Emerson Rosemount 6R8HCI-58-C Platinum Resistance Temperature Sensor (الحق في التنمية) PDF
6R8HCI-58-C is a combined model of Emerson Rosemount 68 Series Single-Element Platinum RTD Temperature Sensor and 58C Series Cut-to-Fit Sheath. It is specially designed for industrial process temperature measurement, adopting a Pt100 thin-film element with multiple mounting options. Suitable for the temperature range of -58°F to 392°F (-50°C to 200°C).
- تعريف الجزء النموذجي
| شريحة | معنى | وصف تفصيلي |
| 6 | Sensor Series | 68 Series single-element RTD (6 = single-element; 8 = thin-film type) |
| R8 | مقاومة & فئة الدقة | R = 100Ω (Pt100); 8 = Class B accuracy (±0.3°C @ 0°C) |
| ح | مادة غمد | H = 316 الفولاذ المقاوم للصدأ (Standard SST), corrosion-resistant for most industrial environments |
| ج | Connection Head Type | C = Polypropylene connection head, excellent insulation and chemical corrosion resistance |
| أنا | Lead Configuration | I = 3-wire system, effectively compensates lead wire resistance and improves measurement accuracy |
| -58 | نطاق درجة الحرارة | -58°F to 392°F (-50°C to 200°C), matched with 58C series sheath |
| -ج | Sheath Series | 58C Series Cut-to-Fit sheath; length can be trimmed with standard pipe cutters on site |
- معلمات المواصفات الأساسية
| فئة المعلمة | Technical Index | ملاحظات |
| Basic Characteristics | ||
| نوع المنتج | Single-element Platinum Resistance Temperature Sensor (الحق في التنمية) | 68 Series thin-film type, 58C Series cut-to-fit sheath |
| ماركة | Emerson Rosemount | Benchmark brand in industrial process measurement |
| Resistance Element | Pt100 (100Ω @ 0°C) thin-film type | Fast response and high long-term stability |
| فئة الدقة | الفئة ب (اللجنة الانتخابية المستقلة 60751) | ±0.3°C @ 0°C, ±0.004°C/°C above 0°C |
| نطاق درجة الحرارة | -58°F to 392°F (-50°C to 200°C) | Temperature limit of 58C series sheath |
| المواصفات الكهربائية | ||
| Lead Configuration | 3-wire | Eliminates lead resistance influence and improves measuring accuracy |
| Lead Material | PTFE insulated, silver-plated copper, 24AWG stranded wire | Temperature resistant, chemical resistant and high conductivity |
| مقاومة العزل | ≥1000MΩ @ 500Vdc (room temperature) | Ensures integrity of measurement signal |
| وقت الاستجابة | 12 ثواني (63.2% response in 3ft/s water flow) | Fast response for thin-film element |
| المواصفات المادية | ||
| مادة غمد | 316 الفولاذ المقاوم للصدأ | High corrosion resistance and mechanical strength |
| Sheath Diameter | 0.25 inch (6.35مم) | الحجم القياسي, compatible with most thermowells |
| Sheath Length | Standard lengths: 12″, 24″, 36″, 48″ | Trimmable to any length, no need to stock multiple sizes |
| Connection Head Material | Polypropylene | Superior insulation and chemical resistance |
| Terminal Design | 6-terminal configuration | Easy wiring and compatible with various transmitters |
| الظروف البيئية | ||
| درجة حرارة التشغيل | -58°F to 392°F (-50°C to 200°C) | Limited by 58C sheath temperature rating |
| Humidity Resistance | 100% الرطوبة النسبية | Lead sealing withstands high-humidity environments |
| مقاومة الاهتزاز | ±0.05% maximum ice-point resistance drift | Compliant with industrial vibration requirements |
| حماية الدخول | IP65 | Connection head protected against dust and water intrusion |
| الشهادات & المعايير | ||
| Main Standards | اللجنة الانتخابية المستقلة 60751, ANSI MC96.1 | Globally recognized temperature sensor standards |
| علامات التصديق | م, أول, وكالة الفضاء الكندية | Compliant with international safety regulations |
- قائمة الملحقات & Mounting Parts
| Part Name | مواصفة | وظيفة | سيناريو التطبيق |
| 58C Sheath | Cut-to-fit stainless steel sheath | Protects sensor element and provides mechanical support | General industrial process temperature measurement |
| Polypropylene Connection Head | Insulated type | Provides electrical connection and environmental protection | Corrosive environments & high insulation requirements |
| 3-Wire Lead Assembly | PTFE insulated silver-plated copper wire | Transmits temperature signal with 3-wire resistance compensation | High-precision temperature measurement |
| Heat Shrink Tubing | Insulation protective sleeve | Seals and protects lead-to-sensor joint | On-site installation for enhanced tightness |
| Installation Manual | Operation guideline | Detailed installation procedures and precautions | Field installation guidance |
| Temperature Calibration Certificate | Calibration report | Provides sensor accuracy and calibration data | Quality traceability and ISO compliance |
| Mounting Fittings | Compression fitting / Spring-loaded fitting | Fixes sensor inside thermowell | Adapt to different mounting methods |
- منافس & Cross-Brand Equivalent Models
| ماركة | نموذج الاستبدال | Similar Features | الاختلافات |
| ايه بي بي | TSP400-100-B-3-0.25 | Pt100, الفئة ب, 3-wire, 0.25″ sheath | Different head material, slightly lower price |
| سيمنز | 7NG3211-0NN00 | Pt100, الفئة ب, 3-wire, stainless steel sheath | Slightly slower response time (~15s) |
| Yokogawa | TR10-100B-3-025 | Pt100, الفئة ب, 3-wire, 0.25″ sheath | Same temperature range, slightly higher calibration accuracy |
| Rosemount Internal Alternative | 7R8HCI-58-C | Pt100, الفئة أ, 3-wire, 316SST sheath | Class A accuracy (±0.15°C @ 0°C), تكلفة أعلى |
| Rosemount Internal Alternative | 6R8HPI-58-C | Pt100, الفئة ب, 3-wire, Hastelloy sheath | Stronger corrosion resistance for harsh chemical environments |
- إرشادات الاختيار & Replacement Solutions
5.1 Key Selection Parameters
| المعلمة | اختيار النقاط الرئيسية | Recommended Specification |
| فئة الدقة | Select according to measurement requirements; Class B for most industrial applications | الفئة ب (±0.3°C); High-precision use Class A (±0.15°C) |
| Lead Configuration | 3-wire compensates lead resistance; 4-wire for highest accuracy | 3-wire (معيار); 4-wire for laboratory & precision measurement |
| مادة غمد | 316SST for general environments; Hastelloy for heavy corrosion | 316SST (معيار); Hastelloy for chemical industry |
| Connection Head Material | Polypropylene for insulation; Aluminum for heat dissipation; Stainless steel for corrosion resistance | Polypropylene for corrosive sites; Aluminum for high-temperature sites |
| نطاق درجة الحرارة | 58C Series: -50°C~200°C; 68 Standard Series: -50°C~400°C | 58C for general industry; 68 standard sheath for high temperature |
| Sheath Length | 58C cut-to-fit design, no need for multiple inventory lengths | Choose standard length by insertion depth (12″/24″/36″/48″) |
5.2 توصيات الاستبدال
Insufficient temperature range: Adopt 68 standard sheath model 6R8HCI-68, range extended to -50°C~400°C
Higher accuracy required: Select 7R8HCI-58-C (Class A accuracy, ±0.15°C @ 0°C)
Severe corrosion environment: Use 6R8HPI-58-C (Hastelloy) or 6R8HCI-58-T (Titanium) sheath
Faster response required: Choose 68Q fast-response series, response time reduced to 5 ثواني
4-wire measurement needed: Select 6R8HCW-58-C to eliminate all lead resistance error
5.3 Application Precautions
- Trim the 58C sheath to required length with a standard pipe cutter before installation; reserve sufficient length for connection head assembly.
- Keep three lead wires equal in length for optimal resistance compensation in 3-wire connection.
- Avoid long-term operation above 392°F (200درجة مئوية), exceeding the 58C sheath temperature limit.
- Ensure full contact between sensor tip and thermowell bottom during installation to minimize measurement error.
- Regularly inspect connection head sealing to prevent moisture ingress and accuracy drift.
- When matched with temperature transmitters (على سبيل المثال. Rosemount 3144S), correctly configure sensor type and parameters in the transmitter.
- سيناريوهات التطبيق النموذجية
Chemical process temperature measurement (corrosive environments; polypropylene head provides reliable insulation)
Food & beverage industry (316 stainless steel complies with sanitary standards; cut-to-fit length adapts to various equipment)
Water treatment systems (chlorine corrosion resistance; 3-wire design ensures stable accuracy)
أنظمة التدفئة والتهوية وتكييف الهواء (matched temperature range and flexible installation)
Pharmaceutical industry (high-precision measurement compliant with GMP requirements)
Power industry (محول & generator winding temperature monitoring; 3-wire compensates cable resistance)
Oil & gas industry (pipeline and storage tank temperature measurement with corrosion-resistant sheath)
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية