This product is a non-automatic load break isolator from Schneider Electric’s Interpact INS series, with the official order code 31114.

It is designed for power isolation and maintenance safety in low-voltage distribution systems.

It is 3-pole, rated current 630A, rated voltage 690VAC, without short-circuit or overload protection, and is used only for isolation purposes.

  1. Model Breakdown
Model PartMeaningKey Description
CompactProduct platformSchneider compact distribution platform, suitable for limited panel space
INSSeries codeInterpact INS series, non-automatic load break isolator, isolation only, no protection
630Frame / rated currentFrame size 630A, operational current 630A (AC-22A / AC-23A)
3 PoleNumber of poles3P (three-phase three-wire), no neutral pole, not suitable for neutral isolation in TN‑S / TT systems
31114Official order codeUnique code for standard version (black rotary handle, fixed mounting)
  1. Key Technical Specifications (Official Standard)
ItemSpecificationApplicable Standard
Product typeNon-automatic load break isolatorIEC 60947-3, EN 60947-3
Rated voltageAC 690V, Ui 750VSuitable for 380/415/480V industrial systems
Rated current630A (AC-22A / AC-23A)Continuous operation ≤ 630A, recommended duty ≤ 80% (≤ 504A)
Short-time withstand current11.5kA/3s, 20kA/1s, 4kA/30sWithstands short-circuit current only, no breaking capacity
Impulse withstand voltageUimp 8kVLightning and overvoltage protection
OperationManual rotary handle (black)Motor operation available (separate order)
MountingFixed typeFront / rear connection, 35mm DIN rail or panel mount
Ingress protectionIP20 body, IP55 with handleIndoor panels or outdoor enclosures
Mechanical endurance10,000 operationsExceeds standard industrial requirements
  1. Series Model List (630A Frame)
Model (Order Code)PolesTypeApplication
INS630 3P (31114)3PStandard isolatorIncoming, bus-coupler, equipment isolation (3-phase 3-wire)
INS630 4P (31115)4PStandard isolatorIsolation with neutral (3-phase 4-wire)
INS630 3P Changeover (31154)3PManual changeover switchMains / generator manual switching
INS630 4P Changeover (31155)4PManual changeover switch3-phase 4-wire dual power switching

Extended Current Ratings

Current3P Code4P CodeBreaking Characteristics
400A3111231113Same as INS630, current only
500A3111631117
630A3111431115This model
  1. Recommended Equivalent Models from Other Brands
BrandSeriesEquivalent ModelMatching ParametersNotes
LS ElectricMeta-MEC ISIS630N-3P3P, 630A, 690V, isolatorEconomic version
ABBOTOT630E033P, 630A, 690V, isolatorVisible break
Siemens3KD3KD4630-0NE103P, 630A, 690V, isolatorMotor operation compatible
EatonNZMNZM3-XT6303P, 630A, 690V, isolatorEnhanced interlocking
Changshu SwitchCM1GCM1G-630/33003P, 630A, 690V, isolatorDomestic high cost‑performance
  1. Typical Applications (Isolation Only, No Protection)
  2. Industrial Plants
ApplicationReasonRecommendation
Production line main isolation630A suitable for ≤315kW three-phase loadsUsed in series with NSX630N circuit breaker
Large motor circuit isolationMotors above 200kW (fans, pumps, compressors)Complete protection with contactor & relay
Panel bus-coupler isolationDual power supply systemsMechanical interlock recommended
  1. Commercial & Public Buildings

Office / shopping mall incomer isolation with EZD630 breakers

Secondary distribution isolation in hospitals and schools

Infrastructure partial isolation (metro, airport utilities)

  1. Special Applications

Generator outlet isolation ≤500kVA

Capacitor bank isolation ≤300kvar

Construction site temporary power isolation

  1. Selection & Operation Guidelines
  2. Selection Rules
FactorCorrect SelectionRisk of Wrong Selection
FunctionIsolation only; must be used with a circuit breakerNo protection, equipment burnout
Poles3P for IT systems; 4P for TN‑S / TTRisk of electric shock without neutral isolation
CurrentTotal load ≤ 504A (80% duty)Overheating, reduced life
Short-circuitSystem Isc ≤ 11.5kA/3sContact welding, failure to open
  1. Safety Rules
  2. Do NOT break under load — operate only at no-load or light load
  3. Use interlocks with upstream breakers
  4. Indoor dry environment (-25°C ~ +70°C); outdoor needs IP55 enclosure
  5. Accessories: auxiliary contacts, motor operation, padlock attachment available
  6. Key Difference from Circuit Breaker
ItemCompact INS630 3PCompact NSX630N 3P
TypeLoad break isolatorMolded case circuit breaker (MCCB)
FunctionIsolation onlyOverload + short-circuit protection
Breaking capacityNone, withstand onlyIcu = 50kA @ 415V
UsageManual isolation for maintenanceAutomatic protection during operation
ConnectionInstalled after breakerMain protection device

Schneider Compact INS630-3P (order code 31114) is a dedicated isolation device for safe maintenance in LV distribution systems.

It must be used with a circuit breaker.

If you require both protection and isolation, use NSX630N.

For economic alternatives, consider LS IS630N or Changshu CM1G.