วีแชท: +86-13184948252 วอทส์แอพพ์: 0086-13811255435 อีเมล: kent@bestcontactor.com

เกี่ยวกับ ติดต่อ |

Chint NM1-125S/3300-63A Molded Case Circuit Breaker - คอนแทคเตอร์,เบรกเกอร์,อินเวอร์เตอร์พลังงานแสงอาทิตย์,มิเตอร์ไฟฟ้า,แบตเตอรี่พลังงานแสงอาทิตย์

เบรกเกอร์/

Chint NM1-125S/3300-63A Molded Case Circuit Breaker

The Chint NM1-125S/3300-63A Molded Case Circuit Breaker (เอ็มซีซีบี) is a high-performance power distribution protection device in the NM1 series of Chint Group (CHNT). It is suitable for power distribution systems with an AC frequency of 50Hz and a rated operating voltage up to 690V, and is mainly used for overload, ลัดวงจร, and under-voltage protection. The following is ...

  • รายละเอียดสินค้า

The Chint NM1-125S/3300-63A Molded Case Circuit Breaker (เอ็มซีซีบี) is a high-performance power distribution protection device in the NM1 series of Chint Group (CHNT). It is suitable for power distribution systems with an AC frequency of 50Hz and a rated operating voltage up to 690V, and is mainly used for overload, ลัดวงจร, and under-voltage protection. The following is a detailed analysis based on Chint’s official data and industry standards:

  1. Core Parameters and Technical Characteristics
  2. พารามิเตอร์พื้นฐาน

จัดอันดับปัจจุบัน (In): 63ก, suitable for the load requirements of the circuit.

Frame Current (Inm): 125ก, indicating the maximum current-carrying capacity of the circuit breaker.

ทำลายความจุ:

Rated Ultimate Short-Circuit Breaking Capacity (ห้องไอซียู): 35ที่ (at 400V), meeting the safety requirements of medium and high-risk power distribution scenarios.

Rated Service Short-Circuit Breaking Capacity (Ics): 18ที่, ensuring the circuit breaker can operate reliably after multiple faults.

หมายเลขขั้วโลก: 3 เสา (the first “3” in 3300), applicable to three-phase four-wire or three-phase three-wire systems.

Tripping Characteristics:

Thermomagnetic Release (the second “3” in 3300), with both overload long-time delay (inverse time) and short-circuit instantaneous protection functions.

Inverse Time Operation Characteristics: The conventional non-tripping current is 1.05In (no tripping within 2 ชั่วโมง), the conventional tripping current is 1.30In (tripping within 2 ชั่วโมง), and the instantaneous operation is set to 10In±20%.

  1. Electrical Performance

Rated Insulation Voltage (Ui): 800วี, supporting the compatibility of high-voltage level systems.

การปฏิบัติตามมาตรฐาน: GB/T 14048.2 (equivalent to IEC 60947-2), and has obtained certifications such as CCC, KEMA, และซีอี, ensuring international versatility and reliability.

  1. การออกแบบโครงสร้าง

วิธีการติดตั้ง: Supports vertical or horizontal installation, flexibly adapting to different cabinet layouts.

Wiring Method: การเดินสายไฟที่แผงด้านหน้า (standard configuration); some upgraded models offer plug-in design (เช่น, NM1-125S/3300 63A G).

Arc Flash Distance: ≤50mm, reducing the risk of damage to surrounding equipment caused by fault arcs.

  1. Application Scenarios and Typical Configurations
  2. ฟิลด์แอปพลิเคชัน

Industrial Power Distribution: Power protection for power equipment such as machine tools and production lines.

อาคารพาณิชย์: Control of distribution boxes and branch circuits in office buildings and shopping malls.

Residential and Small-Scale Infrastructure: Overload protection for indoor main incoming lines or high-power electrical appliances (เช่น, เครื่องปรับอากาศ, electric water heaters).

  1. Accessory Expansion

ฟังก์ชั่นเสริม: Can be equipped with a shunt release (for remote circuit breaking), an under-voltage release (for automatic disconnection when voltage is abnormal), or an alarm contact (for fault status signal output) to meet the needs of intelligent control.

Installation Compatibility: Accessory modules are universal with other models in the NM1 series, facilitating later function upgrades.

III. Usage and Maintenance Recommendations

  1. ข้อมูลจำเพาะการติดตั้ง

ข้อกำหนดด้านสิ่งแวดล้อม: Ambient air temperature ranges from -5℃ to +40℃, altitude ≤2000m, and strong magnetic field interference should be avoided.

ข้อกำหนดการเดินสายไฟ: Tighten terminal bolts to the specified torque (refer to the manual) to ensure reliable contact and prevent overheating.

  1. Operation and Maintenance Key Points

การตรวจสอบเป็นประจำ: Clean the dust on the housing every six months, check the wear of contacts, and replace them if necessary.

,Fault Troubleshooting: หากเกิดการสะดุดล้มบ่อยๆ, it is necessary to check whether the load exceeds the limit, whether the line is short-circuited, or whether the setting value of the release is reasonable.

  1. Replacement and Upgrade

New Model Replacement: Since 2021, Chint has launched upgraded platform-type products (models with suffixG”), such as NM1-125S/3300 63A G. The breaking capacity is increased to 50kA, and the installation dimensions are compatible with the old models, enabling seamless replacement.

Local Procurement: Contact Chint’s authorized distributor via WhatsApp: 0086-13811255435 to obtain spot goods and technical support.

  1. Key Considerations for Selection
  2. Matching of Breaking Capacity: Select the corresponding breaking level (เช่น, Type S: 35ที่, Type H: 50ที่) according to the short-circuit current level to avoid equipment damage due to insufficient selection.
  3. Adaptation of Tripping Curve: For power distribution scenarios, ประเภทซี (5-10 times In instantaneous tripping) is preferred; for motor protection, Type D (10-14 times In) เป็นสิ่งจำเป็น.
  4. Certification Compliance: For domestic projects, CCC certification must be confirmed; for export projects, attention should be paid to the standards of the target market (เช่น, CE, NOM).

ก่อนหน้า:

ต่อไป:

ทิ้งคำตอบไว้