ال Schmersal SRB301MC-24V is a high-performance safety relay module. وتشمل مزاياها الأساسية 3 اتصالات السلامة زائد 1 إخراج الإشارة, قف 0 فئة التوقف, مستوى الأداء ه (بل ه) والتغطية التشخيصية ≥99%. It is widely deployed in safety protection systems for various industrial automation equipment. Featuring a dedicated design for magnetic safety switches and cross-wire detection function, it delivers outstanding performance in safety gate monitoring applications. Please check compatibility with safety input devices during model selection, and strictly follow wiring specifications during installation to ensure safe and reliable system operation.
- شرح كود النموذج
The SRB301MC-24V is a safety relay module of the PROTECT SRB series manufactured by Schmersal, ألمانيا. The breakdown of the model code is as follows:
| مقطع الكود | تعريف |
| SRB | رمز السلسلة: Safety Relay Block |
| 301 | Function code: 3 safety contacts and 1 إخراج الإشارة, compatible with single/dual-channel safety inputs |
| مولودية | Characteristic code: Designed for signals from BNS series magnetic safety switches, supports cross-wire detection |
| 24V | تصنيف جهد التشغيل: 24الخامس التيار المتناوب/تيار مستمر, compatible with AC and DC power supply |
Order Numbers: 101190684 (الإصدار القياسي), 161190684 (International Version), 151190684 (China Version)
- Main Technical Specifications
| فئة | البيانات الفنية | ملاحظات |
| General Specifications | ||
| يكتب | Safety monitoring module, emergency stop safety relay | قف 0 فئة التوقف |
| جهد التشغيل | 24الخامس و (-15%/+10%) / 24في العاصمة (-15%/+40%) | Maximum ripple voltage: 10% |
| استهلاك الطاقة | 2دبليو | تصميم منخفض استهلاك الطاقة |
| حماية الدخول | IP20 (المحطات) / IP40 (Housing) | Suitable for control cabinet installation |
| خصائص الإدخال | ||
| Monitoring Channels | Switchable single/dual channel | Cross-wire detection supported |
| نوع الإدخال | Passive contacts / Active signals (AOPDs) | Compatible with safety light curtains, أزرار التوقف في حالات الطوارئ, إلخ. |
| المدخلات الحالية | >500أماه | Reset time of monitoring circuit: تقريبا. 1 ثانية |
| خصائص الإخراج | ||
| اتصالات السلامة | 3 اتصالات (2نورث كارولاينا + 1لا) | DC13: 24V/6A; AC15: 230V/6A |
| إخراج الإشارة | 1 اتصال مساعد | For status indication or alarm |
| مستوى الأداء | بل ه (Highest level) | Compliant with EN ISO 13849-1 |
| Safety Category | فئة 4 | Compliant with EN IEC 61508 |
| Diagnostic Coverage | ≥99% | High reliability design |
| الخصائص البدنية | ||
| أبعاد | 22.5mm × 100mm × 121mm | تركيب السكك الحديدية DIN, توفير المساحة |
| تصاعد | 35مم السكك الحديدية DIN القياسية | Standard industrial mounting |
| درجة حرارة التشغيل | -25°C ~ 60°C | نطاق درجة حرارة واسعة للبيئات الصناعية |
| المحطات | محطات المسمار | Cable cross-section: 0.25mm² ~ 2.5mm² |
| الشهادات | BG, أول, وكالة الفضاء الكندية, م | متوافقة مع معايير السلامة الدولية |
- Cross-Brand Compatibility List
| ماركة | نموذج الاستبدال | وصف التوافق |
| Schmersal | SRB E 301MC-24V (103014374) | Enhanced replacement, fully compatible with improved performance |
| سيمنز | 3SK1111-1AB30 | Equivalent safety relay, 3 اتصالات السلامة, 24في العاصمة |
| شنايدر | XPSAC5121 | 24الخامس التيار المتناوب/تيار مستمر, 3 safety contacts and 1 إخراج الإشارة |
| اومرون | G9SA-321-T075 | 24في العاصمة, 3 اتصالات السلامة, قف 0 فئة التوقف |
| ايه بي بي | MSR132TP | 24الخامس التيار المتناوب/تيار مستمر, 3 اتصالات السلامة, single/dual channel |
Selection Guideline: Match voltage and contact quantity; do not downgrade safety performance level; keep identical mounting dimensions.
- Full Model List of SRB Series
| نموذج | الجهد االكهربى | تكوين الاتصال | وظائف خاصة | رقم الطلب |
| SRB301MC-24V | 24الخامس التيار المتناوب/تيار مستمر | 3 أمان (2NC+1NO) + 1 إشارة | For magnetic switches, cross-wire detection | 101190684 |
| SRB301MC-24V-STSS | 24الخامس التيار المتناوب/تيار مستمر | 3 أمان (2NC+1NO) + 1 إشارة | حماية ماس كهربائى, for magnetic switches | 101190685 |
| SRB301-24V | 24الخامس التيار المتناوب/تيار مستمر | 3 أمان (2NC+1NO) + 1 إشارة | General type, no optimization for magnetic switches | 101190686 |
| SRB302MC-24V | 24الخامس التيار المتناوب/تيار مستمر | 4 أمان (3NC+1NO) + 1 إشارة | Dual-gate monitoring, for magnetic switches | 101190687 |
| SRB301MC-110V | 110الخامس و | 3 أمان (2NC+1NO) + 1 إشارة | For magnetic switches, high voltage version | 101190688 |
| SRB301MC-230V | 230الخامس و | 3 أمان (2NC+1NO) + 1 إشارة | For magnetic switches, high voltage version | 101190689 |
- الأخطاء الشائعة & استكشاف الأخطاء وإصلاحها
| ظاهرة الخلل | الأسباب المحتملة | الحلول |
| مؤشر الطاقة مطفأ | 1. Power disconnected or abnormal voltage | 1. Check power connection and voltage (20.4V~28.8V) |
| 2. Internal fuse blown | 2. Replace 2A internal fuse | |
| Safety contacts fail to operate | 1. Abnormal input signal | 1. Inspect safety input devices (أوقف, light curtains, إلخ.) |
| 2. Incorrect cross-wire detection setting | 2. Adjust QS switch (قمة: cross-wire protection off; قاع: cross-wire protection on) | |
| 3. Damaged contacts | 3. Replace the safety relay module | |
| No signal output | 1. Safety circuit not reset | 1. Check reset conditions (manual/automatic reset) |
| 2. Damaged signal output contacts | 2. Test continuity of signal contacts | |
| التعثر الكاذب المتكرر | 1. Electromagnetic interference | 1. Add shielding and keep away from interference sources |
| 2. Poor cable connection | 2. Recheck cable connections | |
| 3. درجة الحرارة المحيطة خارج النطاق | 3. Ensure temperature within -25°C ~ 60°C |
Check power first, then inputs; wrong settings are common causes; watch out for interference and reset requirements.
- Application Environments & حالات الصناعة
6.1 السيناريوهات القابلة للتطبيق
Machinery Safety Protection: Emergency stop systems for injection molding machines, punch presses, press brakes and other stamping equipment
Automation Production Lines: Signal processing for safety light curtains to prevent personnel from entering hazardous areas
اللوجستية & التخزين: Safety gate monitoring for stackers and conveyors with BNS magnetic safety switches
ماكينات التعبئة والتغليف: Safety interlock for filling and labeling machines to ensure operational safety
Automotive Manufacturing: Safety zone monitoring for welding robots and coating lines
6.2 Not Recommended Scenarios
Harsh outdoor environments: IP20 protection rating is not suitable for outdoor installation
Highly corrosive environments: No anti-corrosion coating, incompatible with acid, alkali and corrosive media
High vibration environments: Vibration over 5g may shorten relay service life
High temperature over 60°C: Will degrade performance and service life
6.3 حالات التطبيق
قضية 1: Stamping Production Line for Automotive Parts
طلب: Emergency stop system and signal processing of safety light curtains for 3 punch presses
إعدادات: One SRB301MC-24V installed on each press, connected with emergency stop buttons and safety light curtains
تأثير: Realizes instant STOP 0 shutdown with diagnostic coverage ≥99%, reducing safety risks
قضية 2: Safety System for Food Packaging Machinery
طلب: Safety gate monitoring for filling and capping machines with Schmersal BNS magnetic safety switches
إعدادات: SRB301MC-24V monitors 2 safety gates; cross-wire detection prevents cable failures
تأثير: Complies with food industry safety standards and improves equipment reliability
قضية 3: Stackers in Automated Warehouse
طلب: Safety gate monitoring and emergency stop system for stacker aisles
إعدادات: SRB301MC-24V connected to magnetic safety switches and E-stop buttons; signal output linked to PLC
تأثير: Stacker is locked when safety gates are open, upgrading warehouse safety level
Detailed Application Cases of Schmersal SRB301MC-24V Safety Relay
This model is optimized for magnetic safety switches, dual-channel monitoring and cross-wire detection, compliant with PL e / فئة 4. It is widely used for safety gates, emergency stops and safety light curtains. Below are practical industry cases including wiring schemes, operation methods and application values.
- Machine Tool Industry (التطبيق الرئيسي)
قضية 1: بوابة الأمان & E-Stop Interlock for CNC Punch Press / Press Brake
- أجهزة المطابقة: Schmersal BNS magnetic safety switches (machine protective gates) + Mushroom-head emergency stop buttons
- عملية:
Adopt dual-channel input and cross-wire detection to monitor front and rear protective gates;
Safety contacts open immediately when gates are opened or E-stop is triggered, executing STOP 0 instant shutdown;
Auxiliary signal contacts connect to PLC for gate status and fault alarm upload.
- قيمة: Prevent personnel from accessing stamping hazardous areas; detect cable breakage and short circuit to avoid safety failure.
قضية 2: Rotating Hatch Monitoring for Machining Centers
- أجهزة المطابقة: BNS magnetic safety switches (rotating protective gates)
- عملية: Switchable single/dual channel; equipment cannot start if gates are not fully closed; power circuit cuts off immediately if gates are opened during operation.
- Applicable Equipment: Vertical machining centers, drilling & milling machines, المطاحن.
- Automation Production Lines & الروبوتات
قضية 1: Safety Fence Monitoring for Robot Workcells
- أجهزة المطابقة: Magnetic safety switches (fence access gates) + Safety light curtains
- عملية:
Signals from safety gates and light curtains are wired in series to the relay;
Robot stops and locks when personnel intrude or gates are opened; on-site reset is required for restart.
- السيناريوهات النموذجية: Automotive component handling, welding robots, loading/unloading robot cells.
قضية 2: Centralized Emergency Stop Control for Production Lines
- عملية: Emergency stop buttons at multiple workstations are connected in parallel to the module, cutting off power of motors and conveyors via unified safety circuit.
- المزايا: Fast response and powerful circuit diagnosis, ideal for full-line safety interlock.
- التعبئة والتغليف, طعام & Pharmaceutical Machinery
قضية 1: Guard Safety Protection for Automatic Filling & Sealing Machines
- أجهزة المطابقة: BNS non-contact magnetic safety switches (movable machine guards)
- عملية:
Frequent opening/closing of guards in food equipment leads to no mechanical wear for magnetic switches and longer service life;
Enable cross-wire detection to avoid safety hazards caused by aging and short-circuited cables in humid environments.
- Applicable Equipment: Beverage fillers, daily chemical packaging machines, pharmaceutical blister packaging machines.
قضية 2: Access Gate Interlock for Carton Packaging & Palletizing Machines
Magnetic switches are installed on equipment access gates. The palletizing mechanism and conveyors lock completely once gates are opened, protecting maintenance personnel.
- اللوجستية & Warehousing Equipment
قضية 1: Aisle Safety Gate Monitoring for Warehouse Stackers
- Monitoring Points: Protective gates and access gates of stacker travel aisles
- Logic: Stacker is disabled for travelling and lifting when gates are open; immediate shutdown and alarm during operation.
- ميزة: Cross-wire detection effectively diagnoses faults of long-distance cables in warehousing systems.
قضية 2: Zone Safety Protection for Belt / Roller Conveyors
Access gates on both sides of conveyors and line-mounted E-stop buttons are connected to the module, realizing full-section emergency stop. Widely used in express sorting and material conveying lines.
- Rubber, Plastic & Injection Molding Machinery
قضية: بوابة الأمان & Mold Area Protection for Injection Molding Machines
- أجهزة المطابقة: Magnetic safety switches (أمام & rear safety gates of injection machines)
- عملية: Mold opening and part picking areas are high-risk zones. Mold closing action is locked when gates are opened to prevent pinching accidents. Complies with national safety standards for rubber & plastic machinery.
- General Auxiliary Applications (Small Equipment & Control Cabinets)
قضية: Small Automated Tooling & Test Equipment
For various custom assembly and test tooling, this relay builds cost-effective high-level safety circuits (فئة 4 / بل ه) with single E-stop and simple protective gates, suitable for small and medium-sized custom equipment.
Supplementary Operation Notes
- For optimal performance, use with Schmersal BNS magnetic safety switches (original manufacturer recommended combination).
- Enable cross-wire detection for long-distance wiring, humid or dusty sites.
- All above applications meet EN ISO 13849 PL e and Category 4, acceptable for equipment exported to the EU.
- Not recommended for outdoor, highly corrosive or severe vibration environments. IP40 rating is only for indoor control cabinet installation.