ب&R 0AC808.9 8-Port Industrial Layer 2 Hub

Full Model Name & Code Definition Complete order model: 0AC808.9-1 (abbreviated as OAC808.9 in the industry) 0تكييف: ب&R automation infrastructure / network component series 808: 8-port industrial Ethernet Hub (طبقة 2 hub) .9: Hardware version identifier -1: Standard version with 24VDC power supply Original factory part number: 306071 Place of origin: Austria Core Network Specifications ...

  • تفاصيل المنتج

Full Model Name & Code Definition

Complete order model: 0AC808.9-1 (abbreviated as OAC808.9 in the industry)

  1. 0تكييف: ب&R automation infrastructure / network component series
  2. 808: 8-port industrial Ethernet Hub (طبقة 2 hub)
  3. .9: Hardware version identifier
  4. -1: Standard version with 24VDC power supply

Original factory part number: 306071

Place of origin: النمسا

  1. Core Network Specifications (طبقة 2 Hub, التبديل غير المدارة)
عنصر المعلمةالمواصفات الفنية
Number of Ports8 shielded RJ45 Ethernet ports
Transmission Rate10/100 Mbps auto-adaptive, auto-negotiation
Cable CompatibilityAuto-MDI/MDIX, compatible with straight-through & crossover cables
Maximum Transmission Distance100 m per segment (industrial shielded twisted pair cable)
Forwarding Latency0.64~0.68 渭s; low latency compatible with POWERLINK real-time bus
Port IsolationElectrical isolation between all ports; isolation between ports, power supply and ground
Network Layerطبقة 2 shared hub (single broadcast domain)
Supported ProtocolsStandard Ethernet, إيثرنت سريع, POWERLINK

LED Status Indicators (Independent for Each Channel)

  1. Orange RX: Data transmit/receive activity indicator
  2. Green/Red L/C: Green = Link normal; Red = Collision detected
  3. Orange OK: Global 24V power supply status indicator
  4. Electrical Power Specifications
  5. جهد الإمداد: 18~30 VDC (standard industrial 24 VDC)
  6. Max Operating Current: 150 أماه
  7. Total Power Consumption: ≥ 3 دبليو
  8. Power Protection: Built-in reverse polarity protection diode; no overvoltage protection. A 24V stabilized power supply must be deployed upstream.
  9. أسلاك الطاقة: Terminal block 0TB704.9 must be purchased separately (not included as standard; mandatory accessory)
  10. ميكانيكية & أبعاد التركيب

عرض 115 mm × Height 43 مم (51 mm with DIN rail mounted) × Depth 86 مم

طريقة التركيب: معيار 35 تركيب السكك الحديدية مم DIN (DIN rail clip pre-installed); supports horizontal & vertical cabinet installation

فئة الحماية: IP20 (استخدام الخزانة الداخلية فقط)

درجة الحرارة المحيطة & رطوبة:

درجة حرارة التشغيل: -25درجه مئوية ~ +60 درجه مئوية (valid for both horizontal and vertical mounting)

تخزين & درجة حرارة النقل: -40درجه مئوية ~ +85 درجه مئوية

رطوبة: 5%~95% رطوبة نسبية, غير التكثيف

  1. الشهادات & Industrial Compatibility

Compliance Certifications: م, cULus E115267, ABS marine certification

Anti-Interference: Compliant with industrial EMC standards, suitable for control cabinets of machine tools, اللوجستية, packaging and new energy equipment

Housing: Metal enclosure with excellent electromagnetic shielding performance

  1. معيار & Mandatory Optional Accessories
  2. Included upon delivery: DIN rail mounting clip, hub main unit
  3. Must be ordered separately (not supplied with main unit):

0TB704.9: 4-pin power terminal block (24الخامس+, 0V, reserved functional pins)

  1. الملحقات الاختيارية: Shielded RJ45 industrial Ethernet cables, EMC grounding terminals
  2. مبدأ التشغيل & Networking Features
  3. Working Principle of Layer 2 Shared Hub

الجميع 8 ports share one single broadcast domain. Data transmitted or received via any port will be broadcast and forwarded to the other 7 الموانئ. It has no VLAN, port isolation or routing functions and belongs to shared-bandwidth equipment.

  1. POWERLINK Real-Time Bus Compatibility

Ultra-low forwarding latency, specially designed for B&R POWERLINK motion control bus to expand real-time nodes including PLCs, servo drives and remote I/O stations.

  1. Advantages of Electrical Isolation

Each port is isolated by built-in transformers to avoid bus interference and port burnout caused by ground potential differences between different devices.

  1. سيناريوهات التطبيق النموذجية
  2. Extension of slave stations for B&R POWERLINK motion control systems (networking of multiple servo drives / remote I/O modules)
  3. Ethernet distribution inside control cabinets for machine tools, injection molding machines and packaging machinery
  4. Simple network expansion for distributed PLCs, HMI touch panels and machine vision cameras on production lines
  5. Aggregation of multi-node Ethernet signals for marine and vehicle-mounted industrial control equipment
  6. Low-cost real-time bus signal distribution for small & medium-sized automated production lines
  7. استبدال & Upgrade Options within the Same Series
  8. No derivative models with identical specifications; 0AC808.9-1 is the only standard 8-port version
  9. Upgrade alternatives (managed switches): 0AC100.9, 0AC101.9 (support VLAN, port management and redundancy)
  10. البدائل عبر العلامات التجارية: 8-port unmanaged industrial hubs from MOXA / فايدمولر (latency must match POWERLINK requirements)
  11. المزايا الرئيسية & القيود

المزايا

  1. Ultra-low forwarding latency with perfect compatibility for B&R POWERLINK real-time motion bus
  2. Full-port electrical isolation to resist industrial interference and prevent damage from ground loops
  3. Wide operating temperature & نطاق الجهد, metal shielded housing, robust industrial-grade design
  4. التوصيل والتشغيل بدون تكوين; no software setup required

القيود

  1. Shared bandwidth leads to network collisions under high concurrent data transmission from multiple nodes
  2. No VLAN, port speed limit or network management functions
  3. Separate purchase of power terminals increases accessory costs for projects
  4. Not suitable for large-scale multi-device networking when heavy broadcast traffic exists

Full Application Scenarios of B&R 0AC808.9 (8-Port Industrial Hub)

Core positioning of 0AC808.9: 8-port industrial hub exclusively developed for B&R POWERLINK real-time motion bus. Featuring ultra-low forwarding latency (0.64~0.68 μs), full-port electrical isolation and DIN rail mounting, it is mainly used for Ethernet signal distribution inside cabinets of small & medium multi-axis machinery. All applicable scenarios are based on the B&R automation platform.

  1. Core Industrial Machinery Scenarios (Most Widely Used)

1.1 ماكينات التعبئة والتغليف (Largest Consumption Volume)

Vertical bag making machines, horizontal flow wrappers, carton forming machines, multi-station labeling machines, تعبئة & capping integrated machines

Networking Requirement: 1 X20 PLC host + 4~7 ACOPOS servo drives + vision cameras / HMI touch panels. When a single cabinet contains more than 5 nodes, 0AC808.9 is adopted for centralized signal distribution.

فوائد: Microsecond-level low latency ensures real-time multi-axis synchronization for electronic cam, flying shear and synchronous cutting functions; port isolation eliminates bus faults induced by ground loop currents of servo drives.

1.2 Plastic Injection & Extrusion Equipment

All-electric injection molding machines, blow molding machines, film extrusion casting lines, pipe extrusion pullers

طلب: Expand multiple POWERLINK servo axes (injection axis, mold opening/closing axis, manipulator, traction servo) inside the main cabinet, while connecting temperature control modules and human-machine interfaces.

القدرة على التكيف البيئي: نطاق درجة حرارة التشغيل واسعة (-25درجه مئوية ~ +60 درجه مئوية) and metal shielded housing resist strong electromagnetic interference from heating coils.

1.3 الطباعة & Paper-Making Equipment

High-speed flexographic printers, gravure printers, slitting & rewinding machines, cross-cut paper machines, label printing presses

Working Conditions: High-precision synchronization of dozens of axes (electronic gear, color registration correction). Multiple servo drives are concentrated in the main control cabinet and wired in star topology via 0AC808.9 to replace cumbersome daisy-chain wiring.

1.4 أدوات الآلة & Metal Processing Equipment

CNC lathes, gantry machining centers, ماكينات القطع بالليزر, stamping manipulators, metal bending machines

Networking: CNC controller + multi-axis servo drives + linear scale signal acquisition modules + operation panels for centralized cabinet wiring; resistant to EMC interference from machine tool inverters and contactors.

1.5 Textile Machinery

Warp knitting machines, circular looms, high-speed winders, nonwoven production lines

سمات: Scattered multiple servo nodes and compact cabinet space. Compact DIN rail-mounted 0AC808.9 saves installation space and supports plug-and-play without configuration.

  1. Logistics Conveying & Intelligent Sorting
  2. Pallet sorters, cross-belt sorting lines, parcel conveying lines, AGV control cabinets for automated warehouses
  3. وظائف: Aggregate conveying servo drives, barcode scanning cameras, sorting actuators and remote I/O stations. ABS marine certification allows deployment on port vehicle-mounted sorting equipment.
  4. فوائد: Wde voltage range (18~30 VDC) adapts to vehicle-mounted 24 VDC power supply and withstands shock and vibration.
  5. الطاقة الجديدة & Electronic Semiconductor Equipment
  6. Photovoltaic Equipment: Silicon wafer cutting machines, screen printers, solar cell sorters, module laminators
  7. Lithium Battery Equipment: Electrode coating, calendaring, slitting and winding integrated machines
  8. Semiconductor Equipment: آلات وضع SMT, chip inspection equipment, cleanroom assembly equipment

Adaptation Highlights: Full-port electrical isolation ensures stable operation in low-dust clean cabinets; low latency meets multi-axis synchronization with micron-level positioning accuracy.

  1. طبي & Pharmaceutical Automation Equipment
  2. Infusion set assembly lines, capsule filling machines, vial labeling machines, medical device conveying lines with ACOPOStrak flexible transport system
  3. سيناريو: Network PLCs, multiple servo drives and visual inspection cameras inside clean control cabinets. IP20 protection fits dust-free workshops, and simplified network configuration reduces commissioning workload.
  4. البحرية & Vehicle-Mounted Special Industrial Control Scenarios

Supported by ABS marine certification for the following applications:

  1. Marine deck automation control cabinets, auxiliary machinery control systems in engine rooms
  2. Mobile vehicle-mounted equipment: 24 VDC industrial control systems for engineering vehicles and mobile inspection devices

Wide temperature tolerance, metal shielding and anti-ground-loop port design adapt to harsh conditions with intense vibration and drastic temperature fluctuations.

  1. Standard Expansion Scenarios for General Control Cabinets (Matched with Full Range of B&R I/O Modules)
  2. Remote I/O station expansion for small & medium production lines: Centralized wiring for X20 remote modules, safety I/O modules and POWERLINK safety nodes
  3. Machine Vision Matching: One hub connects the controller and multiple industrial cameras to synchronously collect visual inspection data
  4. HMI Expansion for Equipment: Unified aggregation of PLCs, touch panels, remote maintenance Ethernet ports and data acquisition gateways
  5. Integrated Control Cabinets for Single Multi-Function Machines: Centralized networking of all network nodes covering motion control, logic control, machine vision and temperature regulation within one machine.
  6. Topology Application Features (Distinguished from Switches, Exclusive to Hub Scenarios)
  7. Preferred for Star-Type POWERLINK Networking: When a single cabinet contains ≤7 servo/I/O nodes, 0AC808.9 is used for star aggregation. Compared with daisy-chain topology, it reduces machine downtime risks caused by single cable failure.
  8. Not Suitable for Large-Scale Production Lines: Not recommended for systems with more than 15 real-time nodes (shared bandwidth of hubs causes increased cycle jitter due to data collisions). Upgrade to 0AC100 managed switches in such cases.
  9. Matching Restrictions: Must be used with 0TB704.9 power terminal blocks; only for IP20 indoor cabinet installation, not for direct outdoor deployment.
  10. Core Reasons for Adopting 0AC808.9 across Industries
  11. Ultra-low forwarding latency; the only industrial hub compatible with microsecond-level synchronization of POWERLINK;
  12. 8 shielded RJ45 ports with full electrical isolation solve port burnout issues caused by ground potential differences on industrial sites;
  13. Plug-and-play without configuration enables standardized factory assembly and cuts commissioning man-hours;
  14. Compact DIN rail mounting fits the limited internal space of control cabinets for small & medium machinery.

السابق:

ترك الرد

ترك رسالة