A9L40600 Schneider surge protection

Model A9L40600 SchneiderModel Analysis and Technical Parameters A9L40600 is the complete order number of a low-voltage surge protection product (Surge Arrester) under Schneider Electric‘s Acti9 Series. It belongs to the iPRD40 modular surge arrester series and is mainly used for Type 2 surge protection in power distribution systems. Model Segment Analysis Code Segment ...

  • รายละเอียดสินค้า

Model A9L40600 SchneiderModel Analysis and Technical Parameters

A9L40600 is the complete order number of a low-voltage surge protection product (Surge Arrester) under ชไนเดอร์ อิเล็คทริค‘s Acti9 Series. It belongs to the iPRD40 modular surge arrester series and is mainly used for Type 2 surge protection in power distribution systems.

  1. Model Segment Analysis
Code SegmentDescriptionCorresponding Product Attribute
A9Schneider Acti9 Series IdentifierA standardized low-voltage component series for terminal power distribution, including circuit breakers, surge arresters, ฯลฯ.
L40Product Type Sub-codeRepresents the iPRD40 series modular surge arrester. “ล” generally indicates surge protection products, และ “40” corresponds to the 40kA maximum discharge current rating.
600Structural Feature and Configuration CodeCorresponding to 3P+N (สามเฟส + neutral) pole configuration, 350V rated voltage, and equipped with a pluggable trip module
  1. Summary of Core Product Attributes
ItemSpecification Parameter
Brand and SeriesSchneider Acti9 iPRD40 Series
Product Typeพิมพ์ 2 modular surge arrester (with pluggable trip unit)
Pole Configuration3พี+เอ็น (สามเฟส + neutral)
แรงดันไฟฟ้าที่ได้รับการจัดอันดับ (Uc)350วีและ (suitable for domestic 400V three-phase systems)
Maximum Discharge Current (Imax)40ที่ (8/20μs waveform)
ระดับการป้องกันพิมพ์ 2 (secondary surge protection for power distribution systems)
Technical PrincipleCombined technology of MOV (Metal Oxide Varistor) + GDT (Gas Discharge Tube)
Applicable Earthing SystemTN-S, TT systems (not applicable to TN-C, IT systems)
  1. Detailed Technical Parameter Table
Parameter CategorySpecific ValueRemarks
Electrical Parameters
จัดอันดับแรงดันไฟฟ้าที่ใช้งาน350วีและ50/60เฮิรตซ์
Maximum Discharge Current40ที่ (8/20μs)Core indicator of surge protection
Nominal Discharge Current20ที่ (8/20μs)
Voltage Protection Level (Up)≤ 1.5kVMeasured at In=10kA
Response Time≤ 25nsMOV+GDT combined technology ensures fast response
Mechanical and Installation Parameters
Module Width4 โมดูล (72มม)Suitable for 35mm DIN standard rail
ขนาด85มม (H) × 72mm (W) × 69mm (ดี)
TerminalSuitable for 2.5~35mm² copper conductorsRecommended torque: 8~10N·m
ระดับการป้องกันIP20Suitable for installation inside power distribution cabinets
Environmental and Service Life Parameters
Operating Temperature-25°C ~ +60°C
Storage Temperature-40°C ~ +85°C
Mechanical Service Life 10,000 ครั้ง (plug-in operation)
Electrical Service LifeComplies with IEC 61643-11 มาตรฐานThe pluggable module can be replaced when surge protection components age
Certification and Standards
Compliant Standardsไออีซี 61643-11, GB 18802.1Certified with CE and CCC
  1. Core Functions and Working Principle
  2. Surge Suppression Mechanism: Adopts MOV+GDT hybrid technology. MOV is responsible for fast response (≤25ns) to suppress most surges, while GDT provides higher surge withstand capacity and lower leakage current.
  3. Fault Indication Function: The pluggable module is equipped with a visual status indicator (green = normal, red = fault) for quick identification of protection status.
  4. Thermal Trip Protection: Built-in thermal trip device automatically trips when surge energy is excessive or components age, preventing overheating damage to the arrester.
  5. Replaceable Design: Only the pluggable trip module needs to be replaced after a fault, eliminating the need for overall replacement and reducing maintenance costs.
  6. สถานการณ์การใช้งานทั่วไป
Application FieldSpecific Application ScenarioProtection Target
อาคารพาณิชย์Main/distribution power cabinets in office buildings, shopping malls, โรงแรมProtect critical loads such as air conditioners, elevators, and lighting systems
Industrial PlantsProduction line control circuits, PLC systems, front-end of frequency convertersPrevent damage to precision electronic equipment caused by lightning strikes or grid fluctuations
Data CentersUPS input/output terminals, front-end of server cabinet PDUsEnsure continuous and stable operation of IT equipment and avoid data loss
InfrastructureCritical power distribution circuits in hospitals and transportation hubsProtect life-safety related equipment and control systems
Photovoltaic SystemsAC side output terminals of invertersSuppress surges generated by photovoltaic systems and grid feedback surges
  1. Installation and Operation Precautions
  2. Installation Location:

As Type 2 protection, it should be installed in the main or distribution power cabinet, after the main circuit breaker.

Recommended to be installed close to the protected equipment, with the line length not exceeding 10 เมตร.

  1. ข้อกำหนดการเดินสายไฟ:

Phase lines (L1/L2/L3) and neutral line (เอ็น) must be wired correctly according to the markings.

The protective earthing (วิชาพลศึกษา) wire should be as short and thick as possible. It is recommended to use ≥16mm² copper conductors with a length not exceeding 50cm.

All terminals must be tightened to the recommended torque (8~10N·m) to prevent overheating due to poor contact.

  1. Matching Requirements:

A 16A~32A miniature circuit breaker or fuse must be installed upstream as overcurrent protection to prevent short circuits caused by surge arrester faults.

Not applicable to IT and TN-C earthing systems, only suitable for TN-S and TT systems.

  1. Maintenance Points:

Regularly check the status indicator (green = normal, red = fault).

Replace the pluggable trip module in a timely manner after a fault; do not perform plug-in operations with power on.

It is recommended to conduct a surge protection performance test every 2 ปี.

  1. Reference of Related Models in the Same Series
Modelหมายเลขขั้วโลกMaximum Discharge Currentแรงดันไฟฟ้าที่ได้รับการจัดอันดับApplication Scenario
A9L402001พี+เอ็น40ที่350วีพิมพ์ 2 surge protection for single-phase power distribution systems
A9L404002พี+เอ็น40ที่350วีTwo-phase power distribution systems (เช่น, lighting systems)
A9L406003พี+เอ็น40ที่350วีThree-phase power distribution systems (mainstream model)
A9L156003พี+เอ็น15ที่350วีPlaces with low surge risk

 