily affected when installed close to inverters, моторы, high-power contactors or long control cables. Route control cables away from power cables and apply shielded wires and surge absorbers.

  1. Voltage fluctuation & electrical noise

Sudden voltage drop and voltage spikes cause false operation. Install voltage stabilizers and filters on the upstream side.

  1. Abnormal ambient temperature

Operation above +60°C or condensation under low temperature leads to internal circuit malfunction. Улучшите вентиляцию, dehumidification and heat dissipation.

  1. Abnormal Indicator Light
  2. Light off, relay works normally

Only the LED bulb is damaged. The relay can remain in service or be replaced.

  1. Light always on / flickering, relay does not operate

Malfunction of internal voltage divider and indicator circuit, usually accompanied by coil failure. Replace the relay directly.

  1. Overheated Wiring Terminals
  2. Ослабленная проводка: Retighten terminals to specified torque.
  3. Undersized wire gauge: Replace with cables with cross-section matching the load current.
  4. Continuous overload: Actual load exceeds rated 5A contact current. Apply load sharing or use higher-capacity relay.
  5. Frequent Failures under Inductive Load (Solenoid / Контактор)

Symptoms: Shortened contact service life, frequent contact welding and unexpected tripping

Поиск неисправностей: The absence of surge suppressors causes reverse high voltage from inductive loads to damage contacts during power-off. Connect freewheeling diodes (для постоянного тока) or RC snubbers (для переменного тока) in parallel across inductive loads.

  1. On-site Quick Troubleshooting Procedure
  2. Cut off power → Inspect appearance, wiring and terminal tightness
  3. Switch on power → Measure input control voltage
  4. Observe indicator light and listen to pull-in sound to judge coil status
  5. Cut off power → Test NO/NC contacts with multimeter continuity mode
  6. Distinguish faults among upstream control circuit, relay itself and downstream load circuit

Предыдущий: