كارلو جافازي VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)

كارلو جافازي VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)

الجزء النموذجيوصف
VNYسلسلة المنتجات: Conductive level probe; VNY series features threaded connection with PBTP housing and non-insulated electrodes
4Electrode quantity: 4 electrodes, supporting multi-level monitoring (عالي / واسطة / قليل / منخفضة للغاية)
ن.سElectrode type: Non-Isolated, suitable for general conductive liquid measurement
NTنوع الاتصال: Screw terminals, convenient for field wiring
481046Global unique item / order number, official Carlo Gavazzi part identifier
  1. Full Core Technical Specifications
فئة المعلمةتحديدملاحظات
Basic InfoConductive level sensor for multi-point level control of conductive liquidsMust be used with amplifier relays (SV series, S195/196, ELA/ELC/ELD)
رقم الطلب.481046 (corresponds to model VNY 4 NS/NT)Order strictly by this part number
الشركة المصنعةكارلو جافازيWell-known brand in industrial automation sensors
Electrode Configuration4 non-insulated electrodes, AISI316 stainless steel (DIN1.4401)Diameter 5mm, standard length 100cm (field-cuttable)
مواد الإسكانPBTP engineering plasticCorrosion-resistant for industrial environments
نوع التركيب1 1/2″ pipe thread (ISO 228/1-G1 1/2″)Standard industrial pipeline mounting, fixed with VM15 nut
طريقة الاتصالScrew terminal connection (NT)More suitable for vibrating environments than cable connection, صيانة سهلة
حماية الدخولIP67Dust-tight and waterproof, submersible in liquid
درجة حرارة التشغيل0°C ~ 90°C (32°F ~ 194°F)Compatible with most industrial liquid temperature ranges
درجة حرارة التخزين-25°C ~ 100°C (-13°F ~ 212°F)Adaptable to extreme transportation and storage conditions
Working Pressure10 حاجِز (@ 60°C)Suitable for medium and high-pressure tank applications
مواصفات الكابلNo built-in cable (screw terminal type)Customer-supplied cable recommended; shielded cable preferred to reduce interference
الشهاداتشهادة CE (متوافق مع IEC 529)Meets EU industrial safety requirements
أبعادElectrode diameter 5mm, total length approx. 100cmElectrode length can be cut on-site according to actual liquid level
وزنتقريبا. 0.8كجمLightweight design for easy installation and maintenance
  1. VNY Series Full Model List
Item No.نموذجElectrode QtyElectrode Typeنوع الاتصالمواد الإسكانMounting ThreadSpecial Features
481046VNY 4 NS/NT4Non-Isolated (ن.س)Screw Terminal (NT)PBTP1 1/2″Multi-level control, general industrial use
481043VNY 1 NS/NT1Non-Isolated (ن.س)Screw Terminal (NT)PBTP1 1/2″Single-point level detection, فعالة من حيث التكلفة
481044VNY 2 NS/NT2Non-Isolated (ن.س)Screw Terminal (NT)PBTP1 1/2″Two-point high/low level control
481045VNY 3 NS/NT3Non-Isolated (ن.س)Screw Terminal (NT)PBTP1 1/2″Three-point high/medium/low level control
481047VNYI 4 IS/NT4Insulated (IS)Screw Terminal (NT)PBTP1 1/2″PE insulated electrodes, anti-clinging liquid interference
481042VNY 1 NS/CB1Non-Isolated (ن.س)Cable Connection (سي بي)PBTP1 1/2″2m fixed cable length, suitable for long-distance installation
  1. استبدال & Cross Reference

4.1 Same Brand Direct Replacement

النموذج الأصلينموذج الاستبدالReplacement Descriptionسيناريو التطبيق
VNY 4 NS/NT (481046)VNYI 4 IS/NTUpgraded insulated electrodes to avoid false triggering from liquid clingingViscous liquids and wall-adhering media (syrup, lubricating oil)
VNY 4 NS/NT (481046)VNY 4 NS/CBChanged to cable connection for heavy vibration environmentsLevel monitoring for vibrating equipment such as pump sets and compressors
VNY 4 NS/NT (481046)VN 4 NS/CBCable type with PBTP housing and 1 1/2″ خيطGeneral industrial environments, better cost performance

4.2 Cross-Brand Equivalent Models

كارلو جافازيشنايدراومرونPepperl+Fuchsالاختلافات الرئيسية
VNY 4 NS/NT (481046)XPSAK3711D4CC-4000FTL20-0020Carlo Gavazzi adopts superior AISI316 material with IP67 protection
Schneider higher integration; Omron more cost-competitive
Field-cuttable electrode length for better adaptability
Pepperl+Fuchs suitable for explosion-proof areas; Carlo Gavazzi for general industry
  1. Application Industries & الحالات النموذجية

Recommended Applications

  1. Process Industry: Tank level monitoring in chemical, petrochemical and pharmaceutical industries to prevent overflow and dry running
  2. Food & Beverage: Raw material and finished tank level control for beer, beverage and dairy production lines
  3. معالجة المياه: Level monitoring for sedimentation tanks and reaction tanks in waterworks and wastewater plants
  4. Energy Sector: Level protection for cooling and lubrication systems in power plants and substations
  5. Mechanical Manufacturing: Oil level monitoring for hydraulic and lubrication systems to avoid equipment damage
  6. Marine Industry: Level measurement for ship ballast tanks, fuel tanks and fresh water tanks

 

حالات التطبيق النموذجية

  1. Chemical Plant Acid & Alkali Tank Level Control System

Application Goal: Monitor high/low levels of three 100m³ acid and alkali tanks to prevent overflow and pump dry running

المزايا الأساسية: AISI316 corrosion-resistant electrodes; IP67 suitable for outdoor installation; 4-electrode enables multi-point level monitoring

System Configuration: VNY 4 NS/NT (481046) × 3 + ELA amplifier relay + PLC control system + HMI touch screen

Operation Effect: Level control accuracy ±1cm, false alarm rate reduced by 95%, maintenance cost cut by 60%

 

  1. Automobile Factory Hydraulic Station Oil Level Monitoring System

Application Goal: Monitor oil levels of 5 hydraulic stations to ensure stable operation and prevent oil shortage failure

المزايا الأساسية: Vibration-resistant screw terminal design; oil-resistant PBTP housing; field-cuttable electrodes adaptable to various tank heights

System Configuration: VNY 4 NS/NT (481046) × 5 + S196 amplifier + indicator light + buzzer

Operation Effect: Equipment failure rate reduced by 40%, maintenance cycle doubled

Not Recommended Applications

Non-conductive liquids: Such as pure oil, alcohol, acetone; not detectable by conductive sensors

ارتفاع درجة الحرارة >90درجة مئوية: Adopt VPP series (up to 100°C) or high-temperature versions

Working pressure >10 حاجِز: Special high-pressure level sensor required

Strong corrosive media: Concentrated hydrochloric acid, concentrated sulfuric acid; use VPP series with PVDF electrodes or anti-corrosion coated models

  1. تثبيت & Wiring Guidelines

متطلبات التثبيت

  1. موقف التركيب: Install on tank top or side, away from inlet ports and agitators; ensure vertical electrode immersion
  2. Electrode Cutting: Cut electrode length on-site according to actual liquid level; deburr the end after cutting for accuracy
  3. Sealing: Use suitable gaskets (PTFE recommended) for leak-tight installation to maintain IP67 protection
  4. Earthing Requirement: Conductive tank body can serve as common electrode; non-conductive tanks require separate common electrode grounding
  5. Spacing Requirement: Keep ≥50mm between electrodes and between electrodes and tank wall to avoid signal interference

Core Terminal Definition

رقم المحطة.وظيفةيكتبملاحظات
E1/E2/E3/E4Electrode 1–4Signal InputCorrespond to four level detection points; freely assign high/medium/low functions
كومCommon TerminalSignal ReferenceConnect to tank wall or separate common electrode to complete circuit
+V/-Vمزود الطاقة24VDCRequires matching amplifier relay; sensor itself needs no independent power supply
NO/NC/COMتتابع الإخراجSwitch ContactProvided by amplifier relay for valve control or alarm output

Commissioning Key Points

  1. Electrode Setting: Define corresponding level heights for each electrode (على سبيل المثال. E1=Low, E2=Medium, E3=High, E4=Ultra-high)
  2. Sensitivity Adjustment: Adjust amplifier relay sensitivity to avoid false triggering caused by foam or clinging liquid
  3. اختبار الوظيفة: Simulate level changes to verify accurate switching action and response time
  4. Insulation Check: For non-insulated type, ensure no short circuit between electrodes and tank wall; check insulation integrity for insulated type
  5. Environmental Adaptation Test: Verify long-term stability within rated temperature and pressure range
  6. Selection Rules & مرجع سريع

إرشادات الاختيار

  1. Liquid Type: Choose VNY series for conductive liquids; use capacitive or ultrasonic sensors for non-conductive liquids
  2. Electrode Quantity: 1=single point, 2=high/low, 3=high/medium/low, 4=four-point full control
  3. Electrode Insulation: NS for normal liquids; IS insulated type for viscous wall-adhering media
  4. نوع الاتصال: NT screw terminal for vibration environments; CB cable type for long-distance installation
  5. Mounting Thread: 1 1/2″ for large tanks, 1″ for medium, 1/2″ for small containers
  6. درجة حرارة & Pressure: VNY for 0–90°C / 10 حاجِز; VPP for higher temperature; special models for higher pressure
  7. Air Freight Compliance & الشهادات

Air Freight Compliance: No lithium battery / supercapacitor. Pure mechanical and metallic structure, compliant with IATA DGR Class 9, shippable as standard general cargo.

الشهادات:

– م: متوافق مع IEC 529 ingress protection standard

RoHS: EU RoHS compliant, free of hazardous heavy metals

Material Certification: AISI316 stainless steel electrodes meet food-contact grade requirements for food & beverage industry

Environmental Compliance: Compliant with REACH regulations for global market access

  1. شراء & Logistics Information
Purchase Itemتفاصيل
MOQ1 وحدة
Lead TimeStandard 5–7 days; Express 2–3 days
التعبئة والتغليفIndividual carton with installation manual, sealing gasket and mounting nut
ضمان12 months from commissioning acceptance
Recommended SparesSame model sensor, electrode extension joint (VD1), تصاعد الجوز (VM15)
Matching AccessoriesCarlo Gavazzi ELA/ELC/ELD amplifier relay, بلك, HMI touch screen