انهيار رمز النموذج
H7EC-NFV
H7EC: مسلسل, compact panel-mounted self-powered total counter
ن: Totalizing counter (count-up only, no output contacts)
FV: Free Voltage Input AC/DC 24~240V (wide-range universal AC/DC signal input)
Suffix Distinction:
- Without suffix -B: Light gray housing; H7EC-NFV-B: Black housing of omron
- Without suffix -H: No backlight (standard configuration for this model); suffix -H denotes 24V backlight (this model has no backlight version)
- Core Basic Specifications
2.1 ميكانيكية & تصاعد
Standard cutout size: 1/32 DIN panel cutout 48mm(دبليو) × 24mm(ح)
الأبعاد الشاملة: 48(دبليو) × 24(ح) × 48.5(د) مم
تصاعد: Panel flush mounting, waterproof gasket supplied as standard; mounting bracket Y92F-34 available as an option
المحطات: 4-position screw terminals; wire-wrapping terminal kit Y92S-37 sold separately if required
2.2 Counting Performance
عرض: 8-digit LCD, digit height 8.6mm, full scale range 0~99999999
Counting mode: UP count only, no down-count function
Max counting frequency: 20هرتز, minimum input pulse width 25ms (duty ratio 1:1)
Reset methods: Manual reset button on unit + external terminal reset; reset response time 20ms
Key lock: Built-in DIP switch to lock manual reset and prevent accidental zeroing
2.3 مزود الطاقة (الميزة الأساسية: تعمل بالطاقة الذاتية, no external power required)
Built-in 3V lithium battery Y92S-36; count data retained permanently after power loss
Battery service life: تقريبا. 6–8 years continuous display at ambient temperature; battery can be replaced individually when exhausted
No external operating power needed; only count/reset signals of AC/DC 24~240V can be connected
2.4 FV Free Voltage Input Specifications (المعلمات الرئيسية)
Directly compatible with AC contactors, relay contacts, 220V photoelectric sensors and high-voltage proximity switches
High Level (ح): AC/DC 24~240V (recognized as valid count signal)
Low Level (ل): AC/DC 0~2.4V (no counting triggered when disconnected)
Input current: تقريبا. 4.3mA at AC264V; تقريبا. 2.9mA at DC24V
Compatible signals: Relay contacts, AC sensors, 220V transistor outputs
2.5 الشهادات & التقييمات البيئية
الشهادات: م, UL508, وكالة الفضاء الكندية, EN61010-1
درجة حرارة التشغيل: -10℃ to +55℃, no condensation allowed
Front panel protection rating: IP65 (when fitted with supplied waterproof gasket)
- Terminal Definition & مخطط الأسلاك
4 terminals arranged left to right: 1, 2 (Count Input) | 3, 4 (Reset Input)
3.1 Standard Wiring for Relays / AC Contacts
Count signal: Parallel the normally open contacts of AC contactors or relays across terminals 1 و 2
External reset: Parallel reset switch or reset relay contacts across terminals 3 و 4
> Polarity-free, compatible with both AC and DC signals
3.2 Wiring for High-Voltage NPN/PNP Sensors
Connect sensor output directly to terminals 1 و 2, connect the 0V common line to the opposite terminal; compatible with AC/DC signals ranging from 24V to 220V
- Comparison of Same Series Models (Model Selection Reference)
| نموذج | نوع الإدخال | Max Count Frequency | الإضاءة الخلفية | تطبيق نموذجي |
| H7EC-NFV | Wide-range AC/DC 24~240V | 20هرتز | لا أحد | 220V relays, AC photoelectric sensors, high-voltage signals from legacy equipment |
| H7EC-NV | DC dedicated PNP/NPN 4.5~30V | Switchable 30Hz / 1كيلو هرتز | Optional with -H suffix | 24V DC sensors, encoders |
| H7EC-N | Voltage-free contact input (الاتصال الجاف) | Switchable 30Hz / 1كيلو هرتز | لا أحد | Mechanical contacts, dry contacts, limit switches |
- سيناريوهات التطبيق النموذجية
- Cumulative production counting for assembly line equipment (direct connection of 220V AC photoelectric sensors without intermediate relays)
- Operation cycle counting for fans and water pumps (driven by auxiliary contactors)
- Total stroke recording for injection molding machines and stamping presses
- Counting matched with legacy 220V-output sensors, eliminating the need for voltage conversion modules
- مُكَمِّلات & Consumables
- Replacement lithium battery: Y92S-36 3V
- Flush mounting bracket: Y92F-34
- Waterproof sealing gasket: Included as standard
- Wire-wrapping terminal kit: Y92S-37 (converts screw terminals for wire-wrap wiring)
- احتياطات العملية
- Never apply input voltage exceeding AC/DC 240V, otherwise the internal input circuit will be damaged
- This model supports low-speed counting at 20Hz; select H7EC-NV (1kHz high-speed model) for high-frequency pulses (>20 pulses per second)
- Activate the key lock if the unit will be idle for a long period to avoid accidental reset; lock function controlled via DIP switch on unit side
- The LCD display will disappear when the lithium battery is exhausted, but stored count data remains intact; display resumes after battery replacement
- No relay output function; this unit only provides cumulative readout. Select H7CX series counters if output triggering upon preset value is required
- Replacement Alternatives
- Direct drop-in replacement with identical specs: H7EC-NFV-B (black housing, fully identical electrical parameters)
- Upgraded replacement for DC signal applications: H7EC-NV (supports 1kHz high-speed counting, suitable for 24V encoders)
- Replacement with control output function: H7CX-A/N (with preset alarm output, requires external power supply)
OMRON H7EC-NFV Temperature Specifications
- درجة حرارة التشغيل المحيطة (Running Temperature)
-10℃ ~ +55℃
Restriction: No ice formation or condensation permitted in surroundings
- درجة حرارة التخزين (Powered-off Storage)
-25℃ ~ +65℃
Ice and condensation are also prohibited under storage conditions
Supplementary Humidity Requirements
Operating humidity: 25%~85%RH, لا التكثيف
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية