Full Order Code: IGB3008BBPKG/V4A/US-104
Hygienic M18 flush-mount inductive sensor, designed for food, pharmaceutical and washdown applications.
✅ Model Code Interpretation
اي جي: Inductive proximity sensor
ت: Hygienic V4A (316L الفولاذ المقاوم للصدأ) مسلسل, IP69K high-pressure washdown resistant
203: Ordering code
3008: M18 thread, rated sensing distance 8 مم
BBPKG: Flush mount, PNP normally open, M12 connector with A-coded gold-plated contacts
V4A: 316L stainless steel housing
US: UL certification
📋 Key Electrical Specifications
| غرض | المعلمة |
| جهد الإمداد | DC 10~30V |
| نوع الإخراج | PNP Normally Open (لا) |
| Rated Sensing Distance Sn | 8 مم, flush mount |
| Effective Operating Distance | 0~6.48 mm |
| تبديل التردد | 600 هرتز |
| Max Output Current | 100 أماه |
| عدم التحميل الحالي | <10 أماه |
| حماية | عكس حماية القطبية, pulsed short-circuit protection, حماية الزائد |
| انخفاض الجهد | ≤2.5V |
🛠 Mechanical and Environmental Specifications
السكن: M18×1 thread, overall length 45 مم
تصاعد: Flush mount capable
مواد الإسكان: 316ل (1.4404) الفولاذ المقاوم للصدأ; Sensing face PEEK; Nuts 316L stainless steel
فئة الحماية: IP68 / IP69K (Suitable for high-pressure hot water cleaning)
درجة الحرارة المحيطة: 0 ~ +100 درجه مئوية
عزم الدوران: الأعلى 50 Nm for lock nuts
اتصال: M12 4-pin A-coded gold-plated connector
مؤشر: 4 yellow LEDs for switching status indication
محتويات الحزمة: Sensor body + 2 stainless steel lock nuts
وزن: تقريبا. 44.7 ز
Target Correction Factor: Steel=1; Stainless steel=0.7; Brass=0.5; Aluminum=0.4; Copper=0.3
🎯 Application Scenarios
Hygienic production lines in food & مشروب, pharmaceutical and dairy industries requiring CIP/SIP high-pressure rinse; metal workpiece presence detection and position limit monitoring.
سمات: Resistant to cleaning agents and thermal shock, hygienic stainless steel housing with crevice-free construction, suitable for frequent washdown environments.
📌 Wiring Assignment (M12 4Pin A-coded)
- بني: DC+ (10~30 فولت)
- أزرق: DC 0V
- أسود: PNP normally open output
- Not used
⚠️ Troubleshooting Guide
- لا يوجد إخراج: تحقق من مصدر الطاقة; verify brown/blue wiring (reverse polarity protection prevents burnout but no switching action). Confirm metal target is within effective sensing range.
- اثارة كاذبة: Incorrect air gap; reduced sensing distance for aluminum/copper targets; strong electromagnetic interference from nearby equipment.
- Intermittent signal: Oxidation of M12 connector contacts (gold plating resists oxidation in humid washdown environments); loose nuts due to vibration.
- إيقاف تشغيل الصمام: Missing supply voltage or damaged sensor.
🔁 Alternative Selection Reference
نفس السلسلة: IGT200 (M18 non-flush, 12 مم); IGT204 (Normally closed version)
Domestic alternative requirements: M18 flush mount, 316L stainless steel housing, IP69K, PNP NO, موصل M12, تصنيف 8 مسافة الاستشعار ملم. ملحوظة: Most domestic sensors only reach IP67, IP69K hygienic models are limited.
📎 Supplementary Information
No IO-Link interface, digital switch output only
Flush mounting: Sensor face can be recessed into metal mounting bore for improved impact resistance
الشهادات: cULus, suitable for North American export machinery
IFM Inductive Proximity Sensor Application Cases (IGT203 Relevant)
IGT203 is a hygienic 316L stainless steel, IP69K, M18 flush inductive sensor, primarily used for food/pharma CIP washdown environments. Below are industry-based application cases including detection task, site challenges and selection guidelines.
🍞 Food, المشروبات & صناعة الأدوية (Best Fit for IGT203)
قضية 1: Safety Monitoring for Tank Access Hatch
Detection Task: Verify full closure of tank manhole / access cover. If the cover remains open, feeding and agitation are locked out to prevent personnel entry hazards.
Site Challenges: Daily CIP high-pressure hot water + acid/alkaline detergent rinse, humid and corrosive conditions, large temperature fluctuations. Standard plastic sensors degrade rapidly.
اختيار: IGT203 (316L الفولاذ المقاوم للصدأ, IP69K, chemical washdown resistant), PNP switch output, metal hatch as trigger target.
Benefit: Non-contact operation with zero mechanical wear; no seized mechanical contacts from corrosion, stable performance after high-pressure cleaning.
قضية 2: اسطوانة / Valve Position Feedback on Filling Lines
Detection Task: Detect metal target position on filling valves and actuator pistons to confirm filling head extension/retraction and trigger filling sequence logic.
Site Challenges: Frequent spray cleaning and heavy machine vibration.
اختيار: IGT203, M18 flush mounting for impact protection. Recessed installation avoids direct impact from product and cleaning jets.
ملحوظة: Sensing distance is reduced for stainless steel targets, so air gap margin must be reserved during installation.
قضية 3: Safety Position Detection for Cold Storage AGV Rapid Doors
Detection Task: Monitor metal door position of rapid cold-room doors. AGV access is blocked if door is not fully closed to prevent collision.
Site Challenges: Low temperature down to -25℃, heavy condensation and repeated door impact.
اختيار: IFM hygienic inductive sensor with wide temperature range and stainless steel housing against condensation corrosion.
⚙️ Machine Tool & Metalworking Industry
قضية 4: Tool Presence Detection on CNC Magazine
Detection Task: Detect metal tool holders in rotating magazine pockets to confirm tool availability and prevent empty-tool operation and spindle collision.
Site Challenges: Continuous spray of cutting fluid and emulsion, heavy oil mist and metal chips, persistent vibration.
اختيار: IFM IGC all-metal inductive sensor, stainless housing resistant to cutting fluid. IGT203 is not recommended here: hygienic series carries higher cost and is optimized for food washdown rather than machine tools.
Benefit: Non-contact sensing avoids jamming by metal chips compared with mechanical limit switches, greatly extending service life.
قضية 5: مغزل / Gear Speed Acquisition
Detection Task: Gear teeth pass the sensor to generate pulse signals for PLC speed calculation and overspeed protection.
Site Challenges: High switching frequency requirement, oil and dust contamination.
اختيار: High-frequency IFM inductive sensor paired with gear wheel for non-contact speed measurement.
🚗 Automotive Assembly Lines
قضية 6: Workpiece Clamping Detection on Robot Grippers
Detection Task: Confirm metal sheet metal is securely clamped by robot gripper before welding or material handling.
Site Challenges: Weld spatter, dust and mechanical vibration.
اختيار: IFM M18 inductive sensor with PTFE anti-spatter coating and flush mounting for impact protection.
IGT203 is not recommended here: PEEK sensing face cannot withstand high-temperature weld spatter.
قضية 7: Pallet Positioning & Counting on Conveyors
Detection Task: Generate stop signal for incoming metal pallets and count pallet quantity for production cycle control.
Site Challenges: High-speed continuous conveying, heavy dust and mechanical tolerance variation of pallet position.
اختيار: Standard M18 inductive sensor with sufficient sensing margin to accommodate mechanical tolerances.
🚢 Port Logistics & Heavy Machinery
قضية 8: Twistlock Position Monitoring for Container Spreaders
Detection Task: Detect fully locked / unlocked position of container spreader twistlocks. Lifting/lowering operation is permitted only after confirmed lock status to prevent container drop hazards.
Site Challenges: Coastal salt spray, rain impact and heavy vibration under heavy load.
اختيار: IFM IIS inductive sensor, some models support IO-Link for remote status reading and predictive aging warning.
قضية 9: Outrigger Extension Position Detection for Construction Machinery
Detection Task: Detect metal target on crane / aerial work platform outriggers. Lifting operation is prohibited unless outriggers are fully extended and locked, forming safety interlock signal.
Site Challenges: Outdoor wide temperature range, mud, water and gravel impact.
اختيار: IFM all-metal safety inductive sensor with TÜV safety certification.
📦 3C & Precision Assembly Industry
قضية 10: Tiny Metal Screw Counting on Vibratory Feeders
Detection Task: Ring inductive sensor detects screws and nuts passing through the pipe at high speed, counting parts and triggering jam / shortage alarms.
Site Challenges: Small workpiece size, conveying speed up to 35 m/s.
اختيار: IFM I7R ring inductive sensor with IO-Link and built-in part counter, part count available directly without PLC pulse counting.
قضية 11: Fixture Position Detection
Detection Task: Detect metal stopper clamping status of jigs, confirm fixture locking before pressing operation.
Site Challenges: Limited installation space and frequent reciprocating motion.
اختيار: Compact IFM M5/M8 inductive sensors (IY/IZ series).
✅ General Application Classification (Four Major Uses of Inductive Proximity Sensors)
- ردود الفعل الموقف: Position detection of cylinders, الصمامات, slides, safety guards and mechanical limit points, replacing mechanical limit switches with zero wear.
- Metal Workpiece Presence Check: Confirm presence of metal targets at workstations.
- عد & Flow Monitoring: Pulse counting of metal parts and pallets.
- Rotational Speed Monitoring: Speed measurement and overspeed protection using gears and cams.
📌 Summary of IGT203 Selection & طلب
✅ Preferred applications: طعام, dairy, مشروب, pharmaceutical and hygiene machinery requiring CIP/SIP high-pressure cleaning and 316L hygienic metal position detection.
❌ Not recommended: Weld spatter exposure, heavy cutting fluid, outdoor salt spray heavy machinery (تكلفة أعلى; PEEK sensing face vulnerable to weld spatter damage).
IFM Inductive Proximity Sensor Installation Guide (Focus on IGT203 M18 Hygienic Flush Model)
- التفتيش قبل التثبيت
- التحقق من النموذج: IGT203 is a flush mount recessable M18 inductive sensor, 316L stainless housing, PEEK sensing face, IP69K; supply DC10~30V, PNP normally open.
- Visual Check: Sensor body free of dents, PEEK face scratch-free; M12 connector seal intact, 2 pcs 316L lock nuts supplied.
- Site Condition Assessment
Keep clear of variable frequency drives and servo power cables to avoid electromagnetic interference and false triggering; separate signal cables and power cables.
Confirm target material: Steel is optimal; stainless steel reduces sensing distance by 0.7 مرات, aluminum by 0.4 مرات, reserve margin during selection.
Metal mounting base must have sufficient thickness; thin sheet metal causes magnetic field leakage.
- التركيب الميكانيكي (IGT203 Flush Mount)
Flush mount: Sensor sensing face sits flush with the end face of metal mounting bore, recessed into the housing for impact resistance, preferred for food washdown environments.
- Machine M18×1 threaded bore, deburr bore edge; bore depth to fully recess sensor and align sensing face flush with surface.
- Thread sensor into mounting bore, fit two stainless lock nuts (double nut anti-loosening, mandatory for vibrating machines).
- التحكم في عزم الدوران: الأعلى 50 Nm for IGT203 lock nuts. Over-torque causes thread deformation and PEEK face cracking, leading to water ingress during washdown.
- متطلبات التباعد (شديد الأهمية)
التركيب جنبًا إلى جنب: Hygienic IGT series allows closer arrangement; standard inductive sensors require spacing ≥2×sensor diameter to prevent mutual magnetic interference and false switching.
Minimum clearance between sensor sidewall and surrounding metal: ≥1.5×Sn (Sn=8 mm → ≥12 mm). Adjacent metal absorbs magnetic field, shortening sensing distance and causing unstable signals.
Target size recommendation: Target area ≥ sensor sensing face. Small targets reduce detection reliability.
Operating air gap: Rated Sn=8 mm for IGT203, max reliable operating distance ≤6.48 mm. Engineering recommendation ≤5.6 mm to avoid unstable switching near threshold.
- Installation protection: For CIP washdown, orient M12 connector downward to prevent liquid pooling at connector; reserve cable slack to avoid tension load.
✅ Flush vs Non-flush Distinction
Flush: Can be embedded into metal, impact resistant (IGT203 type)
Non-flush: Sensing head must protrude from metal surface; surrounding metal cannot enclose the sensor otherwise function is lost.
- التركيبات الكهربائية (M12 4Pin A-coded Connector for IGT203)
تعيين الدبوس:
- بني: DC+ 10~30V
- أزرق: DC 0V
- أسود: PNP normally open output (to PLC input)
- Spare pin
Wiring notes:
- 3-wire PNP: Load connected between signal wire (black) and 0V.
- Fully insert M12 connector and compress seal to maintain IP69K; inspect O-ring aging periodically for washdown machines.
- Cable bending radius ≥5×cable outer diameter; sharp bends prohibited.
- Recommend 2A fast blow fuse in supply circuit for short-circuit protection.
- Built-in reverse polarity, short-circuit and overload protection. Reverse power connection will not damage sensor but no switching output.
- خطوات التكليف
- Rough mechanical adjustment: Move metal target toward sensing face, observe yellow LED. LED ON = Metal detected.
- Fine tune air gap: Cycle target movement repeatedly to confirm stable ON when target approaches and reliable OFF when withdrawn, no flickering.
- Dynamic test: Run full machine reciprocating cycles to verify no signal loss or false triggering under operating speed.
- Thermal stabilization test: Keep sensor powered for extended run time. Some sensors require 15 minutes thermal stabilization to rule out drift.
- أخطاء التثبيت الشائعة & المخاطر
- ❌ Install flush sensor as non-flush with protruding head → risk of mechanical impact damage (critical for food lines IGT203).
- ❌ Surrounding metal too close to sensor side → reduced sensing distance and unstable signal.
- ❌ Two proximity sensors mounted tightly adjacent (standard types) → mutual magnetic interference, random false triggering.
- ❌ Excessive tightening torque → thread damage, PEEK face cracking and water ingress during washdown.
- ❌ Aluminum / copper target without reduced air gap → failure to detect workpiece.
- ❌ M12 connector oriented upward, cleaning solution accumulates in connector and corrodes gold contacts.
- إرشادات الصيانة (IGT Hygienic Series)
Withstands high-pressure CIP rinse, but avoid continuous direct high-pressure jet aimed at PEEK sensing face.
Periodically check nut tightness and M12 connector seal integrity.
Do not scratch PEEK sensing face with sharp tools, scratches degrade reliability.
- Installation Checklist (Printable for Site Technicians)
نوع التركيب: Flush, sensing face aligned flush with metal surface
Double lock nuts fitted, torque ≤50 Nm
Minimum clearance ≥12 mm between sensor side and adjacent metal
Operating air gap ≤6.48 mm, engineering preferred ≤5.6 mm
الأسلاك: Brown to 24V+, Blue to 0V, Black to PNP output
M12 connector seal intact, connector oriented downward
اختبار التشغيل: LED ON when metal approaches, OFF when removed, no flickering
IFM IGT Series (M18 Hygienic Inductive Proximity Sensors) قائمة النماذج الكاملة
IGT series = Inductive General T hygienic series, 316ل(V4A) stainless housing, IP69K, PEEK sensing face, dedicated for food/pharma CIP washdown, M18×1 thread, DC10~30V, M12 A-coded gold-plated connector, ambient temperature 0~100℃.
Main Models IGT200~IGT207 (Short body with standard connector, IGT203 in this group)
| رمز الطلب | النموذج الكامل | مسافة الاستشعار | Body Length | وصف |
| IGT200 | IGB3012-BPKG/M/ V4A/US-104-DPS | 12 مم | 51 مم | M18 non-flush, 12 مم, PNP NO, standard connector |
| IGT202 | IGKC012-ASKG/ 2LED/V4A/US-104 | 12 مم | 70 مم | Long body, optical alignment LED, 2/3 wire compatible |
| IGT203 | IGB3008BBPKG /V4A/US-104 | 8 مم | 45 مم | Model in review, recess flush mount, PNP NO, mainstream food line sensor |
| IGT204 | IGB3008BAPKG /V4A/US-104 | 8 مم | 45 مم | Normally closed variant of IGT203, identical other parameters |
| IGT205 | IGKC008-ASKG /2LED/V4A/US-104 | 8 مم | 70 مم | Long body, bipolar output, alignment aid LEDs |
| IGT206 | IGB3008BBPKG /M/V4A/6M/WH | 8 مم | 57 مم | Fixed 6m integral cable, no M12 connector |
| IGT207 | IGB3008BBPKG /M/V4A/10M/WH | 8 مم | 57 مم | Fixed 10m integral cable, no M12 connector |
IGT201: No mass-produced model, skipped part number.
Other M18 Hygienic Models in IGT Series
| رمز الطلب | النموذج الكامل | مسافة الاستشعار | نوع التركيب | نوع الإخراج | ملاحظات |
| IGT250 | IGK3012-ANKG/AM/P/US-104 | 12 مم | Non-flush | NPN NO | Long body NPN normally open variant |
| IGT261 | IGB3010-BPKG/AM/P/US-104 | 10 مم | Quasi-flush qf | PNP NO | All-metal sensing face, PEEK replaced with stainless steel face |
| IGT262 | IGB3012-BPKG/AM/P/US-104 | 12 مم | Non-flush nf | PNP NO | All-metal sensing face, end-of-life announced 31.03.2026 |
IxT Hygienic Inductive Family (Other Thread Sizes, Same Hygienic Platform as IGT)
IFT Series: M12 hygienic inductive (IFT259, IFT260)
IIT Series: M30 hygienic inductive (IIT245, IIT246)
IGT Series Model Code Decoding
- IGT: أنا(Inductive)+ز(عام)+ت(Hygienic V4A stainless series)
- 2xx: M18 body specification
- شرح اللاحقة:
BBPKG: Flush mount, PNP NO; BAPKG: Flush mount, PNP NC
ASKG: PNP/NPN switchable, with dual alignment LEDs
V4A: 316L stainless steel housing
US: UL certification for North America
/6M /10M: Fixed integral cable without M12 connector
DPS: نسخة محسنة
IGT Series Quick Selection Guide
✅ Short body + موصل M12 + Flush 8 mm NO → IGT203 (السائدة)
✅ Short body + موصل M12 + Flush 8 mm NC → IGT204
✅ Long body, PNP/NPN field selectable → IGT202 / IGT205
✅ Fixed long cable instead of M12 connector → IGT206 (6م), IGT207 (10م)
✅ Stainless steel sensing face (no PEEK), improved abrasion resistance → IGT261, IGT262 (262 توقف)
✅ NPN output required → IGT250
Compatible Accessories List
EVC series: M12 4-core A-cable, مستقيم / 90° موصل الكوع
E21327, E21328: Hygienic mounting brackets
316L stainless lock nuts (2 pcs supplied with sensor)
المقاولين,قاطع الدائرة,الاستشعار,التشفير,بلك,محول















NH42-63-318x560.png)



