รายละเอียดรหัสรุ่น (E3T-ST23M with 2M Cable)
| เซ็กเมนต์ | คำนิยาม |
| E3T | Series of ultra-miniature thin built-in amplifier เซ็นเซอร์ตาแมว |
| เซนต์ | Through-beam opposed type |
| 2 | Body size specification, 300 mm sensing distance model |
| 3 | Output logic: PNP Light-ON |
| ม | รูยึดแบบเกลียว M3 (models without M adopt M2 mounting) |
| 2ม | Standard 2-meter outgoing cable |
Split components sold as a complete set: Emitter E3T-ST23-L, Receiver E3T-ST23-D
- Core Basic Specifications
- Optical Performance
Sensing method: Through-beam opposed type (paired emitter + receiver)
Rated sensing distance: 300 มม
Light source: 650 nm visible red LED
วัตถุที่ตรวจพบขั้นต่ำ: φ2 mm opaque solid object
Beam angle: Transmitting 2°~20°, Receiving 2°~70°
เวลาตอบสนอง: 1 นางสาว
Indicators: Orange operation indicator, green stability margin indicator
- ไฟฟ้า ข้อมูลจำเพาะ
แรงดันไฟฟ้า: 12~24 V DC ±10%, peak-to-peak ripple ≤10%
Current consumption: Emitter ≤10 mA, Receiver ≤20 mA
ประเภทเอาต์พุต: PNP open collector
โหมดการทำงาน: เปิดไฟ (output turns ON when light is received)
คะแนนโหลด: สูงสุด. 50 มิลลิแอมป์, load voltage ≤26.4 V DC
Residual voltage: ≤2 V for 10~50 mA load; ≤1 V for load below 10 มิลลิแอมป์
ฟังก์ชั่นการป้องกัน: การป้องกันการกลับขั้ว, การป้องกันการลัดวงจรเอาต์พุต, mutual interference suppression
- เครื่องกล & ข้อมูลจำเพาะด้านสิ่งแวดล้อม
การติดตั้ง: Fixed with M3 screws (mounting screws not included, จะต้องซื้อแยกต่างหาก)
Ingress protection class: IP67
วัสดุที่อยู่อาศัย: พลาสติกวิศวกรรม PBT
Cable outlet: 2 m 4-core straight cable
Weight per set: ประมาณ. 20 ก
อุณหภูมิในการทำงาน: -25 ℃~ +55 ℃ (ไม่มีการควบแน่น)
การรับรอง: ซีอี, RoHS, แอล
III. คำจำกัดความของการเดินสายไฟ (4-สายเคเบิลหลัก, receiver side)
- สีน้ำตาล: DC12~24 V positive (+)
- สีฟ้า: 0 V negative (จีเอ็นดี)
- สีดำ: PNP signal output (connect load positive to black wire, load negative to 0 วี)
- สีขาว: ไม่ได้ใช้ (empty pin)
The emitter only has 2 สายไฟ: สีน้ำตาล (+), สีฟ้า (จีเอ็นดี), without signal output wire.
- Output Logic Description
- เปิดไฟ (รุ่นนี้)
No obstruction, light path unblocked → Output ON (high level on black wire)
Object blocks light path → Output OFF
- Cross-series reference: E3T-ST24M is PNP Dark-ON with identical 300 ระยะการตรวจจับ มม
- สถานการณ์การใช้งานทั่วไป
- Presence detection & counting of materials on small production lines
- Transmittance detection for terminals, tiny parts and thin materials (minimum φ2 mm detectable)
- Installation in narrow equipment spaces (ultra-thin compact body)
- บรรจุภัณฑ์, 3C automation, lithium battery equipment, small conveyor lines
- Position limit detection, blanking presence detection
- Alternative Selection Reference within the Same Series
| แบบอย่าง | เอาท์พุต | โหมดการทำงาน | Mounting Hole | ระยะการตรวจจับ |
| E3T-ST21M | เอ็นพีเอ็น | เปิดไฟ | M3 | 300 มม |
| E3T-ST22M | เอ็นพีเอ็น | Dark-ON | M3 | 300 มม |
| E3T-ST23M | พีเอ็นพี | เปิดไฟ | M3 | 300 มม (รุ่นปัจจุบัน) |
| E3T-ST24M | พีเอ็นพี | Dark-ON | M3 | 300 มม |
ปกเกล้าเจ้าอยู่หัว. การติดตั้ง & ข้อควรระวังในการดำเนินงาน
- Emitter and receiver lenses must be coaxial aligned; misalignment will drastically reduce sensing margin
- Sensing margin curve: Only 2× margin at 300 มม; higher margin at short distances
- When multiple units are mounted side by side, stagger installation to avoid mutual interference
- Prohibit long-term oil stain and dust accumulation on lenses; clean lenses regularly
- Do not over-tighten M3 mounting screws to prevent housing cracking
- Load current shall not exceed 50 มิลลิแอมป์; direct driving of high-power solenoid valves is forbidden
OMRON E3T-ST23M Detection Accuracy / Minimum Detectable Object Specifications
- Minimum Detectable Object (Core Accuracy Index)
ข้อกำหนดอย่างเป็นทางการ: φ2 mm opaque solid object
Under standard light path at rated 300 ระยะการตรวจจับ มม, opaque objects with diameter ≥2 mm can trigger the sensor stably.
Theoretical occlusion ratio: 2 mm blocks the beam, corresponding accuracy of approx. 0.67% relative to effective beam diameter
- Beam Spot Size (Affects Fine Detection Accuracy)
Transmitting divergence angle: 2°~20°, spot diameter approx. 6~8 mm at 300 ระยะการตรวจจับ มม
Light intensity peaks at the spot center with reduced edge sensitivity; tiny workpieces smaller than 2 mm will be missed
- Repeat Positioning Accuracy (Switch Repeat Error)
เวลาตอบสนอง 1 ms with zero mechanical clearance inside the photoelectric sensor; electrical repeatability:
Trigger repeat error <0.01 mm (stable static detection)
Under high-speed dynamic conveying conditions, accuracy is determined by conveying speed; no inherent lag error from the sensor itself
- Edge Fine Detection Explanation
- Only suitable for presence detection, counting and position limit control, not for high-precision dimensional measurement;
- This model lacks sufficient accuracy for detecting tiny 0.5~1 mm parts; select E3T-SL series narrow-beam through-beam or fiber optic sensors instead;
- Thin transparent films and semi-transparent materials: ที่ 2 mm standard does not apply, unstable detection will occur for light-transmitting workpieces.
- Accuracy Limitations in Application
Misalignment error: Offset over 1 mm between emitter and receiver enlarges effective detectable diameter and degrades accuracy;
Dust and lens dirt equivalently expand the spot size, increasing minimum detectable dimension and worsening accuracy;
300 mm maximum sensing distance is the extreme operating condition; shorter distances (50~150 mm) deliver smaller spot size and better practical accuracy, enabling stable detection of workpieces close to 1.5 มม.
Nominal minimum detection accuracy: 2 mm opaque object (มาตรฐาน 300 ระยะห่าง มม)
Accuracy can be improved to approx. 1.5 mm with short-distance mounting;
Not applicable for micron-level dimensional measurement; only for workpiece presence detection.
Full Sensing Distance Specifications of OMRON E3T-ST23M
- Rated Standard Sensing Distance (Official Nominal Value)
300 มม (0.3 ม)
It belongs to short-range through-beam type in E3T-ST2 series; หลัก “2” in model code represents 300 mm specification.
- Valid Operating Range
Minimum installable distance: 5 มม (emitter and receiver cannot be tightly attached to avoid light path saturation)
Standard rated distance: 300 มม (optimal design installation distance with green stability indicator steadily lit)
Maximum detectable limit: Light margin decays rapidly beyond 300 มม; installation over 400 mm is highly susceptible to interference from dust, misalignment and vibration, long-term use is not recommended
Curve Description:
Only approx. 2× stability margin at 300 มม, just meeting the lower limit of stable detection;
Sufficient margin within 0~200 mm short range, delivering stronger anti-interference and anti-offset performance.
- Sensing Distance Classification for Same-Series Through-Beam Models (การอ้างอิงการเลือกด่วน)
| ซีรี่ส์โมเดล | ระยะการตรวจจับที่ได้รับการจัดอันดับ |
| E3T-ST1□M | 100 มม |
| E3T-ST2□M (including ST23M) | 300 มม |
| E3T-ST3□M | 2000 มม (2 ม) |
- Distance Application Notes
- 300 mm is the rated maximum limit; prioritize installation at 50~200 mm on-site for drastically improved detection stability;
- Shorten installation distance for scenarios with multiple side-by-side sensors, heavy dust environment or severe equipment vibration;
- Installation beyond 300 mm causes missed detection of tiny φ2 mm workpieces and increases the minimum detectable dimension.
Temperature Specifications of OMRON E3T-ST23M (Official Datasheet)
- อุณหภูมิในการทำงาน (Powered Running)
-25 ℃~ +55 ℃
Constraints: Environment free of icing and condensation; frost or condensation will cause lens light path failure and internal circuit short-circuit damage.
- พื้นที่จัดเก็บ / อุณหภูมิการขนส่ง (ปิดเครื่อง)
-40 ℃~ +70 ℃
Storage under icing or condensation environments is also prohibited.
Supporting Humidity Reference
Operating humidity: 35%~85% RH (ไม่มีการควบแน่น)
Storage humidity: 35%~95% ความชื้นสัมพัทธ์ (ไม่มีการควบแน่น)
On-Site Usage Notes
- For high-temperature operating conditions (>50 ℃), shorten sensing distance and reduce load current to avoid thermal drift of the sensor;
- Under low-temperature conditions (<-20 ℃), avoid rapid cold-hot alternation of equipment to prevent lens frosting;
- Long-term use of this model is not recommended near heating furnaces and ovens with high ambient temperatures; dedicated high-temperature resistant photoelectric sensors shall be adopted instead.
Translation Standard Note
All terminology follows Omron global official datasheet industrial English standards, unified international photoelectric sensor industry vocabulary, consistent with European & American automation equipment documentation writing norms.
คอนแทคเตอร์,เบรกเกอร์,อินเวอร์เตอร์พลังงานแสงอาทิตย์,มิเตอร์ไฟฟ้า,แบตเตอรี่พลังงานแสงอาทิตย์














NH42-63-318x560.png)