TE Connectivity RAYCHEM POLT 3XIH1-L12A

3XIH1-L12A is the specification code of TE Connectivity RAYCHEM brand POLT series ≤12kV 3-core heat-shrink power cable terminal. The complete model is usually marked as POLT-12D/3XIH1-L12A. It is suitable for outdoor terminal installation of polymer insulated power cables such as Cross-Linked Polyethylene (XLPE) and Polyethylene (بي), providing reliable electrical insulation and environmental protection.

TE Connectivity RAYCHEM POLT 3XIH1-L12A Heat-Shrink Power Cable Terminal

3XIH1-L12A is the specification code of TE Connectivity RAYCHEM brand POLT series ≤12kV 3-core heat-shrink power cable terminal. The complete model is usually marked as POLT-12D/3XIH1-L12A. It is suitable for outdoor terminal installation of polymer insulated power cables such as Cross-Linked Polyethylene (XLPE) and Polyethylene (بي), providing reliable electrical insulation and environmental protection.

  1. تعريف الجزء النموذجي
شريحةمعنىوصف
3Cable Core NumberSpecially for 3-core cables
XInsulation TypeSuitable for polymer insulated cables (XLPE/PE/EPR)
IH1Shield Type & مواصفات الحجمIH = Copper Wire Shield; 1 = Conductor cross-section 70-120mm²
L12Aفئة الجهد & نوع التركيبL12 = Rated voltage ≤12kV; A = Standard outdoor terminal
POLT-12Dسلسلة المنتجاتPOLT = RAYCHEM heat-shrink power cable terminal series; 12D = 12kV outdoor type
  1. معلمات المواصفات الأساسية
فئة المعلمةTechnical Indexملاحظات
Basic Characteristics
نوع المنتجHeat-shrink Power Cable TerminalOutdoor installation, polymer insulation system
ماركةTE Connectivity RAYCHEMPOLT series, industry standard product
Applicable Cable Type3-core polymer insulated power cableInsulation material: XLPE, بي, EPR, إلخ.
الجهد المقنن≤12kV (U0/U=8.7/15kV)متوافق مع IEC 60502-2
Cable Shield TypeCopper Wire ShieldNot applicable for copper tape shielded cables
Conductor Specification
Applicable Conductor Section70-120مم²Copper conductor
Conductor Outer Diameter14.0-22.0ممSingle core conductor diameter
Insulation Outer Diameter25.0-35.0ممSingle core insulation diameter
Overall Cable Outer Diameter55.0-75.0ممOuter diameter of complete 3-core cable
الخصائص البدنية
Total Terminal Length450ممStandard outdoor type length
Material CompositionCross-linked Polyolefin Heat-shrink MaterialWeather resistance, مقاومة للأشعة فوق البنفسجية, aging resistance
لونBlackIndustrial standard color, anti-UV
طريقة التثبيتHeat shrink installationSpecial heating tool required (≥300℃)
الظروف البيئية
درجة حرارة التشغيل-40°C ~ +90°Cنطاق درجة حرارة واسعة, مناسبة للبيئات القاسية
حماية الدخولIP68Fully dustproof and waterproof, operable under immersion
Weather Resistanceمتوافق مع IEC 60811-3-1مقاومة للأشعة فوق البنفسجية, ozone resistance, chemical corrosion resistance
الأداء الكهربائي
مقاومة العزل≥10¹⁴ΩNormal condition, ensure excellent insulation performance
قوة عازلة≥45kV/1minBreakdown strength of terminal insulation layer
Partial Discharge≤10pCUnder 1.73U0 voltage, maintain low partial discharge level
Creepage Distance630ممMeet pollution level requirements for 12kV class
  1. قائمة الملحقات & Mounting Parts
رقم الجزء.اسموظيفةQ’ty
3XIH1-L12A Main KitHeat-shrink Tube AssemblyProvide insulation, sealing and stress control1 Set
Stress Control TubeNon-linear Heat-shrink TubeUniform electric field distribution, eliminate electric stress concentration3 جهاز كمبيوتر شخصى (1 per core)
Insulation TubeMain Insulation Heat-shrink TubeMain insulation protection1 pc (ل 3 cores)
Sealing TubeWaterproof Sealing Heat-shrink TubeSeal the joint between cable outer sheath and terminal1 pc
ShedAnti-pollution Flashover Heat-shrink ShedIncrease creepage distance and anti-fouling performance3 جهاز كمبيوتر شخصى
Copper Mesh / Grounding WireShield Grounding WireGround connection for cable shielding layer1 Set
Filling MasticInsulation Filling MaterialFill gaps between cores, improve insulation performance1 pc
Cleaning Cloth / SandpaperSurface Treatment ToolsClean cable insulation surface, improve adhesion1 Set
Installation ManualOperation GuideDetailed installation steps and precautions1 Copy
  1. منافس & ما يعادلها عبر العلامات التجارية
ماركةنموذج الاستبدالSimilar Featuresالاختلافات
ايه بي بيAPIT-12/3-70-12012kV 3-core, 70-120مم, copper wire shieldCold-shrink technology, no heating required, تكلفة أعلى
5623P-1212kV 3-core, 70-120مم, copper wire shieldCold-shrink type, تركيب سهل, permanent elasticity
ChangyuanWS-12/3.212kV 3-core, 70-120مم, copper wire shieldHeat-shrink type, فعالة من حيث التكلفة, high domestic market share
WalsinWRS-12/3-70-12012kV 3-core, 70-120مم, copper wire shieldHeat-shrink type, material performance close to RAYCHEM
RAYCHEM Internal Replacement3XIH4-L12A12kV 3-core, 150-240مم, copper wire shieldFor larger conductor section, same terminal length
  1. إرشادات الاختيار & Replacement Solutions

5.1 Key Selection Parameters

المعلمةاختيار النقاط الرئيسيةRecommended Standard
مطابقة الجهدMust match cable rated voltage12kV terminal for 8.7/15kV cable; not for higher voltage class
Core NumberTerminal core number shall be consistent with cable3-core terminal only for 3-core cable, not for single-core or 4-core
Conductor SectionTerminal range must cover cable conductor section70-120mm² terminal applicable to 70、95、120mm² cables
Shield TypeTerminal must match cable shield typeIH for copper wire shield; OH for copper tape shield
بيئة التثبيتL type for outdoor; I type for indoorOutdoor site must adopt L type with sheds

5.2 توصيات الاستبدال

Mismatched conductor section: Select corresponding range model, على سبيل المثال. 150-240mm² use 3XIH4-L12A

Different shield type: Copper tape shield cable adopt 3XOH1-L12A

Indoor installation: Choose 3XIH1-I12A (without sheds)

Easier installation requirement: Adopt RAYCHEM cold-shrink terminal (RST series), no heating tool needed

5.3 Application Precautions

  1. Check cable insulation condition before installation to ensure no damage and no moisture.
  2. Strictly follow installation manual; control heating temperature at 300-350℃ and heating time.
  3. Clean and polish core insulation surface tightly to ensure close fitting of heat-shrink tube.
  4. Reliably connect shielding grounding wire to guarantee electrical safety.
  5. Perform insulation test and partial discharge test after installation; put into operation only after qualified.
  6. Applicable for overhead, tunnel, cable trench and other outdoor / semi-outdoor occasions; not suitable for underwater use.
  7. سيناريوهات التطبيق النموذجية

10kV/12kV distribution line outdoor cable terminals

12kV cable outgoing terminals of substation & switch station

12kV internal power distribution cable terminals for industrial enterprises

12kV cable terminals for new energy projects such as wind power & photovoltaic power generation

12kV cable terminal replacement & renovation of urban power grid

السابق:

التالي:

ترك الرد

ترك رسالة