Schneider Electric C125N420FM Molded Case Circuit Breaker

Product Overview & Model Breakdown

C125N420FM is a 4‑pole molded case circuit breaker from Schneider Electric’s ComPacT NS1250N series, equipped with a MicroLogic 2.0 control unit.

It is used for overload and short‑circuit protection in low‑voltage power distribution systems, widely applied in industrial plants, commercial buildings, and infrastructure projects.

Model SegmentDescription
C125NComPacT NS1250N series, frame size 1250A, breaking capacity 50kA@415VAC
44‑pole configuration (4P)
20MicroLogic 2.0 control unit (basic protection functions)
FMFixed mount, manual operation, front connection
  1. Core Technical Specifications
ItemValueNotes
ModelSchneider Electric C125N420FMFull description: ComPacT NS1250N 4P 1250A 50kA MIC2.0
Frame current1250AMaximum rated operational current
Poles4 poles (4P)3 phases + neutral protection
Trip unitMicroLogic 2.0Long‑time (L), short‑time (S), instantaneous (I) protection
Rated current (Ir)1250AAdjustable via trip unit
Ultimate breaking capacity (Icu)50kA@415VACComplies with IEC 60947‑2
MountingFixed, front connectionSuitable for standard switchgear
OperationManualWith mechanical indication and lockability
Rated insulation voltage (Ui)1000VACIEC 60947‑2
Rated operational voltage (Ue)400/415VAC (50Hz)Standard 3‑phase voltage
Short‑time withstand current (Icw/1s)50kAEnsures system stability during faults
Protection degreeIP30Protection against solid foreign objects
Wiring capacityMax. 300mm² copperFor high‑current loads
  1. Features & Advantages
  2. Comprehensive protection

MicroLogic 2.0 provides 3‑stage protection (L‑S‑I) with adjustable settings.

Supports fault diagnostics and alarm output for easy maintenance.

  1. Efficient design

Green “T” design reduces panel wiring time by 40%.

Ergonomic operating handle for improved safety and comfort.

Modular structure supports accessories: auxiliary contacts, alarm contacts, undervoltage release, etc.

  1. Reliable performance

50kA high breaking capacity for fast fault interruption.

Mechanical life: up to 10,000 operations; electrical life: up to 5,000 operations.

Ambient temperature: −5°C to +40°C (full rating), −25°C to +70°C (derated).

  1. Installation & Applications

4.1 Installation Requirements

Suitable for standard distribution boards with industry‑standard mounting depth.

Front connection for easy wiring and maintenance.

Sufficient heat dissipation space required for stable long‑term operation.

4.2 Typical Applications

Incoming protection for main power distribution boards in industrial plants

Power distribution systems for large commercial complexes

UPS input/output protection in data centers

Critical load protection in infrastructure (hospitals, airports, metros)

Main protection for Motor Control Centers (MCC)

  1. Related Models & Alternatives

5.1 Derived models in the same series

ModelDifferenceApplication
C125N320FM3 poles (3P)3‑phase loads without neutral protection
C125N450FMMicroLogic 5.0 trip unitEnergy measurement and advanced protection
C125N420PMDraw‑out installationEasy maintenance without power interruption
C125N420RMPlug‑in installationFast replacement for backup equipment

5.2 Cross‑series alternatives

ReplacementSeriesMain differencePrice reference
NSX1250N 4P MIC2.0ComPacT NSXNew generation, breaking capacity 65kAApprox. +10%
Masterpact MTZ12Masterpact MTZAir circuit breaker for higher power systemsApprox. +50%

5.3 Competitive brand equivalents

BrandReplacementRating
Siemens3WL1212‑3CB36‑4GA41250A 4P 50kA basic protection
ABBTmax T6H1250 PR221DS‑LSI 4P1250A 4P 50kA LSI protection
EatonNZM4‑1250N 4P1250A 4P 50kA basic protection
  1. Purchasing & Usage Tips
  2. Authentic procurement: Purchase via authorized Schneider Electric distributors or official channels to ensure quality and service.
  3. Accessories: Optional auxiliary contacts, alarm contacts, shunt trip, undervoltage release, etc.
  4. Parameter setting: MicroLogic 2.0 can be programmed; adjust according to load characteristics.
  5. Maintenance: Routine inspection every 1–2 years, including mechanism, terminals, and protection functions.

> Note: C125N420FM complies with IEC 60947‑2, GB 14048.2 and other international & national standards. It is fully compatible with Schneider Prisma E, Blokset and other panel systems.

  1. Selection & Replacement Guidelines
  2. Compatibility Rules

Industrial relay sockets follow international standard dimensions and are interchangeable across brands if:

Pin count matches relay pole number

Rated current (≥10A) meets load

Mounting (DIN-rail/screw) matches panel design

  1. Terminal Type Selection

Conventional screw: PTF08A / PTF11A / PTF14A-suitable for low-vibration environments

Finger protection: PTFZ series-suitable for areas with frequent access

Push-In Plus: PTF-PU series-ideal for mass wiring, high vibration resistance

  1. Discontinued Models

PTF08A-E / PTF14A-E are discontinued with limited stock.

Use PTFZ series as the preferred replacement.

> Note: PTF series sockets are rated 10A/250VAC, dielectric strength AC 2000V, operating temp −25 °C to +55 °C, suitable for 0.5–2.5 mm² copper wires.