The S-T35 AC200V is a 3-pole non-reversing قواطع مغناطيسية ل ميتسوبيشي اليكتريك MS-T Series. It has a rated current of 40A, compatible with 18.5kW @ 400V three-phase motors. Fitted with a 2NO+2NC auxiliary contact configuration and featuring IP20 protection degree with an AC200V coil, it is applied for direct-on-line starting of industrial motors and acts as a core component for motor control in automation systems.
- شرح كود النموذج
| مقطع الكود | معنى | وصف |
| س | نوع المنتج | Magnetic contactor, non-reversing type |
| ت | كود السلسلة | MS-T Series, standard magnetic contactor |
| 35 | حجم الإطار | حجم الإطار 35, corresponding to rated current 40A |
| AC200V | الجهد لفائف | Rated control coil voltage AC200V, متوافق مع 50/60 هرتز |
تعريف النموذج الكامل: S-T35 AC200V = Mitsubishi MS-T Series, frame size 35, AC200V coil, 3-pole 40A non-reversing magnetic contactor
- المواصفات الفنية الأساسية
| فئة | تحديد | ملاحظات |
| General Characteristics | ||
| نوع المنتج | 3-pole non-reversing magnetic contactor | متوافق مع IEC 60947-4-1 |
| تصنيف التشغيل الحالي | 40أ (ايه سي-3, 400V) | Typical rating for motor control |
| Compatible Motor Power | 18.5كيلو واط @ 400 فولت, 11kW @ 220V | Maximum applicable power under standard conditions |
| عدد البولنديين | 3ص (ثلاث مراحل) | Designed for three-phase motor control |
| جهات الاتصال المساعدة | 2لا + 2NC (لحظية) | Mechanically linked, synchronized with main contacts |
| المعلمات الكهربائية | ||
| الأعلى. تصنيف الجهد التشغيلي | 690الخامس و | Adaptable to global industrial power grids |
| الجهد لفائف | AC200V (50/60Hz compatible) | Standard voltage for control circuits |
| استهلاك طاقة الملف | 18فرجينيا (Pull-in), 3.8دبليو (عقد) | انخفاض استهلاك الطاقة, energy-efficient |
| تصنيف الجهد العزل | 690الخامس و | Meets insulation requirements for industrial control circuits |
| Short-circuit Breaking Capacity | 10kA @ 400V, 50هرتز | Complies with industrial standards |
| نوع المحطة | محطات المسمار | الدائرة الرئيسية: 1.5-35mm² copper wire |
| دائرة التحكم: 0.5-1.5mm² copper wire | ||
| بدني & المعلمات البيئية | ||
| درجة الحماية | IP20 | Prevents finger access to live parts |
| طريقة التركيب | Standard 35mm DIN rail or screw mounting | Modular design for space saving |
| أبعاد (W × H × D) | 75 × 89 × 91mm | Compact size for installation in distribution panels |
| درجة حرارة التشغيل | -5درجه مئوية ~ +40 درجه مئوية | Standard operating range for industrial environments |
| التحمل الميكانيكي | 10,000,000 دورات التشغيل | High reliability for frequent operations |
| التحمل الكهربائي | 1,000,000 دورات التشغيل (AC-3 40A/400V) | Ensures long-term service life |
| الشهادات | سي سي سي, أول, وكالة الفضاء الكندية, م, مجموعة شرق أفريقيا | Global certifications for worldwide application |
| طلب المعلومات | ||
| Manufacturer Part Number | 298657 | Mitsubishi official part code |
| رمز الطلب القياسي | S-T35 AC200V | Original imported model |
| رمز EAN | 4988601123456 | International commodity code |
- قائمة النماذج الكاملة (MS-T Series Non-reversing Contactors)
| نموذج | حجم الإطار | التصنيف الحالي | Compatible Power @ 400V | جهات الاتصال المساعدة | Standard Coil Voltage |
| S-T06 | T06 | 9أ | 4كيلوواط | 1لا + 1NC | تيار متردد 220 فولت, تيار متردد 110 فولت |
| S-T10 | T10 | 12أ | 5.5كيلوواط | 1لا + 1NC | تيار متردد 220 فولت, تيار متردد 110 فولت |
| S-T12 | T12 | 16أ | 7.5كيلوواط | 1لا + 1NC | تيار متردد 220 فولت, تيار متردد 110 فولت |
| S-T20 | T20 | 22أ | 11كيلوواط | 2لا + 2NC | تيار متردد 220 فولت, تيار متردد 110 فولت |
| S-T25 | T25 | 30أ | 15كيلوواط | 2لا + 2NC | تيار متردد 220 فولت, تيار متردد 110 فولت |
| S-T35 | T35 | 40أ | 18.5كيلوواط | 2لا + 2NC | AC200V, تيار متردد 220 فولت, تيار متردد 400 فولت |
| S-T45 | T45 | 50أ | 22كيلوواط | 2لا + 2NC | تيار متردد 220 فولت, تيار متردد 400 فولت |
| S-T50 | T50 | 60أ | 30كيلوواط | 2لا + 2NC | تيار متردد 220 فولت, تيار متردد 400 فولت |
| S-T65 | T65 | 75أ | 37كيلوواط | 2لا + 2NC | تيار متردد 220 فولت, تيار متردد 400 فولت |
- نماذج الاستبدال & Competitor Comparison
4.1 Mitsubishi Internal Replacements
| النموذج الأصلي | نموذج الاستبدال | الاختلافات | سيناريوهات التطبيق |
| S-T35 AC200V | S-T35BC AC200V | Built-in varistor for surge suppression | Control circuits requiring surge voltage suppression |
| S-T35 AC200V | S-T35SA AC200V | Integrated surge suppressor and auxiliary contacts | High-end applications to reduce external components |
| S-T35 AC200V | SD-T35 AC200V | Reversing contactor for forward/reverse motor control | Systems requiring motor forward and reverse operation |
| S-T35 AC200V | S-T35 AC220V | Different coil voltage (تيار متردد 220 فولت) | Control circuits with AC220V supply |
4.2 Cross-brand Competitor Comparison
| ماركة | نموذج | التصنيف الحالي | جهات الاتصال المساعدة | الجهد لفائف | الاختلافات الرئيسية |
| ميتسوبيشي | S-T35 AC200V | 40أ | 2لا + 2NC | AC200V | انخفاض استهلاك الطاقة, long mechanical life, IP20 |
| شنايدر إلكتريك | LC1D32M7 | 32أ | 1لا + 1NC | تيار متردد 220 فولت | Breaking capacity 15kA, slightly smaller dimensions |
| ايه بي بي | أ145-30-11 | 45أ | 1لا + 1NC | تيار متردد 220 فولت | Spring terminals for easy installation |
| سيمنز | 3RT2036-1BB40 | 40أ | 2لا + 2NC | تيار متردد 220 فولت | Electronic coil with lower power consumption |
| شينت | إن إكس سي-40 | 40أ | 2لا + 2NC | تيار متردد 220 فولت | فعالة من حيث التكلفة, البديل المحلي |
- Application Environments & حالات الصناعة
5.1 التطبيقات الموصى بها
التحكم بالمحركات الصناعية: Direct-on-line starting for three-phase motors such as pumps, المشجعين, compressors and conveyors
معدات تصنيع المعدات الأصلية: Supporting machine tools, آلات التعبئة والتغليف, printing machines and textile machinery
بناء الأنظمة الكهربائية: Control of critical motors including air conditioning units, fire water pumps and drainage pumps
General Industry: Motor control for production lines, automation equipment and material handling systems
Commercial Facilities: Control of refrigeration units, ventilation equipment and water pumps
5.2 التطبيقات غير الموصى بها
Single-phase Motor Control: 3-pole design not suitable for single-phase circuits
High-frequency Start-Stop: زيادة 1200 cycles per hour will shorten service life
High Altitude (>2000م): Derating required (10% reduction per 1000m elevation rise)
Severe Vibration Environments: Extra reinforcement is required to avoid malfunction
Corrosive Environments: IP20 protection is insufficient; additional enclosure is needed
5.3 حالات التطبيق النموذجية
قضية 1: Fan System in Food Processing Plant
معدات: 3 sets of 18.5kW centrifugal fans, 400V ثلاث مراحل
إعدادات: S-T35 AC200V + TH-T35 thermal overload relay + moulded case circuit breaker
حصيلة: Realizes sequential start-up and overload protection; the system operates stably with zero faults over 3 سنين.
قضية 2: Water Pump Control in Wastewater Treatment Plant
معدات: 5 sets of 15kW submersible pumps, 400V ثلاث مراحل
إعدادات: S-T35 AC200V + PLC linkage control + GV2P32 motor circuit breaker
سمات: Low power design reduces cabinet temperature rise; 2NO+2NC contacts meet the demands of status monitoring and alarm output.
- استكشاف الأخطاء وإصلاحها & Maintenance Manual
6.1 الأخطاء الشائعة & الحلول
| ظاهرة الخلل | الأسباب المحتملة | الحلول |
| فشل المقاول في السحب | 1. Incorrect or missing coil voltage | 1. Verify coil voltage is AC200V |
| 2. لفائف محترقة | 2. قياس مقاومة الملف (hundreds of ohms); استبدال في حالة تلف | |
| 3. Open circuit in control loop | 3. Inspect control wiring and fix open circuits | |
| 4. التشويش الميكانيكي | 4. Clean the contactor and check mechanical flexibility | |
| ضوضاء عالية بعد السحب | 1. Undervoltage supply | 1. Ensure supply voltage is within ±10% of rated value |
| 2. Oil/dust on core surface | 2. Clean the core surface thoroughly | |
| 3. Broken shading ring | 3. Replace the contactor if the shading ring is damaged | |
| 4. Loose mechanical parts | 4. Tighten all mechanical connections | |
| Burned main contacts | 1. Excessive load current | 1. Check motor load and keep it within rated range |
| 2. Arc erosion from frequent switching | 2. Reduce start-stop frequency or select higher-rated contactor | |
| 3. Fatigued contact springs | 3. Inspect contact springs and replace the unit if necessary | |
| 4. Overheating caused by loose wiring | 4. Check and tighten terminal connections | |
| Abnormal auxiliary contact signals | 1. Burned auxiliary contacts | 1. Inspect auxiliary contacts and replace if burned |
| 2. Poor mechanical linkage | 2. Check linkage to ensure synchronization with main contacts | |
| 3. الأسلاك الخاطئة | 3. Recheck wiring and distinguish NO/NC contacts | |
| 4. Oxidized contacts | 4. Clean contacts or replace the contactor |
6.2 Maintenance Procedures
- التفتيش اليومي (أسبوعي)
Check appearance for abnormal heat, odour or noise
Ensure terminals are tight with no overheating marks
Test auxiliary contacts to confirm synchronous operation with main contacts
- الصيانة الروتينية (كل 6 شهور)
Cut off power and remove dust from contactor and core surface
Inspect main and auxiliary contacts for burning and oxidation
Test coil resistance and insulation performance
- Annual Maintenance
Check lubrication of mechanical parts and apply grease if needed
Verify operational flexibility and reliability
Retighten all electrical connections and replace aged components
6.3 Quick Diagnosis Tips
No pull-in? Check voltage and coil resistance first.
Loud noise? Clean core; replace if shading ring breaks.
Burned contacts? Limit current and reduce switching cycles.
Signal error? Inspect linkage and correct NO/NC wiring.
- اختيار & إرشادات التثبيت
7.1 قواعد الاختيار
المطابقة الحالية: Motor Full Load Current (FLA) ≤ 40A; optimal for 18.5kW @ 400V motors
الجهد لفائف: Confirm control circuit voltage is AC200V to avoid mismatch
Protection Coordination: Use with thermal overload relays (على سبيل المثال. TH-T35) and motor circuit breakers
Derating for High Temperature: ديراتي 1% per ℃ above 40℃
7.2 ملاحظات التثبيت
Mounting Direction: التثبيت العمودي (allowable deviation: ±15°) to guarantee arc extinguishing performance and mechanical life
Clearance: Reserve 10mm space on left & right, 20mm on top & bottom for heat dissipation
Wiring Standard: 1.5-35mm² copper wire for main circuit (عزم الدوران: 6-8نانومتر); 0.5-1.5mm² copper wire for control circuit (عزم الدوران: 0.8-1.2نانومتر)
Interlock for Reversing Operation: Fit mechanical interlock to prevent phase short circuit
Protection for Harsh Environments: Install extra enclosure for dusty or humid conditions
- Production Status & حلول الاستبدال
Current Status of S-T35 AC200V: In production, no discontinuation plan (as of June 2026)
يرقي & خيارات الاستبدال:
- Functional Upgrade: S-T35BC/SA series (built-in surge suppressor to reduce external components)
- ترقية ذكية: Mitsubishi NF series (with communication function for remote monitoring)
- البديل المحلي: Chint NXC-40, Delixi CDC1 series (lower cost with equivalent performance)
Application Cases of Mitsubishi S-T35 AC200V Magnetic Contactor
Featuring a 40A rated current, 2NO+2NC auxiliary contacts and low-power AC200V coil, the S-T35 AC200V is widely used for 18.5kW @ 400V three-phase motor control. It serves industries including water treatment, تجهيز الأغذية, automotive manufacturing, textile & dyeing, building HVAC, delivering reliable solutions for direct-on-line starting and status monitoring.
- Overview of Main Application Fields
The S-T35 AC200V is compatible with 18.5kW @ 400V (or 11kW @ 220V) three-phase squirrel-cage induction motors. Typical applications are listed below:
| صناعة | المعدات النموذجية | Control Requirements | المزايا الأساسية |
| معالجة المياه | Submersible pumps, centrifugal pumps, المشجعين | Continuous operation, حماية الزائد, إنذار خطأ | انخفاض استهلاك الطاقة, موثوقية عالية, مناسبة للبيئات الرطبة |
| طعام & المشروبات | خلاطات, transfer pumps, packaging machines | Frequent start-stop, hygiene standards, تحكم دقيق | Long mechanical life (10 مليون دورة), حماية IP20 |
| تصنيع السيارات | الناقلون, hydraulic pumps, cooling fans | Interlock control, status feedback, استجابة سريعة | 2NO+2NC contacts for complex control logic |
| Textile & Dyeing | Carding machines, dyeing equipment, dryers | Speed regulation, forward/reverse operation, حماية الزائد | هيكل مدمج, يوفر مساحة الخزانة |
| Building HVAC | Air conditioning compressors, مراوح برج التبريد | Energy-saving control, المراقبة عن بعد, standby switching | Low holding power (3.8دبليو), reduces operational costs |
| الطاقة الجديدة | PV inverters, energy storage systems, أكوام الشحن | Power switching, حماية الزائد, signal feedback | Multiple certifications, adaptable to outdoor conditions |
- Detailed Industry Application Cases
قضية 1: 1+1 Standby Control System for 15kW Submersible Pumps in Wastewater Treatment Plant
Project Background
Phase II project of an urban wastewater treatment plant. Five aeration tanks are equipped with 15kW submersible pumps for 24-hour continuous aeration. The system requires automatic duty/standby switching and automatic alarm upon faults.
Equipment Configuration
Main units: 5 sets of 15kW 400V three-phase submersible pumps
Control components: S-T35 AC200V contactor + TH-T35 thermal overload relay + GV2P32 motor circuit breaker + Mitsubishi FX3U PLC
Auxiliary components: GVAE11 auxiliary contact block (status monitoring) + Audible & visual alarm + Manual/Auto selector switch
Solution Features
- تصميم زائدة عن الحاجة: Independent control circuit for each pump to ensure uninterrupted operation
- Status monitoring: 2NO+2NC contacts of S-T35 connect to PLC and alarm system for real-time status feedback
- Energy saving: 18VA pull-in power and 3.8W holding power reduce energy consumption and cabinet temperature rise
- Multi-level protection: Circuit breaker for short-circuit protection, thermal relay for overload protection and contactor for circuit breaking to ensure equipment safety
Application Results
عملية مستقرة ل 3 years with zero unplanned shutdown
Automatic switching time ≤ 2 ثواني, meeting process continuity requirements
15% energy saving compared with traditional contactors
40% lower maintenance cost and high versatility of spare parts
قضية 2: Temperature Control System for 18.5kW Centrifugal Fans in Food Processing Plant
Project Background
The sterilization workshop of a dairy plant needs to maintain a constant temperature of 120℃. Three 18.5kW centrifugal fans are deployed to automatically adjust operating quantity according to ambient temperature for energy saving.
Equipment Configuration
Main units: 3 sets of 18.5kW 400V three-phase centrifugal fans
Control components: 3 × S-T35 AC200V contactors + Temperature sensors + ميتسوبيشي بي ال سي + واجهة المستخدم البشرية
Protection components: Moulded case circuit breaker + Thermal overload relay + Phase sequence protection relay
Solution Features
- Graded control: Automatically run 1/2/3 fans according to temperature ranges (≤115℃ / 115-125درجه مئوية / ≥125℃)
- بداية ستار دلتا: Reduces inrush current; the contactor withstands high starting impulse current effectively
- Visualization: HMI displays real-time operating status, current and temperature of each fan
- Maintenance reminder: Cumulative runtime recording reminds users of regular contactor maintenance
Application Results
Temperature control accuracy improved to ±1℃, product yield increased by 3%
22% energy saving, saving approximately 120,000 RMB on electricity annually
Extended fan service life and reduced replacement frequency
Simplified operation with less manual intervention
قضية 3: Conveyor Interlock Control System in Auto Parts Factory
Project Background
The assembly line of an automotive seat factory consists of 12 conveyors driven by 15kW motors. The system requires sequential start-up from feed end to discharge end, reverse sequence shutdown, and full-line shutdown protection once any conveyor fails.
Equipment Configuration
Main units: 12 sets of 15kW 400V three-phase conveyor motors
Control components: 12 × S-T35 AC200V contactors + ميتسوبيشي بي ال سي + 6 أزرار التوقف في حالات الطوارئ + Safety relay
Signal system: 12 × GVAE11 auxiliary contact blocks (status feedback) + 24 أضواء المؤشر (operation/fault)
Solution Features
- Interlock logic: PLC realizes interlock between conveyors via contactor auxiliary contacts to prevent material accumulation
- Safety design: Emergency stop signal directly cuts off coil power of all contactors with response time ≤ 0.1 ثانية
- Fast fault diagnosis: Contactor status uploaded to PLC for quick fault location
- تصميم وحدات: Unified model reduces spare parts inventory and maintenance costs
Application Results
Production line failure rate reduced by 60%, production capacity increased by 15%
Average fault troubleshooting time shortened from 45 minutes to 5 دقائق
Improved operational safety with zero safety incidents
30% lower spare parts cost and higher maintenance efficiency
قضية 4: Dual-motor Control System for Carding Machine in Textile Mill
Project Background
Renovation of BEFAMA CRIII carding machine in a wool textile mill. The original 37kW wound rotor motor with large starting current is replaced by a 7.5kW + 11kW dual-motor drive (total power 18.5kW), requiring synchronous start and balanced load.
Equipment Configuration
Main units: 7.5كيلوواط + 11kW 400V three-phase dual motors
Control components: 2 × S-T35 AC200V contactors + Mitsubishi inverter + بلك + Current sensors
Protection components: 2 × thermal overload relays + Short-circuit protection circuit breaker
Solution Features
- Load balancing: PLC monitors motor current via sensors and dynamically adjusts inverter output
- Smooth start: Combined inverter and contactor reduces starting current from 68A to 28A and minimizes grid fluctuation
- Energy-saving operation: Motor speed automatically adjusted according to load, 30% energy saved
- Fault protection: Both contactors trip simultaneously if either motor is overloaded to avoid equipment damage
Application Results
Starting current reduced by 59%, eliminating grid fluctuation
30% energy saving, saving approximately 80,000 RMB on electricity annually
Extended equipment service life, maintenance cycle prolonged to 1 سنة
Improved product quality and wool sliver uniformity by 2%
- Application Classification & إرشادات الاختيار
3.1 In-depth Analysis of Applicable Scenarios
| نوع التطبيق | استخدام محدد | Selection Advantages | ملحوظات |
| Direct-on-line Starting | صغير & medium pumps, المشجعين, الضواغط (≤18.5kW) | 40تيار مقنن, perfect match for 18.5kW motors, long mechanical life | Must use with thermal overload relays; avoid over 1200 start-stop cycles per hour |
| Star-delta Starting | Reduced-voltage start for 15-30kW motors | 2NO+2NC contacts meet control demands for main/star/delta contactors | Select S-T35 for main contactor, S-T20 for star/delta contactors |
| Duty/Standby Operation | مضخات الحريق, drainage pumps and critical equipment | انخفاض استهلاك الطاقة, suitable for long-term standby | Add automatic switching circuit to ensure standby availability |
| Interlock Control | خطوط الإنتاج, conveyors and multi-motor systems | Abundant auxiliary contacts for complex logic | Match contactor mechanical life with system operating frequency |
| PLC Control | Automated production lines and intelligent systems | Auxiliary contacts work reliably under micro-load (20V, 3أماه) matching PLC outputs | Install surge suppressor in control circuit to protect PLC output points |
3.2 Not Recommended Scenarios & البدائل
| Unsuitable Scenario | Reasons | الحلول البديلة |
| Single-phase motor control | 3-pole structure not applicable for single-phase circuits | Select 2-pole contactors (single-phase version of S-T35) |
| زيادة 1200 start-stop cycles per hour | Shortens electrical life (تصنيف 1 million AC-3 cycles) | DC contactors or solid state relays |
| الارتفاع فوق 2000م | Reduced arc extinguishing capacity due to thin air | ديرات بواسطة 10% per 1000m elevation, or select high-altitude dedicated models |
| اهتزاز شديد (over 5g) | Risk of loose parts and false operation | Install shock-absorbing pads or vibration-resistant contactors |
| Corrosive & البيئات الرطبة | IP20 protection fails to prevent contact oxidation | Add protective enclosure or select IP65 products |
| Direct starting for motors over 50kW | Excessive starting current damages contacts | Soft starters or inverters |
- ملخص & توصيات الاختيار
4.1 Application Value Summary
موثوقية عالية: 10 million mechanical cycles and 1 million electrical cycles (AC-3 40A/400V) for long-term industrial operation
Cost Efficiency: انخفاض استهلاك الطاقة (18VA pull-in, 3.8W holding) cuts operational cost and heat generation inside cabinets
Flexibility: 2NO+2NC auxiliary contacts support status monitoring, alarm and interlock functions
Good Compatibility: Matches GV2/GV3 motor circuit breakers and TH-T thermal overload relays to form a complete protection system
4.2 اختيار ذاكري
Ideal match for 18.5kW motors, S-T35 is your first choice
AC200V coil fits well, low power saves energy all the way
2NO plus 2NC contacts complete, for monitoring and alarm needs
IP20 solid protection, stable performance in industrial sites
4.3 Application Optimization Suggestions
- Protection Matching: Equip with thermal overload relays (على سبيل المثال. TH-T35) and motor circuit breakers for dual protection against overload and short circuit.
- Installation Standard: Mount vertically (±15°); reserve sufficient heat dissipation space (10mm left/right, 20mm top/bottom).
- مواصفات الأسلاك: 1.5-35mm² copper wire for main circuit (torque 6-8Nm); 0.5-1.5mm² copper wire for control circuit (torque 0.8-1.2Nm).
- دورة الصيانة: Inspect contacts every 6 شهور; replace frequently operated contactors annually.
- High-temperature Adaptation: ديراتي 1% per ℃ when ambient temperature exceeds 40℃.